NextSDS Logo
SI

SIGMATHERM 350 (SIGMATHERM SILACRYL)

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SIGMATHERM 350 (SIGMATHERM SILACRYL)

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
verf

Overview

SIGMATHERM 350 (SIGMATHERM SILACRYL) commonly used verf.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PPG Coatings SPRL/BVBA

manufacturer

๐Ÿ“

Noordersingel 23 B-2040 Borgerhout

๐ŸŒ

BE

๐Ÿ“ž

+32 3 3606470

๐Ÿ“ 

+32 3 3606435

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+31 20 4075210

๐ŸŒ

NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
n-butylacetaat
EC: 204-658-1
123-86-4 2.5-10% โš ๏ธ Hazardous
ethylacetaat
EC: 205-500-4
141-78-6 2.5-10% โš ๏ธ Hazardous
ethylmethylketon
EC: 201-159-0
78-93-3 2.5-10% โš ๏ธ Hazardous
xyleen
EC: 215-535-7
1330-20-7 20-25% โš ๏ธ Hazardous
Solventnafta (kool); Lichte olie, extractieresidu, hoogkokende fractie
EC: 266-013-0
65996-79-4 10-15% โš ๏ธ Hazardous

Composition Notes

De producent verklaart dat voor de in hoofdstuk 3 niet vermelde R-zinnen, de totale hoeveelheid gevaarlijke componenten beneden de grens liggen. Zie voor componenten met een wettelijke grenswaarde (MAC) hoofdstuk 8. Indien meerdere ingredienten met gelijke namen of nummers verschijnen hebben deze verschillende gevaren eigenschappen, bijvoorbeeld vlampunt.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Bij bewusteloosheid stabiele zijligging toepassen en medische advies inwinnen.

Symptoms:

Onregelmatige ademhaling of ademstilstand.

๐Ÿ–๏ธ Skin Contact

Verontreinigde kleding onmiddellijk uittrekken. De huid grondig wassen met water en zeep of een erkende huidreiniger.

๐Ÿ‘๏ธ Eye Contact

Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlenzen uitdoen. Medisch advies inwinnen.

๐Ÿฝ๏ธ Ingestion/Swallowing

Bij inslikken direkt arts raadplegen. Het slachtoffer laten rusten. GEEN braken opwekken.

๐Ÿšจ Immediate Medical Attention Required

Medische hulp dient te worden ingeroepen als de ziekteverschijnselen niet van voorbijgaande aard zijn of in geval van twijfel. Medisch advies inwinnen bij oogcontact of bewusteloosheid na inademing. Bij inslikken direct arts raadplegen. Medische hulp inroepen bij verbranding.

Medical Treatment

Kunstmatige beademing toepassen bij onregelmatige ademhaling of ademstilstand.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
viskeus
๐Ÿ‘ƒ Odor
kenmerkend
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
137 C
Critical Property
๐Ÿ”ฅ Flash Point
< 21C.0
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.21 g/cm3 bij 20 C
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
10.08 %(V) 434.83 g/m3
๐Ÿ“Š Lower Explosive Limit
1.54 %(V) 66.45 g/m3
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 300 C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ventilation must be present for spray particles and solvent vapors, especially in spray booths, to reduce concentrations below MAC value.

๐Ÿงค Hand Protection

For prolonged or repeated contact, use chemical-resistant gloves as per EN 374. Recommended gloves: Viton (R) with a minimum breakthrough time of 480 min. For long-term contact, a glove with protection class 6 (breakthrough time > 480 minutes) is recommended. For short contact, a glove with protection class 2 or higher (breakthrough time > 30 minutes) is recommended. The choice of gloves should consider all relevant workplace factors.

๐Ÿ‘๏ธ Eye Protection

Wearing chemical-resistant safety glasses (afsluitende bril) is mandatory.

๐Ÿ˜ท Respiratory Protection

In spray booths, employees must wear a fresh-air hood during spraying until concentrations fall below the MAC value. A P2A2 half-face combination mask is also specified.

๐Ÿฆบ Skin/Body Protection

Personnel must wear protective clothing. Work clothing should not consist of textile that shows dangerous melting behavior in case of fire. Wearing antistatic shoes is mandatory.

๐ŸŒ Environmental Exposure Controls

Refer to national legislation in chapter 15 for environmental protection regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1263

๐Ÿ“ฆ Proper Shipping Name

PAINT

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

II

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SIGMATHERM 350 (SIGMATHERM SILACRYL)?

The signal word for this substance is "no signal word".

What is SIGMATHERM 350 (SIGMATHERM SILACRYL) used for?

verf