NextSDS Logo
Bi

Bio-Cut Spray

DANGER Aerosol. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Bio-Cut Spray
Product Code
117500

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Overview

Bio-Cut Spray .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1
Press. Gas (Comp.)

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS04 GHS Hazard Pictogram: Compressed gas hazard - Pressurized gases that may explode if heated

GHS04

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Extremely flammable aerosol.
  • H280: Contains gas under pressure; may explode if heated.

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P211: Do not spray on an open flame or other ignition source.
  • P251: Do not pierce or burn, even after use.
  • P410 + P412: Protect from sunlight. Do not expose to temperatures exceeding 50 C/122 F.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

WEICON GmbH & Co. KG company logo - Safety Data Sheet supplier organization

WEICON GmbH & Co. KG

manufacturer

๐Ÿ“

Knigsberger Str. 255 48157 Mnster Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 251 93220

๐Ÿ“ 

+49(0)251 / 9322 - 244

๐ŸŒ www.weicon.de
WEICON Canada Inc. company logo - Safety Data Sheet supplier organization

WEICON Canada Inc.

national supplier

๐Ÿ“

20 Steckle Place, Unit 20 Kitchener, Ontario N2E 2C3, CA

๐ŸŒ

CA

๐Ÿ“ž

+1-519-896-5252

๐Ÿ“ 

+1-519-896-5254

๐ŸŒ www.weicon.ca

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+1 866 928 0789

๐ŸŒ

CA

๐Ÿ•’

24h

๐Ÿ’ก

Toll free

TRANSPORT EMERGENCY CONTACT

๐Ÿ“ž

+1 866 928 0789

๐ŸŒ

CA

๐Ÿ•’

24h

๐Ÿ’ก

Toll free

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Additional Information

Occupational exposure limits, if available, are listed in Section 8.

Composition Notes

There are no ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms:

No known significant effects or critical hazards. Adverse symptoms may include the following: respiratory tract irritation, coughing

๐Ÿ–๏ธ Skin Contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms:

No known significant effects or critical hazards. No specific data.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.

Symptoms:

No known significant effects or critical hazards. Adverse symptoms may include the following: irritation, redness

๐Ÿฝ๏ธ Ingestion/Swallowing

Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms:

No known significant effects or critical hazards. No specific data.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention if irritation occurs, if adverse health effects persist or are severe, if symptoms occur, or if unconscious. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled. No specific treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Aerosol.
Critical Property
๐Ÿ“Š Physical State Data
aerosol
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colorless.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Characteristic.
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not available.
๐ŸงŠ Melting Point
Not available.
Critical Property
๐Ÿ’จ Boiling Point
Not available.
Critical Property
๐Ÿ”ฅ Flash Point
Closed cup: Not applicable.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
350 kPa (2625.2 mm Hg) [room temperature]
๐Ÿ“Š Vapor Density
Not available.
๐Ÿ“Š Relative Density
Not available.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0.72 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Not available.
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
0.6%
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
>250C (>482F)
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Not available.
๐Ÿ“Š Partition Coefficient
Not available.
๐Ÿ“Š Solubility In Water
Not available.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use only with adequate ventilation. If user operations generate dust, fumes, gas, vapor or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

๐Ÿงค Hand Protection

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. Recommended : 1 - 4 hours (breakthrough time): nitrile rubber 4 - 8 hours (breakthrough time): Viton/butyl rubber

๐Ÿ‘๏ธ Eye Protection

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

๐Ÿ˜ท Respiratory Protection

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended : organic vapor (Type AX) and particulate filter

๐Ÿฆบ Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1950

๐Ÿ“ฆ Proper Shipping Name

AEROSOLS

โš ๏ธ Transport Hazard Class

2.1

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Bio-Cut Spray?

The signal word for this substance is "danger".

What is the physical form of Bio-Cut Spray?

Bio-Cut Spray is a aerosol. with colorless. color. It has characteristic. odor.

What is the solubility of Bio-Cut Spray?

Not available.

What are the hazard statements for Bio-Cut Spray?

This substance has 2 hazard statements: H222: Extremely flammable aerosol. H280: Contains gas under pressure; may explode if heated.

What is the melting point of Bio-Cut Spray?

The melting point is Not available. and the boiling point is Not available..