NextSDS Logo
El

Elecsys sFit-1

WARNING liquid, Beads SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Elecsys sFit-1
Product Code
07027818190

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
For professional users only.

Overview

Elecsys sFit-1 commonly used for professional users only..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.

Precautionary Statements

  • P261: Avoid breathing mist or vapours
  • P272: Contaminated work clothing should not be allowed out of the workplace.
  • P280: Wear protective gloves.
  • P333 + P313: If skin irritation or rash occurs: Get medical advice/ attention.
  • P362 + P364: Take off contaminated clothing and wash it before reuse.
  • P501: Dispose of contents/ container to an approved waste disposal plant.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Roche Diagnostics Limited

manufacturer

Charles Avenue Burgess Hill RH15 9RY West Sussex United Kingdom

GB

+44 1444 256000

+44 1444 256239

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Roche Diagnostics Ltd.

+44 1444 256500

GB

Roche Diagnostics Ltd.

+44 7802 260498

GB

NPIS

+44 844 892 0111

GB

24Hr

Toxicology help-line

NHS Direct

+44 845 4647

GB

24Hr

Health Advice help-line

NHS 24

+44 8454 242424

GB

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2-methyl-2H-isothiazol-3-one hy- drochloride
EC: 247-499-3
26172-54-3 0.0025-0.025% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin Contact

If on skin, rinse well with water.

Eye Contact

Immediately flush eye(s) with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion/Swallowing

Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Rinse mouth with water.

Medical Treatment

The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Flammability
The product is not flammable., Does not sustain combustion.
Explosive Limits
Not available
Colour
clear, colourless, red brown
Odor Threshold
No data available
Properties Status
Not available
Boiling Point
No data available
Critical Property
Solidification Point
Not available
Dynamic Viscosity
No data available
Physical State Data
liquid
Melting Point
No data available
Critical Property
Relative Evaporation Rate
Not available
Lower Explosive Limit
No data available
Decomposition Temperature
No data available
Solubility In Water
completely miscible
Ph
7,1 - 7,4
Voc Content
Not available
Auto Ignition Temperature
No data available
Softening Point
Not available
Flash Point
does not flash
Critical Property
Solubility
Water solubility: completely miscible; Solubility in other solvents: No data available
State Under Standard Conditions
Not available
Crystallisation Point
Not available
Physical State
liquid, Beads
Critical Property
Form
Not available
Evaporation Rate
No data available
Solubility In Fat
Not available
Relative Density
No data available
Kinematic Viscosity
No data available
Molecular Weight
Not available
Freezing Point
Not available
Colour Intensity
Not available
Metal Corrosion
Not available
Odor
odourless
Appearance
Not available
Density
1,01 g/cm3 (20 )
Critical Property
Partition Coefficient
No data available
Vapor Density
Not available
Vapor Pressure
No data available
Bulk Density
Not available
Upper Explosive Limit
No data available
Cloud Point
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

No data available

Hand Protection

In case of contact through splashing: Material: Nitrile rubber, Break through time: > 30 min, Glove thickness: > 0,11 mm. In case of full contact: Material: butyl-rubber, Break through time: > 480 min, Glove thickness: > 0,4 mm. Remarks: The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. The suitability for a specific workplace should be discussed with the producers of the protective gloves.

Eye Protection

Eye wash bottle with pure water Tightly fitting safety goggles. Use eye protection according to EN 166.

Skin/Body Protection

Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Elecsys sFit-1?

The signal word for this substance is "warning".

What is the physical form of Elecsys sFit-1?

Elecsys sFit-1 is a liquid, beads with clear, colourless, red brown color. It has odourless odor.

What is the solubility of Elecsys sFit-1?

Water solubility: completely miscible; Solubility in other solvents: No data available

What is Elecsys sFit-1 used for?

For professional users only.

What are the hazard statements for Elecsys sFit-1?

This substance has 1 hazard statements: H317: May cause an allergic skin reaction.

What is the melting point of Elecsys sFit-1?

The melting point is No data available and the boiling point is No data available.