NextSDS Logo
El

Elecsys sFit-1

WARNING liquid, Beads SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Elecsys sFit-1
Product Code
07027818190

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
For professional users only.

Overview

Elecsys sFit-1 commonly used for professional users only..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.

Precautionary Statements

  • P261: Avoid breathing mist or vapours
  • P272: Contaminated work clothing should not be allowed out of the workplace.
  • P280: Wear protective gloves.
  • P333 + P313: If skin irritation or rash occurs: Get medical advice/ attention.
  • P362 + P364: Take off contaminated clothing and wash it before reuse.
  • P501: Dispose of contents/ container to an approved waste disposal plant.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Roche Diagnostics Limited

manufacturer

๐Ÿ“

Charles Avenue Burgess Hill RH15 9RY West Sussex United Kingdom

๐ŸŒ

GB

๐Ÿ“ž

+44 1444 256000

๐Ÿ“ 

+44 1444 256239

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Roche Diagnostics Ltd.

๐Ÿ“ž

+44 1444 256500

๐ŸŒ

GB

Roche Diagnostics Ltd.

๐Ÿ“ž

+44 7802 260498

๐ŸŒ

GB

NPIS

๐Ÿ“ž

+44 844 892 0111

๐ŸŒ

GB

๐Ÿ•’

24Hr

๐Ÿ’ก

Toxicology help-line

NHS Direct

๐Ÿ“ž

+44 845 4647

๐ŸŒ

GB

๐Ÿ•’

24Hr

๐Ÿ’ก

Health Advice help-line

NHS 24

๐Ÿ“ž

+44 8454 242424

๐ŸŒ

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2-methyl-2H-isothiazol-3-one hy- drochloride
EC: 247-499-3
26172-54-3 0.0025-0.025% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

๐Ÿ–๏ธ Skin Contact

If on skin, rinse well with water.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eye(s) with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

๐Ÿฝ๏ธ Ingestion/Swallowing

Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Rinse mouth with water.

Medical Treatment

The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid, Beads
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
clear, colourless, red brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
odourless
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
7,1 - 7,4
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
does not flash
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
No data available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,01 g/cm3 (20 )
Critical Property
๐Ÿ”ฅ Flammability
The product is not flammable., Does not sustain combustion.
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
Water solubility: completely miscible; Solubility in other solvents: No data available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
completely miscible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
No data available
๐Ÿ“Š Kinematic Viscosity
No data available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No data available

๐Ÿงค Hand Protection

In case of contact through splashing: Material: Nitrile rubber, Break through time: > 30 min, Glove thickness: > 0,11 mm. In case of full contact: Material: butyl-rubber, Break through time: > 480 min, Glove thickness: > 0,4 mm. Remarks: The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The suitability for a specific workplace should be discussed with the producers of the protective gloves.

๐Ÿ‘๏ธ Eye Protection

Eye wash bottle with pure water Tightly fitting safety goggles. Use eye protection according to EN 166.

๐Ÿฆบ Skin/Body Protection

Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Elecsys sFit-1?

The signal word for this substance is "warning".

What is the physical form of Elecsys sFit-1?

Elecsys sFit-1 is a liquid, beads with clear, colourless, red brown color. It has odourless odor.

What is the solubility of Elecsys sFit-1?

Water solubility: completely miscible; Solubility in other solvents: No data available

What is Elecsys sFit-1 used for?

For professional users only.

What are the hazard statements for Elecsys sFit-1?

This substance has 1 hazard statements: H317: May cause an allergic skin reaction.

What is the melting point of Elecsys sFit-1?

The melting point is No data available and the boiling point is No data available.