Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 1-Methoxy-2-propanol ≥99 %, for synthesis
- Product Code
- 3123
- Chemical Name
- 1-Methoxy-2-propanol
Regulatory Identifiers
- CAS Number
- 107-98-2 Check regulations →
- EC Number
- 203-539-1 Check regulations →
- REACH No.
- 01-2119457435-35-xxxx
Identified Uses
Laboratory chemical Laboratory and analytical use Formulation [mixing] of preparations and/or re-packaging (excluding alloys) Intermediate Industrial uses Professional uses
Uses advised against
Do not use for private purposes (household). Food, drink and animal feedingstuffs.
Manufacturers & Suppliers
Carl Roth GmbH + Co. KG
distributor
Schoemperlenstr. 3-5 D-76185 Karlsruhe Germany
+49 (0) 721 - 56 06 0
www.carlroth.de
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-Methoxy-2-propanol EC: 203-539-1 | 107-98-2 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air. In all cases of doubt, or when symptoms persist, seek medical advice.
Rinse skin with water/shower. In all cases of doubt, or when symptoms persist, seek medical advice.
Rinse cautiously with water for several minutes. In all cases of doubt, or when symptoms persist, seek medical advice.
Rinse mouth. Call a doctor if you feel unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water spray, alcohol resistant foam, dry extinguishing powder, BC-powder, carbon dioxide (CO₂)
water jet
Combustible. In case of insufficient ventilation and/or in use, may form flammable/explosive vapour-air mixture. Solvent vapours are heavier than air and may spread along floors. Places which are not ventilated, e.g. unventilated below ground level areas such as trenches, conduits and shafts, are particularly prone to the presence of flammable substances or mixtures. Vapours are heavier than air, spread along floors and form explosive mixtures with air. Vapours may form explosive mixtures with air.
Fight fire with normal precautions from a reasonable distance.
Firefighter Protection
In case of fire and/or explosion do not breathe fumes. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with skin, eyes and clothes. Do not breathe vapour/spray. Avoidance of ignition sources.
Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.
Absorb with liquid-binding material (sand, diatomaceous earth, acid- or universal binding agents). Place in appropriate containers for disposal.
Materials: liquid-binding material (sand, diatomaceous earth, acid- or universal binding agents)
Related Products
Similar products with comparable safety profiles
1-Methoxy-2-propanol
CAS: 107-98-2
2-Propanol 70 %, pure
CAS: 67-63-0
2-Methyl-1-propanol
CAS: 78-83-1
Acetone ≥99,5 %, for synthesis
CAS: 67-64-1
Acetone ≥99,5 %, for synthesis
CAS: 67-64-1
Ethylene glycol ≥99 %, for synthesis
CAS: 107-21-1
1-ethoxy-2-propanol
CAS: 1569-02-4
Diacetone alcohol ≥98 %, for synthesis
CAS: 123-42-2
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Provision of sufficient ventilation. Keep away from sources of ignition - No smoking. Take precautionary measures against static discharge.
Keep container tightly closed. Recommended storage temperature: 15 – 25 °C
Wash hands before breaks and after work. Keep away from food, drink and animal feedingstuffs. When using do not smoke.
Keep away from sources of ignition - No smoking. Take precautionary measures against static discharge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. The times are approximate values from measurements at 22 °C and permanent contact. Increased temperatures due to heated substances, body heat etc. and a reduction of the effective layer thickness by stretching can lead to a considerable reduction of the breakthrough time. If in doubt, contact manufacturer. At an approx. 1.5 times larger / smaller layer thickness, the respective breakthrough time is doubled / halved. The data apply only to the pure substance. When transferred to substance mixtures, they may only be considered as a guide. Type of material: NBR (Nitrile rubber). Material thickness: >0,11 mm. Breakthrough times of the glove material: >480 minutes (permeation: level 6).
Use safety goggle with side protection.
Respiratory protection necessary at: Aerosol or mist formation. Type: A (against organic gases and vapours with a boiling point of > 65 °C, colour code: Brown).
Keep away from drains, surface and ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The material is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
It's a reactive substance. Risk of ignition. If heated Risk of ignition. Vapours may form explosive mixtures with air.
Violent reaction with: strong oxidiser
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
There is no additional information.
Hazardous combustion products: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 3092
- Shipping Name
- 1-METHOXY-2-PROPANOL
- Transport Class
- 3
- Packing Group
- III
Provisions for dangerous goods (ADR) should be complied within the premises.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 1-Methoxy-2-propanol ≥99 %, for synthesis?
The signal word is warning.
What is the physical form of 1-Methoxy-2-propanol ≥99 %, for synthesis?
1-Methoxy-2-propanol ≥99 %, for synthesis is a liquid with colourless color. It has like ether odor.
What is the solubility of 1-Methoxy-2-propanol ≥99 %, for synthesis?
Water solubility: miscible in any proportion
What is 1-Methoxy-2-propanol ≥99 %, for synthesis used for?
Laboratory chemical Laboratory and analytical use Formulation [mixing] of preparations and/or re-packaging (excluding alloys) Intermediate Industrial uses Professional uses
What are the hazard statements for 1-Methoxy-2-propanol ≥99 %, for synthesis?
This substance has 2 hazard statements:
- H226: Flammable liquid and vapour
- H336: May cause drowsiness or dizziness
What is the melting point of 1-Methoxy-2-propanol ≥99 %, for synthesis?
The melting point is -96 °C and the boiling point is 120,2 °C.