Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ALCUPOL® P-3621S
- Synonyms
- Polymeric polyol.
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Manufacture of substances. Formulating, repackaging & distribution. Flexible foam industrial use. Rigid foam industrial use. Use in Coatings. Adhesives and sealants industrial use. Elastomers, TPU, polyamide, polyimide and synthetic fibres industrial use. Natural fibers industrial use. Foundry industrial use. Uses as material for composites.
Uses advised against
All other uses.
Manufacturers & Suppliers
REPSOL QUÍMICA, S.A.
Méndez Álvaro, 44 28045 - MADRID, Spain
+34 917538000 / +34 917538100 +34 977759100 / +34 926419500
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The components are not hazardous or are below required disclosure limits.
Material name: ALCUPOL® P-2321, ALCUPOL® P-2621, ALCUPOL® P-2921, ALCUPOL® P-3021, ALCUPOL® P-3041, A 958684Version #: 01 Revision date: - Issue date: 07-June-2021 PIS SPAIN <!-- PAGE 2 -->
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Call a physician if symptoms develop or persist.
Wash off with soap and water. Get medical attention if irritation develops and persists.
Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops and persists.
Rinse mouth. Get medical attention if symptoms occur.
Immediate Medical Attention
Call a physician if symptoms develop or persist. Get medical attention if irritation develops and persists. Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2).
Do not use water jet as an extinguisher, as this will spread the fire.
During fire, gases hazardous to health may be formed such as: Carbon oxides. Nitrogen Oxides.
Move containers from fire area if you can do so without risk. Use standard firefighting procedures and consider the hazards of other involved materials.
Firefighter Protection
Self-contained breathing apparatus and full protective clothing must be worn in case of fire.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
- For non-emergency personnel: Keep unnecessary personnel away. Follow standard emergency procedure. Wear appropriate personal protective equipment (See Section 8). - For emergency responders: Keep unnecessary personnel away. Ensure adequate ventilation. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Wear appropriate protective equipment and clothing during clean-up. Local authorities should be advised if significant spillages cannot be contained.
Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water.
Avoid discharge into drains, water courses or onto the ground.
Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water. Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination. Never return spills to original containers for re-use.
Materials: vermiculite, dry sand or earth, absorbent material (e.g. cloth, fleece)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure safe systems of work or equivalent arrangements are in place to manage risks. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other sources of ignition.
Store in tightly closed container.
Observe good industrial hygiene practices.
Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.
Wear suitable gloves tested to EN374. The requirements of EN 388 must be taken into account for applications involving mechanical hazards with the risk of abrasion or incision. The requirements outlined in EN 407 must be taken into consideration for tasks involving thermal hazards. The most suitable glove must be chosen in consultation with the gloves supplier, who can inform about the breakthrough time of the glove material.
Wear safety glasses with side shields (or goggles). Eye protection should meet standard EN 166.
In case of insufficient ventilation, wear suitable respiratory equipment. If engineering controls do not maintain airborne concentrations below recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure limits have not been established), an approved respirator must be worn. Use a positive-pressure air-supplied respirator if there is any potential for an uncontrolled release, exposure levels are not known, or any other circumstances where air-purifying respirators may not provide adequate protection. Appropriate respirator selection should be made by a qualified professional.
Wear suitable protective clothing.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels. Product should not reach the environment through wastewater or sewage.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
The product is stable and non-reactive under normal conditions of use, storage and transport.
No dangerous reaction known under conditions of normal use.
Contact with incompatible materials.
Strong oxidising agents.
No hazardous decomposition products are known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated as dangerous goods.
- Shipping Name
- Not regulated as dangerous goods.
- Transport Class
- Not assigned.
- Packing Group
- Not assigned.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is ALCUPOL® P-3621S known by?
ALCUPOL® P-3621S is also known as: Polymeric polyol.
What is the hazard signal word for ALCUPOL® P-3621S?
The signal word is no signal word.
What is the physical form of ALCUPOL® P-3621S?
ALCUPOL® P-3621S is a liquid. with no data available (*) color. It has no data available (*) odor.
What is the solubility of ALCUPOL® P-3621S?
No data available (*)
What is ALCUPOL® P-3621S used for?
Manufacture of substances. Formulating, repackaging & distribution. Flexible foam industrial use. Rigid foam industrial use. Use in Coatings. Adhesives and sealants industrial use. Elastomers, TPU, polyamide, polyimide and synthetic fibres industrial use. Natural fibers industrial use. Foundry industrial use. Uses as material for composites.
What is the melting point of ALCUPOL® P-3621S?
The melting point is No data available (*) and the boiling point is No data available (*).