Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- NextDent [TM] Base, NextDent [TM ] SG, NextDent [TM ] Ortho Rigid, NextDent [TM ] Tray, NextDent [TM ] C&B
- Synonyms
- Base, SG, Ortho Rigid, Tray, C&B
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Base: Monomer based on acrylic esters for manufacturing of 3D-printed denture bases. SG: Monomer based on acrylic esters for manufacturing of 3D-printed surgical guides. Ortho Rigid: Monomer based on acrylic esters for manufacturing of 3D-printed dental splints. Tray: Monomer based on acrylic esters for manufacturing of 3D-printed individually impression trays. C&B: Monomer based on acrylic esters for manufacturing of 3D-printed crowns and bridges.
Uses advised against
Mixtures containing unreacted liquid monomer intended to come into contact with skin or nails.
Manufacturers & Suppliers
Vertex-Dental B.V.
PO Box 10 3700 AA Zeist The Netherlands
www.vertex-dental.com
Emergency Contacts
Vertex-Dental B.V.
+31 88 616 04 40
only available during office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Substances in the product which may present a health or environmental hazard, or which have been assigned occupational exposure limits, are detailed below. According to Regulation (EG) Nr. 1272/2008 [CLP].
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | 60% | Yes |
| N/A | --- | 15 - 25% | Yes |
| N/A | --- | 2.5% | Yes |
| N/A | --- | 2.5% | Yes |
Notes
For full text of H phrases see section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move into fresh air and keep at rest. Get medical attention if any discomfort continues.
Remove contaminated clothing immediately and wash skin with soap and water. Get medical attention promptly if irritation or other symptoms occur after washing.
Continue to rinse for at least 15 minutes under running water with eyelids held open. Get medical attention if any discomfort continues.
Do not induce vomiting. Immediately rinse mouth and drink plenty of water. Get medical attention if any discomfort continues
Immediate Medical Attention
Note to physician. Treat according to symptoms (decontamination, vital functions).
Medical Treatment
Treat according to symptoms (decontamination, vital functions).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
NextDent SG Orange
---
NextDent Gingiva Mask
---
NextDent 3D printing materials
---
Vertex Implacryl, Vertex Regular, Vertex Rapid Simplified, Vertex BasiQ20, Holland Dental Implacryl, Holland Dental Rapid Simplified
---
Dentsply DURR Orotol Plus
---
Ortho Solo, Ortho Solo Stick
---
Ortho BioVue System (ABD Confirmation Cassette)/Ortho BioVue System (ADK Cassette)
---
VeroWhitePlus, RGD835
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded.
Wear suitable gloves. Butyl and nitrile rubber gloves offer short-term protection. Gloves should be stored correctly and changed regularly, especially if excessive exposure has occurred.
Wear eye/face protection. Wear approved chemical safety goggles where eyes exposure must be provided.
Wear suitable respiratory protective equipment if engineering controls are insufficient, or not present, and exposure to levels above the DNEL is likely. A suitable mask with filter type P2 may be appropriate.
Keep working clothes separately. Take off contaminated clothing immediately. Wash soiled clothing before reuse.
Ensure effective control measures when working within the boundaries as specified in section 6.2 of each GES.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is NextDent [TM] Base, NextDent [TM ] SG, NextDent [TM ] Ortho Rigid, NextDent [TM ] Tray, NextDent [TM ] C&B known by?
NextDent [TM] Base, NextDent [TM ] SG, NextDent [TM ] Ortho Rigid, NextDent [TM ] Tray, NextDent [TM ] C&B is also known as: Base, SG, Ortho Rigid, Tray, C&B
What is the hazard signal word for NextDent [TM] Base, NextDent [TM ] SG, NextDent [TM ] Ortho Rigid, NextDent [TM ] Tray, NextDent [TM ] C&B?
The signal word is warning.
What is the solubility of NextDent [TM] Base, NextDent [TM ] SG, NextDent [TM ] Ortho Rigid, NextDent [TM ] Tray, NextDent [TM ] C&B?
Good solubility with most organic solvents
What is NextDent [TM] Base, NextDent [TM ] SG, NextDent [TM ] Ortho Rigid, NextDent [TM ] Tray, NextDent [TM ] C&B used for?
Base: Monomer based on acrylic esters for manufacturing of 3D-printed denture bases. SG: Monomer based on acrylic esters for manufacturing of 3D-printed surgical guides. Ortho Rigid: Monomer based on acrylic esters for manufacturing of 3D-printed dental splints. Tray: Monomer based on acrylic esters for manufacturing of 3D-printed individually impression trays. C&B: Monomer based on acrylic esters for manufacturing of 3D-printed crowns and bridges.
What are the hazard statements for NextDent [TM] Base, NextDent [TM ] SG, NextDent [TM ] Ortho Rigid, NextDent [TM ] Tray, NextDent [TM ] C&B?
This substance has 2 hazard statements:
- H317: May cause an allergic skin reaction.
- H413: May cause long-lasting harmful effects to aquatic life.
What is the melting point of NextDent [TM] Base, NextDent [TM ] SG, NextDent [TM ] Ortho Rigid, NextDent [TM ] Tray, NextDent [TM ] C&B?
The melting point is Not applicable and the boiling point is - 200C.