DANGER Fluid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
GRF UNI Durapipe PVC -100 BO 250ML -U Solvent Cement *24 ENDE

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Adhesive

Overview

GRF UNI Durapipe PVC -100 BO 250ML -U Solvent Cement *24 ENDE is a fluid substance commonly used adhesive.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Carc. Category 2 H351
Eye Dam. Category 1 H318
Skin Irrit. Category 2 H315
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Highly flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.
  • H335: May cause respiratory irritation.
  • H351: Suspected of causing cancer.

Precautionary Statements

  • P101: If medical advice is needed, have product container or label at hand.
  • P102: Keep out of reach of children.
  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P261: Avoid breathing vapours.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P403 + P233: Store in a well-ventilated place. Keep container tightly closed.
  • P501: Dispose of contents/container in accordance with national regulations.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

Dr.A.F.Philipsstraat 9 NL-4462 EW Goes PO Box 160 NL-4460 AD Goes

NL

+31 88 3235700

+31 88 3235800

PSRA

undefined

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

National Poisons Information Centre

+353 (1) 809 2166

IE

8.00 a.m. to 10.00 p.m. 7 days a week

Healthcare Professionals

+353 (1) 809 2566

IE

24 hour service

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Adhesive

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
tetrahydrofuran
EC: 203-726-8
109-99-9 50-100% Hazardous
CYCLO-HEXANONE
EC: 203-631-1
108-94-1 10-25% Hazardous
METHYLETHYLCETONE
EC: 201-159-0
78-93-3 2.5-10% Hazardous
butylated hydroxy toluene
EC: 204-881-4
128-37-0 0.025-0.25% Hazardous

Additional Information

For the wording of the listed hazard phrases refer to section 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Call a doctor immediately. In case of unconsciousness place patient stably in side position for transportation.

Skin Contact

Immediately wash with water and soap and rinse thoroughly.

Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion/Swallowing

Rinse out mouth and then drink plenty of water.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Form
Fluid
Freezing Point
Undetermined.
Physical State Data
liquid
State Under Standard Conditions
Not available
Bulk Density
Not available
Solubility In Fat
Not available
Voc Content
78.77 %
Decomposition Temperature
Not determined.
Odor Threshold
Not determined.
Upper Explosive Limit
12 Vol %
Vapor Pressure
at 20 C: 200 hPa; at 50 C: 550 hPa
Auto Ignition Temperature
230 C
Colour Intensity
Not available
Molecular Weight
Not available
Evaporation Rate
Not determined.
Boiling Point
65.5 C
Critical Property
Solubility
Not miscible or difficult to mix.
Appearance
Fluid
Relative Evaporation Rate
Not available
Colour
According to product specification
Dynamic Viscosity
1450 mPas
Flammability
Highly flammable.
Melting Point
Undetermined.
Critical Property
Physical State
Fluid
Critical Property
Relative Density
Not determined.
Density
1.023 g/cm
Critical Property
Solidification Point
Not available
Explosive Limits
Not available
Properties Status
Not available
Flash Point
-21 C
Critical Property
Solubility In Water
Not miscible or difficult to mix.
Metal Corrosion
Void
Softening Point
Not available
Crystallisation Point
Not available
Odor
Characteristic
Ph
Not determined.
Kinematic Viscosity
Not determined.
Lower Explosive Limit
1.3 Vol %
Cloud Point
Not available
Partition Coefficient
Not determined.
Vapor Density
Not determined.
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Solvent resistant gloves Protective gloves The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation Material of gloves Recommended thickness of the material: > 0,12 mm Butyl rubber, BR Nitrile rubber, NBR Recommended thickness of the material: > 0,7 mm Penetration time of glove material For the mixture of chemicals mentioned below the penetration time has to be at least 10 minutes (Permeation according to EN 374 Part 3: Level 1). For the mixture of chemicals mentioned below the penetration time has to be at least 120 minutes (Permeation according to EN 374 Part 3: Level 4).

Eye Protection

Tightly sealed goggles Goggles recommended during refilling

Respiratory Protection

Suitable respiratory protective device recommended. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Use suitable respiratory protective device in case of insufficient ventilation. Recommended filter device for short term use: Filter A

Skin/Body Protection

Use protective suit. Solvent resistant protective clothing

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1133

Proper Shipping Name

ADHESIVES

Packing Group

III

ADR Transport Precautions

Warning: Flammable liquids.

IMDG Maritime Transport Precautions

Warning: Flammable liquids.

IATA Air Transport Precautions

Warning: Flammable liquids.

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for GRF UNI Durapipe PVC -100 BO 250ML -U Solvent Cement *24 ENDE?

The signal word for this substance is "danger".

What is the physical form of GRF UNI Durapipe PVC -100 BO 250ML -U Solvent Cement *24 ENDE?

GRF UNI Durapipe PVC -100 BO 250ML -U Solvent Cement *24 ENDE is a fluid appearing as fluid with according to product specification color. It has characteristic odor.

What is the solubility of GRF UNI Durapipe PVC -100 BO 250ML -U Solvent Cement *24 ENDE?

Not miscible or difficult to mix.

What is GRF UNI Durapipe PVC -100 BO 250ML -U Solvent Cement *24 ENDE used for?

Adhesive

What are the hazard statements for GRF UNI Durapipe PVC -100 BO 250ML -U Solvent Cement *24 ENDE?

This substance has 5 hazard statements: H225: Highly flammable liquid and vapour. H315: Causes skin irritation. H318: Causes serious eye damage. H335: May cause respiratory irritation. H351: Suspected of causing cancer.

What is the melting point of GRF UNI Durapipe PVC -100 BO 250ML -U Solvent Cement *24 ENDE?

The melting point is Undetermined. and the boiling point is 65.5 C.