NextSDS Logo
Me

Memosil 2

NO SIGNAL WORD Pasty SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Memosil 2

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Dental impression material

Overview

Memosil 2 commonly used dental impression material.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Kulzer GmbH

manufacturer

๐Ÿ“

Leipziger Strae 2, 63450 Hanau (Germany)

๐ŸŒ

DE

๐Ÿ“ž

+49 (0)800 4372522

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 (0)6132-84463

๐ŸŒ

DE

๐Ÿ•’

24-Hour-Number

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

2-component silicone impression material comprising base paste and matching catalyst paste for addition curing

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
octamethylcyclotetrasiloxane
EC: 209-136-7
556-67-2 3% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of symptoms.

๐Ÿ–๏ธ Skin Contact

Instantly wash with water and soap and rinse thoroughly.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse out mouth and then drink plenty of water. In case of persistent symptoms consult doctor.

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Medical Treatment

No further relevant information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Pasty
Critical Property
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
According to product specification
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Pasty
๐Ÿ‘ƒ Odor
Odourless
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
Not determined
Critical Property
๐Ÿ’จ Boiling Point
Not determined
Critical Property
๐Ÿ”ฅ Flash Point
191 C
Critical Property
๐Ÿ“Š Freezing Point
Not determined
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
Not determined.
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,1 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Not miscible or difficult to mix
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
0.0 g/l / 0.00 lb/gl
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Check protective gloves prior to each use for their proper condition. Recommended. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact of a maximum of 15 minutes gloves made of the following materials are suitable: Butyl rubber, BR; Nitrile rubber, NBR.

๐Ÿ‘๏ธ Eye Protection

Not absolutely necessary.

๐Ÿ˜ท Respiratory Protection

Not required.

๐Ÿฆบ Skin/Body Protection

Light weight protective clothing

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Memosil 2?

The signal word for this substance is "no signal word".

What is the physical form of Memosil 2?

Memosil 2 is a pasty with according to product specification color. It has odourless odor.

What is Memosil 2 used for?

Dental impression material

What is the melting point of Memosil 2?

The melting point is Not determined and the boiling point is Not determined.