NextSDS Logo
Safety Data Sheet EN

Zinc Zn - 10 g/l in diluted HCl for ICP (C169.5CP)

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Zinc Zn - 10 g/l in diluted HCl for ICP (C169.5CP)
Product Code
C169.5CP
Chemical Name
Zinc Zn

Regulatory Identifiers

CAS Number
N/A
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted for registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Laboratory Reagent

Manufacturers & Suppliers

C

CPAchem Ltd.

manufacturer

2 Ivanka Terzieva Str. Bogomilovo 6065 Stara Zagora, BULGARIA

+359 42952901

Emergency Contacts

Austria

+43 1 31304 5620

Belgium

+32022649636

Bulgaria

+359 2 9154 409

Croatia

+38514686910

Cyprus

+3572240561

Czech Republic

+420267082257

Denmark

+45 72 54 40 00

Estonia

+3726943384

Finland

+358 5052 000

France

+33 3 85 21 92

Germany

+49-30-18412-0

Greece

+302106479250

Hungary

+34 (1) 476 1136

Ireland

+35318092566

Italy

+390649906140

Latvia

+371 67032600

Lithuania

+370 70662008

Luxembourg

+352 24785551

Netherland

+31 88 75 585 61

Norway

+47 21 07 70 00

Poland

+48 42 2530 400

Portugal

+351213303271

Romania

+40213183606

Slovakia

+421 2 5465 2307

Slovenia

+38614006039

Spain

+34 917689800

Sweden

+46104566750

United Kingdom (England or Wales)

0845 46 47

United Kingdom (Scotland)

08454 24 24 24 (UK only)

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Met. Corr. Cat. 1 H290
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H290 May be corrosive to metals.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P280 Wear eye protection / face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P332 + P313 If skin irritation occurs: Get medical advice/attention.
P406 Store in a corrosion resistant container / container with a resistant inner liner.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture: consisting of the following components.

Chemical Name CAS Number Concentration Hazardous
hydrochloric acid EC: 231-595-7 7647-01-0 5% Yes
zinc chloride EC: 231-592-0 7646-85-7 2.08% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Instructions

Use fire extinguishing methods suitable to surrounding conditions.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special precautions are necessary if used correctly.

Storage

None.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation - Material of gloves The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. - Penetration time of glove material The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Goggles recommended during refilling

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Properties Status
---
Voc Content
---
Density
1.66706 g/cm³
Odor Threshold
Not determined.
Dynamic Viscosity
Not determined.
Bulk Density
---
Crystallisation Point
---
Physical State
Fluid
Melting Point
Undetermined.
Colour Intensity
---
Freezing Point
Undetermined.
Kinematic Viscosity
Not determined.
Vapor Pressure
Not determined.
Metal Corrosion
May be corrosive to metals.
Solubility
---
Lower Explosive Limit
Not determined.
Solidification Point
---
State Under Standard Conditions
---
Vapor Density
Not determined.
Auto Ignition Temperature
Product is not selfigniting.
Physical State Data
liquid
Cloud Point
---
Relative Evaporation Rate
---
Boiling Point
100 – 110 °C
Evaporation Rate
Not determined.
Upper Explosive Limit
Not determined.
Appearance
Fluid
Odor
Characteristic
Molecular Weight
---
Explosive Limits
---
Ph
Not determined.
Decomposition Temperature
Not determined.
Relative Density
Not determined.
Form
Fluid
Softening Point
---
Flammability
Not applicable.
Solubility In Fat
---
Flash Point
Not applicable.
Partition Coefficient
Not determined.
Colour
According to product specification
Solubility In Water
Not miscible or difficult to mix.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Hazardous reactions

No dangerous reactions known.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3264
Shipping Name
CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S. (HYDROCHLORIC ACID, ZINC CHLORIDE)
Transport Class
8 Corrosive substances.
Packing Group
II
ADR

Warning: Corrosive substances.

IMDG

Warning: Corrosive substances.

IATA

Warning: Corrosive substances.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Zinc Zn - 10 g/l in diluted HCl for ICP (C169.5CP)?

The signal word is warning.

What is the physical form of Zinc Zn - 10 g/l in diluted HCl for ICP (C169.5CP)?

Zinc Zn - 10 g/l in diluted HCl for ICP (C169.5CP) is a fluid appearing as fluid with according to product specification color. It has characteristic odor.

What is Zinc Zn - 10 g/l in diluted HCl for ICP (C169.5CP) used for?

Laboratory Reagent

What are the hazard statements for Zinc Zn - 10 g/l in diluted HCl for ICP (C169.5CP)?

This substance has 4 hazard statements:

  • H290: May be corrosive to metals.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Zinc Zn - 10 g/l in diluted HCl for ICP (C169.5CP)?

The melting point is Undetermined. and the boiling point is 100 – 110 °C.

Compliance Scanner

Scan your compliance