Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Clear Dry HDP Plus
- Product Form
- Mixture
- Product Code
- 117151E
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Dishwash and rinse aid product; Automatic process
Uses advised against
Reserved for industrial and professional use.
Manufacturers & Suppliers
Ecolab Ltd.
manufacturer
PO Box 11; Winnington Avenue, Northwich, Cheshire, United Kingdom CW8 4DX
+44 (0)1606 74488
Emergency Contacts
Emergency Contact
+441618841235
Trans-European
+32-(0)3-575-5555
Poison Information Centre
0344 892 0111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Oxirane, methyl-, polymer with oxirane, mono(2-propylheptyl) ether | 166736-08-9 | 5 - 10% | Yes |
| Sodiumcumenesulphonate EC: 248-983-7 | 28348-53-0 | 1 - 2.5% | Yes |
| 2-Phosphono-1,2,4-Butanetricarboxylic Acid EC: 253-733-5 | 37971-36-1 | 1 - 2.5% | Yes |
| Alcohol ethoxylate | 68439-51-0 | 1 - 2.5% | Yes |
| Isotridecanol, ethoxylated EC: 500-241-6 | 69011-36-5 | 1 - 2.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Get medical attention if symptoms occur.
Rinse with plenty of water.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention.
Rinse mouth. Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
None known.
Not flammable or combustible.
In the event of fire and/or explosion do not breathe fumes.
Firefighter Protection
Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop leak if safe to do so. Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water.
For large spills, dike spilled material or otherwise contain material to ensure runoff does not reach a waterway.
Do not allow contact with soil, surface or ground water.
collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water.
Materials: non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Use only with adequate ventilation. Wash hands thoroughly after handling. In case of mechanical malfunction, or if in contact with unknown dilution of product, wear full Personal Protective Equipment (PPE).
Keep out of reach of children. Keep container tightly closed. Store in suitable labeled containers.
Handle in accordance with good industrial hygiene and safety practice. Remove and wash contaminated clothing before re-use. Wash face, hands and any exposed skin thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
No special protective equipment required. (EN 374)
Safety glasses with side-shields (EN 166)
None required if airborne concentrations are maintained below the exposure limit listed in Exposure Limit Information. Use certified respiratory protection equipment meeting EU requirements(89/656/EEC, (EU) 2016/425), or equivalent, when respiratory risks cannot be avoided or sufficiently limited by technical means of collective protection or by measures, methods or procedures of work organization. (EN 143, 14387)
No special protective equipment required. (EN 14605)
Consider the provision of containment around storage vessels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
No dangerous reaction known under conditions of normal use.
None known.
None known.
Depending on combustion properties, decomposition products may include following materials: Carbon oxides, Sulphur oxides, Oxides of phosphorus, metal oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Where possible recycling is preferred to disposal or incineration. If recycling is not practicable, dispose of contents/container in accordance with local regulations. Dispose of wastes in an approved waste disposal facility.
Where possible recycling is preferred to disposal or incineration. If recycling is not practicable, dispose of contents/container in accordance with local regulations. Dispose of wastes in an approved waste disposal facility.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Clear Dry HDP Plus?
The signal word is warning.
What is the physical form of Clear Dry HDP Plus?
Clear Dry HDP Plus is a liquid appearing as liquid with clear, pink color. It has very faint odor.
What is the solubility of Clear Dry HDP Plus?
Not applicable and/or not determined for the mixture
What is Clear Dry HDP Plus used for?
Dishwash and rinse aid product; Automatic process
What are the hazard statements for Clear Dry HDP Plus?
This substance has 1 hazard statement:
- H319: Causes serious eye irritation.
What is the melting point of Clear Dry HDP Plus?
The melting point is Not applicable and/or not determined for the mixture and the boiling point is Not applicable and/or not determined for the mixture.