NextSDS Logo
TO

TOTAL RENEWABLE DIESEL

DANGER Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
TOTAL RENEWABLE DIESEL
Product Form
Substance

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial use,Professional use, Manufacture of substances, Distribution of substance, Formulation & (re)packing of substances and mixtures, Intermediates, Use in laboratories, Water treatment., Coating, Cleaner, Lubricant, Use in metal working fluids/rolling oils, Use as binders and release agents, Use in functional fluids, Polymers, Use in Oil field drilling and production operations, Use in mining chemicals, Use in road and construction products, Use in explosives, Use in Agrochemicals, Use as a fuel.
Uses Advised Against
No additional information available

Overview

TOTAL RENEWABLE DIESEL commonly used industrial use,professional use, manufacture of substances, distribution of substance, formulation & (re)packing of substances and mixtures, intermediates, use in laboratories, water treatment., coating, cleaner, lubricant, use in metal working fluids/rolling oils, use as binders and release agents, use in functional fluids, polymers, use in oil field drilling and production operations, use in mining chemicals, use in road and construction products, use in explosives, use in agrochemicals, use as a fuel..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Asp. Tox. Category 1 H304

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H304: May be fatal if swallowed and enters airways.

Precautionary Statements

  • P273: Avoid release to the environment.
  • P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
  • P314: Get medical advice/attention if you feel unwell.
  • P403+P233: Store in a well-ventilated place. Keep container tightly closed.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

TOTAL RAFFINAGE FRANCE company logo - Safety Data Sheet supplier organization

TOTAL RAFFINAGE FRANCE

manufacturer

๐Ÿ“

92078 PARIS LA DEFENSE - FRANCE

๐ŸŒ

FR

๐Ÿ“ž

+33 (0)1.41.35.40.00

๐ŸŒ www.total.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Carechem 24 International

๐Ÿ“ž

+44 (0) 1235 239 670

๐ŸŒ

GB

๐Ÿ—ฃ๏ธ

Languages: EN

Carechem 24 International

๐Ÿ“ž

+ 33 1 49 00 00 49

๐ŸŒ

FR

Carechem 24 International

๐Ÿ“ž

+ 44 (0) 1235 239 671

๐ŸŒ

GB

Carechem 24 International

๐Ÿ“ž

400 120 6011

๐ŸŒ

CN

Carechem 24 International

๐Ÿ“ž

+ 65 3158 1074

๐ŸŒ

SG

National Poisons Information Centre

๐Ÿ“ž

+353 1 809 2566

๐ŸŒ

IE

๐Ÿ•’

(Healthcare professionals24/7)

National Poisons Information Centre

๐Ÿ“ž

+353 1 809 2166

๐ŸŒ

IE

๐Ÿ•’

(public, 8am - 10pm, 7/7)

National Poisons Emergency number

๐Ÿ“ž

08 45 46 47

๐ŸŒ

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

UVCB

General Composition

TOTAL RENEWABLE DIESEL

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Renewable hydrocarbons (diesel type fraction)
EC: 942-445-1
N/A Not specified โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention if you feel unwell.

๐Ÿ–๏ธ Skin Contact

Wash with plenty of soap and water. Exposure to splashing of hot product: Treat the affected part with cold water (by spraying or immersion).

๐Ÿ‘๏ธ Eye Contact

Immediately rinse with water for a prolonged period while holding the eyelids wide open.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not give anything to drink. Do not induce vomiting. If swallowed, rinse mouth with water (only if the person is conscious).

๐Ÿšจ Immediate Medical Attention Required

Get medical advice/attention if you feel unwell. Obtain medical attention if irritation persists. Treat symptomatically.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Pale.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Mild.
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
No data available
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
180 320 C (1013 hPa)
Critical Property
๐Ÿ”ฅ Flash Point
> 60 C (1013 hPa)
Critical Property
๐Ÿ“Š Freezing Point
No data available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
No data available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
< 0.01 hPa (20C)
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
No data available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
770 800 kg/m (15C)
Critical Property
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
insoluble in water.
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
insoluble in water.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
No data available
๐Ÿ“Š Kinematic Viscosity
2 5 mm/s (40C)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure adequate ventilation. Safety shower. Eye fountain.

๐Ÿงค Hand Protection

hydrocarbons resistant gloves. In case of repeated or prolonged contact wear gloves. recommended material: fluorinated polymer. polyvinyl alcohol. Layer thickness : all thicknesses. Breakthrough time : > 480 min. EN 374-3. In the event of contact with the liquid: Nitrile rubber gloves. Layer thickness : > 0,30 mm. Breakthrough time : > 60 min. EN 374-3. Gloves may degrade in contact with this chemical. - Carefully check the glove for cracks or damage before reusing it, dispose of gloves where the penetration time is exceeded. The penetration time depends on temperature, glove material, thickness and construction. Penetration time is measured against EN 374 in laboratory conditions corresponding to permanent static contact and is not necessarily representative of the risk in the workplace. Contact the gloves' supplier for further information on the selection and resistance of gloves.

๐Ÿ‘๏ธ Eye Protection

Safety glasses. Do not wear contact lenses

๐Ÿ˜ท Respiratory Protection

Ensure good ventilation of the work station. Do not breathe gas, fumes, vapour or spray. Air-fed respiratory protective equipment should be worn when this product is sprayed if the exposure of the sprayer or other people nearby cannot be controlled to below the occupational exposure limit. In case of over-exposure or in confined areas : Wear respiratory protection. Filter A

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing. Safety foot-wear

๐ŸŒ Environmental Exposure Controls

Avoid release to the environment. Assure that emissions are compliant with all applicable air pollution control regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 1202

๐Ÿ“ฆ Proper Shipping Name

DIESEL FUEL

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

V12

๐Ÿšข IMDG Maritime Transport Precautions

363

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for TOTAL RENEWABLE DIESEL?

The signal word for this substance is "danger".

What is the physical form of TOTAL RENEWABLE DIESEL?

TOTAL RENEWABLE DIESEL is a liquid with pale. color. It has mild. odor.

What is the solubility of TOTAL RENEWABLE DIESEL?

insoluble in water.

What is TOTAL RENEWABLE DIESEL used for?

Industrial use,Professional use, Manufacture of substances, Distribution of substance, Formulation & (re)packing of substances and mixtures, Intermediates, Use in laboratories, Water treatment., Coating, Cleaner, Lubricant, Use in metal working fluids/rolling oils, Use as binders and release agents, Use in functional fluids, Polymers, Use in Oil field drilling and production operations, Use in mining chemicals, Use in road and construction products, Use in explosives, Use in Agrochemicals, Use as a fuel.

What are the hazard statements for TOTAL RENEWABLE DIESEL?

This substance has 1 hazard statements: H304: May be fatal if swallowed and enters airways.

What is the melting point of TOTAL RENEWABLE DIESEL?

The melting point is No data available and the boiling point is 180 320 C (1013 hPa).