NextSDS Logo
te

tert-Butanol for analysis EMSURE ACS

DANGER solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
tert-Butanol for analysis EMSURE ACS
Product Code
109629
Chemical Name
tert-butanol (2methyl-2-propanol)
Synonyms
t-Butyl Alcohol

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Reagent for analysis

Overview

tert-Butanol for analysis EMSURE ACS (CAS: 75-65-0 ) commonly used reagent for analysis.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Acute Tox. Category 4 H332
Eye Irrit. Category 2 H319
STOT SE Category 3 H336
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Highly flammable liquid and vapour.
  • H319: Causes serious eye irritation.
  • H332: Harmful if inhaled.
  • H335: May cause respiratory irritation.
  • H336: May cause drowsiness or dizziness.

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P240: Ground/bond container and receiving equipment.
  • P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P403 + P233: Store in a well-ventilated place. Keep container tightly closed.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA company logo - Safety Data Sheet supplier organization

Merck KGaA

manufacturer

๐Ÿ“

64271 Darmstadt * Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 6151 72-0

๐ŸŒ www.merckgroup.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

tert-Butanol for analysis EMSURE ACS

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
tert-butanol (2methyl-2-propanol)
EC: 200-889-7
75-65-0 100% โš ๏ธ Hazardous

Composition Notes

For the full text of the H-Statements mentioned in this Section, see Section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

fresh air. Call in physician. If breathing stops: immediately apply artificial respiration, if necessary also oxygen.

Symptoms:

Cough, respiratory paralysis, Shortness of breath

๐Ÿ–๏ธ Skin Contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Symptoms:

irritant effects

๐Ÿ‘๏ธ Eye Contact

rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.

Symptoms:

irritant effects

๐Ÿฝ๏ธ Ingestion/Swallowing

immediately make victim drink water (two glasses at most). Subsequently administer: activated charcoal (20 - 40 g in 10% slurry). Consult a physician.

Symptoms:

Nausea, Vomiting, cardiovascular disorders, CNS disorders

๐Ÿšจ Immediate Medical Attention Required

Call in physician (for inhalation), Call in ophthalmologist (for eye contact), Consult a physician (for swallowing).

Medical Treatment

Laxative: Sodium sulfate (1 tablespoon/1/4 l water).

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
solid
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
solid
๐Ÿ‘ƒ Odor
camphor-like
๐Ÿ“Š Odor Threshold
71 ppm
๐Ÿงช Ph
neutral
๐ŸงŠ Melting Point
25,7 C
Critical Property
๐Ÿ’จ Boiling Point
83 C at 1.013 hPa
Critical Property
๐Ÿ”ฅ Flash Point
15 C at 1.013 hPa
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No information available.
๐Ÿ’จ Vapor Pressure
54,3 hPa at 25 C
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
No information available.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,78 g/cm3 at 20 C
Critical Property
๐Ÿ”ฅ Flammability
No information available.
๐Ÿ“Š Upper Explosive Limit
8,0 %(V)
๐Ÿ“Š Lower Explosive Limit
2,3 %(V)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
490 C
๐Ÿ“Š Decomposition Temperature
No information available.
๐Ÿ’ง Solubility
soluble
๐Ÿ“Š Partition Coefficient
log Pow: 0,30 OECD Test Guideline 107
๐Ÿ“Š Solubility In Water
1.000 g/l at 25 C
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
3,3 mPa.s at 30 C
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

๐Ÿงค Hand Protection

full contact: Glove material: Nitrile rubber Glove thickness: 0,40 mm Break through time: 480 min splash contact: Glove material: polychloroprene Glove thickness: 0,65 mm Break through time: 240 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 730 Camatril Velours (full contact), KCL 720 Camapren (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g., KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

๐Ÿ‘๏ธ Eye Protection

Safety glasses

๐Ÿ˜ท Respiratory Protection

required when vapours/aerosols are generated. Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

๐Ÿฆบ Skin/Body Protection

Flame retardant antistatic protective clothing.

๐ŸŒ Environmental Exposure Controls

Do not let product enter drains. Risk of explosion.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 1120

๐Ÿ“ฆ Proper Shipping Name

BUTANOLS

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

II

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is tert-Butanol for analysis EMSURE ACS known by?

tert-Butanol for analysis EMSURE ACS is also known as: t-Butyl Alcohol

What is the hazard signal word for tert-Butanol for analysis EMSURE ACS?

The signal word for this substance is "danger".

What is the physical form of tert-Butanol for analysis EMSURE ACS?

tert-Butanol for analysis EMSURE ACS is a solid with colourless color. It has camphor-like odor.

What is the solubility of tert-Butanol for analysis EMSURE ACS?

soluble

What is tert-Butanol for analysis EMSURE ACS used for?

Reagent for analysis

What are the hazard statements for tert-Butanol for analysis EMSURE ACS?

This substance has 5 hazard statements: H225: Highly flammable liquid and vapour. H319: Causes serious eye irritation. H332: Harmful if inhaled. H335: May cause respiratory irritation. H336: May cause drowsiness or dizziness.

What is the melting point of tert-Butanol for analysis EMSURE ACS?

The melting point is 25,7 C and the boiling point is 83 C at 1.013 hPa.