Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Formic acid 98-100% for analysis EMSURE
- Product Code
- 1.00264, 100264
Regulatory Identifiers
- CAS Number
- 64-18-6 Check regulations →
Identified Uses
Reagent for analysis, Chemical production
Uses advised against
The product is being supplied under the TSCA R&D Exemption (40 CFR Section 720.36). It is the recipients responsibility to comply with the requirements of the R&D exemption. The product may not be used for a non-exempt commercial purpose under TSCA unless appropriate consent is granted in writing by MilliporeSigma.
Manufacturers & Suppliers
Sigma-Aldrich Inc.
global supplier
3050 SPRUCE ST ST. LOUIS MO 63103 UNITED STATES
+1 314 771-5765
Emergency Contacts
CHEMTREC
800-424-9300
24 Hours/day; 7 Days/week
CHEMTREC
+1-703-527-3887
24 Hours/day; 7 Days/week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS06
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | 100% | Yes |
For the full text of the H-Statements mentioned in this Section, see Section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Immediately call in physician. If breathing stops: immediately apply artificial respiration, if necessary also oxygen.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Call a physician immediately.
After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.
After swallowing: make victim drink water (two glasses at most). Call a physician immediately.
Symptoms: Risk of perforation, pulmonary failure possible after aspiration of vomit.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Sulfuric acid 98% for analysis EMSURE
CAS: 7664-93-9
Sulfuric acid 95-97% for analysis EMSURE® ISO
CAS: 7664-93-9
Formic acid 99-100% a.r.
CAS: 64-18-6
Hydrofluoric acid 48% for analysis EMSURE® ACS,ISO,Reag. Ph Eur
---
Sulfuric acid 25% for analysis EMSURE
---
Hydrochloric acid 25% for analysis EMSURE
---
Acetic acid (glacial) 100% anhydrous for analysis EMSURE
CAS: 64-19-7
n-Butyl acetate for analysis EMSURE
CAS: 123-86-4
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact: Material: Chloroprene, Minimum layer thickness: 0.65 mm, Break through time: 480 min, Material tested: KCL 720 Camapren. Splash contact: Material: Latex gloves, Minimum layer thickness: 0.6 mm, Break through time: 60 min, Material tested: Lapren (KCL 706 / Aldrich Z677558, Size M). This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
Recommended Filter type: Filter E-(P3). The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented. required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Flame retardant antistatic protective clothing.
Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1779
- Shipping Name
- Formic acid
- Transport Class
- 8 (3)
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Formic acid 98-100% for analysis EMSURE?
The signal word is danger.
What is the physical form of Formic acid 98-100% for analysis EMSURE?
Formic acid 98-100% for analysis EMSURE is a liquid appearing as liquid, colorless with colorless color. It has stinging odor.
What is Formic acid 98-100% for analysis EMSURE used for?
Reagent for analysis, Chemical production
What are the hazard statements for Formic acid 98-100% for analysis EMSURE?
This substance has 4 hazard statements:
- H226: Flammable liquid and vapor.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H331: Toxic if inhaled.
What is the melting point of Formic acid 98-100% for analysis EMSURE?
The melting point is 8.5 C (47.3 F) and the boiling point is 100.80 C 213.44 F at 1,013 hPa.