Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Unique Formula Identifier - for poison centres and emergency response
Uses Information
Overview
SIP100PE UFI is a not available. substance commonly used cleaning products wipes industrial/professional use.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H225: Highly flammable liquid and vapour.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
Precautionary Statements
- Wear eye or face protection. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Avoid breathing vapour.
- IF INHALED: Call a POISON CENTER or doctor if you feel unwell. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice or attention.
- Store in a well-ventilated place. Keep container tightly closed.
- Dispose of contents and container in accordance with all local, regional, national and international regulations.
Manufacturers & Suppliers
Authorized suppliers, manufacturers, and distribution network information
Chemtronics
manufacturer
8125 Cobb Center Drive Kennesaw, GA 30152
US
770-424-4888
ITW Contamination Control BV
importer
Saffierlaan 5 VZ-2132 Hoofddorp The Netherlands
NL
+31 88 1307 400
+31 88 1307 499
Importer/Only Representative
undefined
Bay 150 Shannon Industrial Estate Shannon County Clare Ireland V14 DF82
IE
+353 61 771 500
24/7 Emergency Response
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
United Kingdom (England or Wales) National advisory body/Poison Centre
0845 46 47
GB
EMERGENCY HEALTH INFORMATION
Scotland National advisory body/Poison Centre
08454 24 24 24
GB
EMERGENCY HEALTH INFORMATION (UK only)
Chemtronics Product Information
800-TECH-401 (800-832-4401)
US
8:00 AM to 5:00 PM
EMERGENCY HEALTH INFORMATION; EMERGENCY SPILL INFORMATION; Transport information
Chemtronics Customer Service
800-645-5244
US
8:00 AM to 5:00 PM
EMERGENCY HEALTH INFORMATION; EMERGENCY SPILL INFORMATION; Transport information
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| propan-2-ol EC: 200-661-7 | 67-63-0 | 50-75% | Hazardous |
Composition Notes
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
Inhalation Exposure
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms:
Adverse symptoms may include the following: nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness
Skin Contact
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms:
Adverse symptoms may include the following: irritation, redness, dryness, cracking
Eye Contact
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
Symptoms:
Adverse symptoms may include the following: pain or irritation, watering, redness
Ingestion/Swallowing
Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms:
Adverse symptoms may include the following: Ingestion Seek medical attention.
Immediate Medical Attention Required
Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
Treat symptomatically. No specific treatment.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment
Occupational exposure limits, engineering controls, and required safety equipment
Engineering Controls
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
Hand Protection
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.
Eye Protection
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.
Respiratory Protection
Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.
Skin/Body Protection
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Environmental Exposure Controls
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
UN Number
UN3175
Proper Shipping Name
Solids containing flammable liquid, n.o.s.(CONTAINS Propan-2-ol)
Transport Hazard Class
4.1
Packing Group
II
ADR Transport Precautions
Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
IMDG Maritime Transport Precautions
Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
IATA Air Transport Precautions
Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for SIP100PE UFI?
The signal word for this substance is "danger".
What is the physical form of SIP100PE UFI?
SIP100PE UFI is a liquid. appearing as not available. with not available. color. It has not available. odor.
What is the solubility of SIP100PE UFI?
Yes.
What is SIP100PE UFI used for?
Cleaning products Wipes Industrial/Professional use
What are the hazard statements for SIP100PE UFI?
This substance has 3 hazard statements: H225: Highly flammable liquid and vapour. H319: Causes serious eye irritation. H336: May cause drowsiness or dizziness.
What is the melting point of SIP100PE UFI?
The melting point is Not available. and the boiling point is Not available..