Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CITRIKHEMO FAR 50% citric acid solution
- Chemical Name
- citric acid solution
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For heat disinfection and decalcification of the flow path of haemodialysis equipment after bicarbonate dialysis.
Manufacturers & Suppliers
FARMASOL TIBBİ ÜRÜNLER SANAYİ VE TİCARET A.Ş.
manufacturer
ORGANİZE SANAYİ BÖLGESİ 18.CADDE NO:7 MELİKGAZİ/KAYSERİ
+90 352 321 33 33
http://www.farmasol.com.tr
Emergency Contacts
MNT Emergency Advisory
+49 (0) 171 52 47 312
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Citric acid monohydrate EC: 201-069-1 | 77-92-9 | 50% | Yes |
Notes
The Classification Of This Chemical Substance Has Been Made By The Manufacturer.
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of breathing difficulties, remove the patient to fresh air. Get medical help if necessary.
Rinse affected areas of skin under running water for 10 min. Remove wet clothing, ensuring self-protection whilst doing so. Do not attempt neutralisation. In case of prolonged irritation symptoms: provide medical attention.
With the uninjured eye protected, rinse the injured eye under running water for 10 min with the lids wide open. Provide medical attention. After exposure to concentrated solution, transport to the ophthalmologist as soon as possible whilst continuing to rinse the eye.
Drink water immediately. Maximum 2 tumblers. Do not induce vomiting. Consult a doctor.
Immediate Medical Attention
In case of unconsciousness seek medical advice. Get medical help if necessary. Provide medical attention. Transport to the ophthalmologist as soon as possible. Consult a doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Citric acid solution is non-flammable. Tailor extinguishing measures to the surrounding fire.
Full water jet
Firefighter Protection
In case of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wash wet surfaces immediately with plenty of water. Avoid contact with eyes.
Small quantities are to be diluted with water then neutralised.
Large quantities are to be absorbed with sand, diatomaceous earth or expanded mica and their disposal effected in a sealed container.
Do not allow the substance to enter the sewer system. A risk to drinking water is possible only in the event that very large quantities infiltrate the subsoil and waters.
Cleaning method dependent on quantity of liquid released. Small quantities are to be diluted with water then neutralised.
Materials: sand, diatomaceous earth or expanded mica
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation of the work station. Avoid contact with skin and eyes. Avoid breathing dust/fume/gas/mist/vapours/spray. Wear personal protective equipment. Prevent aerosol formation or splashes. Keep away from ignition sources. Wash your hands before and during work. Remove clothing that is contaminated with the product and wash it before using again. It is forbidden to eat and drink anything in the application area. Do not smoke.
Store tightly sealed in a dry, cool and well-ventilated place. Protect from frost and excessive heat.
It is imperative that industrial hygiene standards are adhered to. Wash your hands before and during work. Remove clothing that is contaminated with the product and wash it before using again. It is forbidden to eat and drink anything in the application area. Do not smoke.
Avoid open flames, direct sunlight and other sources of ignition. Protect against electrostatic charges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure sufficient ventilation during production.
Required in the case of contact with 50% citric acid solution. Glove material: Natural rubber, natural latex (0.5 mm, ≥ 8 h); Polychloroprene (0.5 mm, ≥ 8 h). The protective gloves to be used must comply with the specifications of EC directive 89/686/EEC and the resulting standard EN 374, for example KCL 740 Dermatril.
Required in the case of contact with citric acid solution; use frame goggles with side protection. Provide an eye shower.
Use suitable respiratory masks in places where there is not sufficient ventilation during production.
Long-sleeved work clothing.
To avoid effects on people and the environment, work in accordance with the instructions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No data available.
Citric acid has an acidic reaction and can react violently with alkaline substances.
Dangerous reactions are possible with metals, bases, oxidants and reductants.
To avoid thermal decomposition, do not overheat.
No data available.
Avoid citric acid coming into contact with sodium hypochloride solution, as toxic chlorine gas will form in this case.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of the absorbed material by burning it in an appropriate facility with a license.
Dispose of product residues in observance of waste directive 2008/98/EC as well as national and regional regulations. Do not dispose of the product without checking the waste regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- No data available.
- Shipping Name
- No data available.
- Transport Class
- No data available.
- Packing Group
- No data available.
No data available.
No data available.
No data available.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
See Section 2 for information on classification and labeling.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CITRIKHEMO FAR 50% citric acid solution?
The signal word is danger.
What is the physical form of CITRIKHEMO FAR 50% citric acid solution?
CITRIKHEMO FAR 50% citric acid solution is a liquid appearing as colourless, liquid with no data available. color. It has odourless odor.
What is CITRIKHEMO FAR 50% citric acid solution used for?
For heat disinfection and decalcification of the flow path of haemodialysis equipment after bicarbonate dialysis.
What are the hazard statements for CITRIKHEMO FAR 50% citric acid solution?
This substance has 1 hazard statement:
- H319: Causes serious eye irritation.
What is the melting point of CITRIKHEMO FAR 50% citric acid solution?
The melting point is no data available. and the boiling point is no data available..