NextSDS Logo
AR

ARBOCEL B xx ZS

NO SIGNAL WORD Powder SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ARBOCEL B xx ZS

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
The product is intended for professional use.
Uses Advised Against
not relevant

Overview

ARBOCEL B xx ZS commonly used the product is intended for professional use..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

J. RETTENMAIER & SHNE GMBH + CO KG company logo - Safety Data Sheet supplier organization

J. RETTENMAIER & SHNE GMBH + CO KG

manufacturer

๐Ÿ“

Holzmhle 1 D 73494 Rosenberg Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 7967 152 0

๐Ÿ“ 

+49 7967 152 222

๐ŸŒ www.jrs.de

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 7967 152 199

๐ŸŒ

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Cellulose
EC: 232-674-9
9004-34-6 90% โœ“ Non-hazardous
Citric acid
EC: 201-069-1
77-92-9 10% โš ๏ธ Hazardous

Additional Information

The substance does not require registration according to REACH.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Provide fresh air. When in doubt or if symptoms are observed, get medical advice.

๐Ÿ–๏ธ Skin Contact

After contact with skin, wash immediately with plenty of water and soap. In case of skin irritation, consult a physician.

Symptoms:

Skin irritation.

๐Ÿ‘๏ธ Eye Contact

In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist.

Symptoms:

Irritating to eyes.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth immediately and drink plenty of water. When in doubt or if symptoms are observed, get medical advice.

๐Ÿšจ Immediate Medical Attention Required

Treat symptomatically.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Powder
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
white
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
characteristic
๐Ÿ“Š Odor Threshold
not relevant
๐Ÿงช Ph
~ 2
๐ŸงŠ Melting Point
not applicable
Critical Property
๐Ÿ’จ Boiling Point
not applicable
Critical Property
๐Ÿ”ฅ Flash Point
not determined
Critical Property
๐Ÿ“Š Freezing Point
not applicable
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
not applicable
๐Ÿ’จ Vapor Pressure
not applicable
๐Ÿ“Š Vapor Density
not applicable
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
100 - 260 g/L
โš–๏ธ Density
not determined
Critical Property
๐Ÿ”ฅ Flammability
not relevant
๐Ÿ“Š Upper Explosive Limit
no data available
๐Ÿ“Š Lower Explosive Limit
30 g/m no data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
~ 500 C Godbert-Greenwald
๐Ÿ“Š Decomposition Temperature
~ 170 C
๐Ÿ’ง Solubility
not relevant
๐Ÿ“Š Partition Coefficient
no data available
๐Ÿ“Š Solubility In Water
partially soluble
๐Ÿ“Š Solubility In Fat
insoluble
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

If technical exhaust or ventilation measures are not possible or insufficient, respiratory protection must be worn.

๐Ÿงค Hand Protection

Suitable material: CR (polychloroprene, chloroprene rubber). Thickness of the glove material: 0.5 mm. Breakthrough time (maximum wearing time): 8 h. Suitable material: NBR (nitrile rubber). Thickness of the glove material: 0.35 mm. Breakthrough time (maximum wearing time): 8 h. Suitable material: BR (butyl rubber). Thickness of the glove material: 0.5 mm. Breakthrough time (maximum wearing time): 8 h. Suitable material: FKM (fluorine rubber). Thickness of the glove material: 0.4 mm. Breakthrough time (maximum wearing time): 8 h. Suitable material: PVC (poly vinyl chloride). Thickness of the glove material: 0.5 mm. Breakthrough time (maximum wearing time): 8 h.

๐Ÿ‘๏ธ Eye Protection

Eye glasses with side protection

๐Ÿ˜ท Respiratory Protection

Suitable respiratory protection apparatus: Combination filtering device (DIN EN 141). Filter class: A-P2. The filter class must be suitable for the maximum contaminant concentration (gas/vapour/aerosol/particulates) that may arise when handling the product. If the concentration is exceeded, self-contained breathing apparatus must be used!

๐Ÿฆบ Skin/Body Protection

Avoid contact with skin, eyes and clothes.

๐ŸŒ Environmental Exposure Controls

Do not allow to enter into surface water or drains.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ARBOCEL B xx ZS?

The signal word for this substance is "no signal word".

What is the physical form of ARBOCEL B xx ZS?

ARBOCEL B xx ZS is a powder with white color. It has characteristic odor.

What is the solubility of ARBOCEL B xx ZS?

not relevant

What is ARBOCEL B xx ZS used for?

The product is intended for professional use.

What is the melting point of ARBOCEL B xx ZS?

The melting point is not applicable and the boiling point is not applicable.