NextSDS Logo
Safety Data Sheet EN

Shell Gadus S3 Wirerope T

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Shell Gadus S3 Wirerope T
Product Code
001D8500

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Automotive and industrial grease.

Uses advised against

This product must not be used in applications other than those listed in Section 1 without first seeking the advice of the supplier.

Manufacturers & Suppliers

S

Shell Deutschland GmbH

manufacturer

Suhrenkamp 71-77 D-22335 Hamburg

(+49) 40 6324-6255

Emergency Contacts

Giftnotruf Berlin

(+49) 30 3068 6700

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

A lubricating grease containing highly-refined mineral oils and additives. The highly refined mineral oil contains <3% (w/w) DMSOextract, according to IP346.

Chemical Name CAS Number Concentration Hazardous
Naphthenic acids, bismuth salts EC: 288-470-5 85736-59-0 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No treatment necessary under normal conditions of use. If symptoms persist, obtain medical advice.

Skin contact

Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention. When using high pressure equipment, injection of product under the skin can occur. If high pressure injuries occur, the casualty should be sent immediately to a hospital. Do not wait for symptoms to develop. Obtain medical attention even in the absence of apparent wounds.

Symptoms: Oil acne/folliculitis signs and symptoms may include formation of black pustules and spots on the skin of exposed areas. Local necrosis is evidenced by delayed onset of pain and tissue damage a few hours following injection.

Eye contact

Flush eye with copious quantities of water. Remove contact lenses, if present and easy to do. Continue rinsing. If persistent irritation occurs, obtain medical attention.

Ingestion

In general no treatment is necessary unless large quantities are swallowed, however, get medical advice.

Symptoms: Ingestion may result in nausea, vomiting and/or diarrhoea.

Immediate Medical Attention

If high pressure injuries occur, the casualty should be sent immediately to a hospital. Do not wait for symptoms to develop. Obtain medical attention even in the absence of apparent wounds. High pressure injection injuries require prompt surgical intervention and possibly steroid therapy, to minimise tissue damage and loss of function.

Medical Treatment

Notes to doctor/physician: Treat symptomatically. High pressure injection injuries require prompt surgical intervention and possibly steroid therapy, to minimise tissue damage and loss of function. Because entry wounds are small and do not reflect the seriousness of the underlying damage, surgical exploration to determine the extent of involvement may be necessary. Prompt surgical decompression, debridement and evacuation of foreign material should be performed under general anaesthetics, and wide exploration is essential.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Select controls based on a risk assessment of local circumstances. Appropriate measures include: Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated. General Information: Define procedures for safe handling and maintenance of controls. Educate and train workers in the hazards and control measures relevant to normal activities associated with this product. Ensure appropriate selection, testing and maintenance of equipment used to control exposure, e.g. personal protective equipment, local exhaust ventilation. Drain down system prior to equipment break-in or maintenance. Retain drain downs in sealed storage pending disposal or subsequent recycle.

Hands

Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. PVC, neoprene or nitrile rubber gloves Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model.

Eyes

If material is handled such that it could be splashed into eyes, protective eyewear is recommended. Approved to EU Standard EN166.

Respiratory

No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [Type A/Type P boiling point > 65C (149F)] meeting EN14387 and EN143.

Skin/Body

Skin protection is not ordinarily required beyond standard work clothes. It is good practice to wear chemical resistant gloves.

Environmental

Take appropriate measures to fulfill the requirements of relevant environmental protection legislation. Avoid contamination of the environment by following advice given in Section 6. If necessary, prevent undissolved material from being discharged to waste water. Waste water should be treated in a municipal or industrial waste water treatment plant before discharge to surface water. Local guidelines on emission limits for volatile substances must be observed for the discharge of exhaust air containing vapour.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Semi-solid at ambient temperature.
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Semi-solid at ambient temperature.
Colour
black
Colour Intensity
---
Form
---
Odor
Slight hydrocarbon
Odor Threshold
Data not available
Ph
Not applicable
Melting Point
Not applicable
Boiling Point
Data not available
Flash Point
Not applicable
Freezing Point
Not applicable
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Data not available
Vapor Pressure
< 0,5 Pa (20 C)
Vapor Density
---
Relative Density
1,00 (15 C)
Bulk Density
---
Density
<= 1.000 kg/m3 (15,0 C)
Flammability
Data not available
Upper Explosive Limit
Typical 10 %(V)
Lower Explosive Limit
Typical 1 %(V)
Explosive Limits
---
Auto Ignition Temperature
> 320 C
Decomposition Temperature
Data not available
Solubility
---
Partition Coefficient
log Pow: > 6
Solubility In Water
negligible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Data not available
Kinematic Viscosity
Not applicable
Properties Status
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Shell Gadus S3 Wirerope T?

The signal word is no signal word.

What is the physical form of Shell Gadus S3 Wirerope T?

Shell Gadus S3 Wirerope T is a semi-solid at ambient temperature. appearing as semi-solid at ambient temperature. with black color. It has slight hydrocarbon odor.

What is Shell Gadus S3 Wirerope T used for?

Automotive and industrial grease.

What is the melting point of Shell Gadus S3 Wirerope T?

The melting point is Not applicable and the boiling point is Data not available.