NextSDS Logo
MO

MOISTURE GUARD Clear Spray

DANGER Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
MOISTURE GUARD Clear Spray
Product Form
Aerosol

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
7170-D091-300X-NCSG

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Corrosion inhibitors. Industrial use, Professional use. For professional use only.
Uses Advised Against
Acetone is listed as a reportable explosives precursor in Annex II of EU regulation 2019/1148

Overview

MOISTURE GUARD Clear Spray commonly used corrosion inhibitors. industrial use, professional use. for professional use only..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Skin corrosion/irritation Category 2 H315
STOT SE Category 3 H336
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P410+P412: Protect from sunlight. Do not expose to temperatures exceeding 50 /122 F.
  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P211: Do not spray on an open flame or other ignition source.
  • P251: Do not pierce or burn, even after use.
  • P271: Use only outdoors or in a well-ventilated area.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection/hearing protection.
  • P302+P352: IF ON SKIN: Wash with plenty of water.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

ROCOL a division of ITW Ltd company logo - Safety Data Sheet supplier organization

ROCOL a division of ITW Ltd

manufacturer

๐Ÿ“

Rocol House Wakefield Rd, Swillington LS26 8BS Leeds - West Yorkshire United Kingdom

๐ŸŒ

GB

๐ŸŒ www.rocol.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ROCOL a division of ITW Ltd

๐Ÿ“ž

+44 (0)113 232 2600

๐ŸŒ

GB

National Poisons Information Service (Birmingham Centre) City Hospital

๐Ÿ“ž

0344 892 0111

๐ŸŒ

GB

๐Ÿ’ก

Only for healthcare professionals

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
HYDROCARBON AEROSOL PROPELLANT (<0.1% 1,3-BUTADIENE) substance with national workplace exposure limit(s) (GB)
EC: 270-704-2
68476-85-7 50-70% โš ๏ธ Hazardous
HEPTANE & ISOMERS
EC: 927-510-4
64742-49-0 15-30% โš ๏ธ Hazardous
ACETONE substance with national workplace exposure limit(s) (GB); substance with a Community workplace exposure limit
EC: 200-662-2
67-64-1 5-10% โš ๏ธ Hazardous

Additional Information

Full text of H- and EUH-statements: see section 16

Composition Notes

Product subject to CLP Article 1.1.3.7. The disclosure rules of the components is modified in this case.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell.

Symptoms:

May cause drowsiness or dizziness.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

๐Ÿšจ Immediate Medical Attention Required

Obtain medical attention if pain, blinking or redness persists (for eye contact). Obtain emergency medical attention (for ingestion). Call a POISON CENTER/doctor if you feel unwell (for inhalation).

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
brown.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Characteristic odour.
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
Critical Property
๐Ÿ’จ Boiling Point
< 0
Critical Property
๐Ÿ”ฅ Flash Point
< 100
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
= 0.6
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
Critical Property
๐Ÿ”ฅ Flammability
Non flammable.
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
> 200
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
insoluble in water.
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
563 g/l
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Wear protective gloves. Nitrile rubber gloves

๐Ÿ‘๏ธ Eye Protection

Chemical goggles or safety glasses

๐Ÿ˜ท Respiratory Protection

In case of inadequate ventilation wear respiratory protection. Wear a respirator conforming to EN140 with Type A filter or better

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 1950

๐Ÿ“ฆ Proper Shipping Name

AEROSOLS

โš ๏ธ Transport Hazard Class

2.1

๐Ÿ“‹ Packing Group

Not applicable

๐Ÿš› ADR Transport Precautions

Special provisions for carriage - Packages (ADR) : V14; Special provisions for carriage - Loading, unloading and handling (ADR) : CV9, CV12; Special provisions for carriage - Operation (ADR) : S2

๐Ÿšข IMDG Maritime Transport Precautions

Stowage category (IMDG) : None; Stowage and handling (IMDG) : SW1, SW22; Segregation (IMDG) : SG69

โœˆ๏ธ IATA Air Transport Precautions

ERG code (IATA) : 10L

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for MOISTURE GUARD Clear Spray?

The signal word for this substance is "danger".

What is the physical form of MOISTURE GUARD Clear Spray?

MOISTURE GUARD Clear Spray is a liquid with brown. color. It has characteristic odour. odor.

What is the solubility of MOISTURE GUARD Clear Spray?

insoluble in water.

What is MOISTURE GUARD Clear Spray used for?

Corrosion inhibitors. Industrial use, Professional use. For professional use only.

What are the hazard statements for MOISTURE GUARD Clear Spray?

This substance has 5 hazard statements: H222: Extremely flammable aerosol. H229: Pressurised container: May burst if heated. H315: Causes skin irritation. H336: May cause drowsiness or dizziness. H412: Harmful to aquatic life with long lasting effects.

What is the melting point of MOISTURE GUARD Clear Spray?

The melting point is Not available and the boiling point is < 0.