Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
ARCAL Chrome commonly used industrial and professional uses. perform risk assessment prior to use. contact supplier for more information on uses. industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS04
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H280: Contains gas under pressure; may explode if heated.
Precautionary Statements
- P403: Store in a well-ventilated place.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
AIR LIQUIDE BV
national supplier
De Witbogt 1 5652 AG Eindhoven the Netherlands-Nederland
NL
+31 (0)40 250 35 03
L'AIR LIQUIDE BELGE S.A./N.V.
national supplier
Hermeslaan 11 1932 Zaventem Belgium-Belgique-Belgi
BE
+32 (0)2 540 86 60
L'AIR LIQUIDE LUXEMBOURG S.A.
national supplier
ZONE P.E.D .- B.P.20 L-4801 RODANGE Luxemburg
LU
+352 26 30 29 03
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid
+32 70 245 245
BE
24/7
Please dial: 070 245 245 for any urgent questions about intoxication (free of charge 24/7), if not accessible, dial: 02 264 96 30 (standard fee)
Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid
02 264 96 30
BE
if not accessible, dial: 02 264 96 30 (standard fee)
Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid
+352 8002 5500
LU
24/7 access
Languages: FR, NL, EN
Free telephone number with a 24/7 access. Experts answer all urgency questions on dangerous products in French, Dutch and English
Nationaal Vergiftigingen Informatie Centrum
+31 88 755 80 00
NL
24 hours a day, 7 days a week
Only for the purpose of informing medical personnel in cases of acute intoxications (24 hours a day, 7 days a week)
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Contains no other components or impurities which will influence the classification of the product.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Argon (diep gekoeld) EC: 231-147-0 | 7440-37-1 | Not specified | โ ๏ธ Hazardous |
| CARBON DIOXIDE AEROSOL PROPELLANT substance with national workplace exposure limit(s) (GB); substance with a Community workplace exposure limit EC: 204-696-9 | 124-38-9 | Not specified | โ ๏ธ Hazardous |
Additional Information
*1: Listed in Annex IV / V REACH, exempted from registration. *3: Registration not required: Substance manufactured or imported < 1t/y.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Allow affected person to breathe fresh air. Allow the victim to rest. Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.
Symptoms:
In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.
๐๏ธ Skin Contact
Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.
Symptoms:
Adverse effects not expected from this product.
๐๏ธ Eye Contact
Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists.
Symptoms:
Adverse effects not expected from this product.
๐ฝ๏ธ Ingestion/Swallowing
Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.
Symptoms:
Ingestion is not considered a potential route of exposure.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Provide adequate general and local exhaust ventilation. Systems under pressure should be regularily checked for leakages. Ensure exposure is below occupational exposure limits (where available). Oxygen detectors should be used when asphyxiating gases may be released. Consider the use of a work permit system e.g. for maintenance activities.
๐งค Hand Protection
Wear protective gloves. Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risks, performance level 1 or higher. Recommended types include wrist gloves from leather or synthetic material with equivalent performance, fabric gloves, fabric gloves with leather palms.
๐๏ธ Eye Protection
A risk assessment should be conducted and documented in each work area to assess the risks related to the use of the product and to select the PPE that matches the relevant risk. The following recommendations should be considered: PPE compliant to the recommended EN/ISO standards should be selected. : Wear safety glasses with side shields. Chemical goggles or safety glasses. Standard EN 166 - Personal eye-protection - specifications.
๐ท Respiratory Protection
Gas filters may be used if all surrounding conditions e.g. type and concentration of the contaminant(s) and duration of use are known. Wear appropriate mask. Use gas filters with full face mask, where exposure limits may be exceeded for a short-term period, e.g. connecting or disconnecting containers. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Consult respiratory device supplier's product information for the selection of the appropriate device. When indicated by a risk assessment, Respiratory Protective Equipment must be used. The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD. Gas filters do not protect against oxygen deficiency. Self contained breathing apparatus (SCBA) or positive pressure airline with mask are to be used in oxygen-deficient atmospheres. Standard EN 14387 - Gas filter(s), combined filter(s) and standard EN136, full face masks . Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems.
๐ฆบ Skin/Body Protection
Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.
๐ Environmental Exposure Controls
None necessary.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
1956
๐ฆ Proper Shipping Name
COMPRESSED GAS, N.O.S. (Argon, Carbon dioxide)
โ ๏ธ Transport Hazard Class
2
๐ ADR Transport Precautions
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
๐ข IMDG Maritime Transport Precautions
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
โ๏ธ IATA Air Transport Precautions
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for ARCAL Chrome?
The signal word for this substance is "warning".
What is the physical form of ARCAL Chrome?
ARCAL Chrome is a gas. with colourless. color. It has characteristic. odor.
What is ARCAL Chrome used for?
Industrial and professional uses. Perform risk assessment prior to use. Contact supplier for more information on uses. Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions.
What are the hazard statements for ARCAL Chrome?
This substance has 1 hazard statements: H280: Contains gas under pressure; may explode if heated.
What is the melting point of ARCAL Chrome?
The melting point is Not applicable for gas mixtures. and the boiling point is Not applicable for gas mixtures. It is technically not possible to determine the boiling point or range of this mixture. Component with lowest boiling point: Argon -186.