NextSDS Logo
CL

CLEANLIFE Gertebenzin 2-Takt

DANGER liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
CLEANLIFE Gertebenzin 2-Takt

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Propellant Fuels

Overview

CLEANLIFE Gertebenzin 2-Takt commonly used propellant fuels.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger

Hazard Classifications

Flam. Liq. Category 1 H224
Skin Irr. Category 2 H315
STOT SE Category 3 H336
Asp. Tox. Category 1 H304
Aquatic Chronic Category 4 H413

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H224: Extremely flammable liquid and vapour.
  • H304: May be fatal if swallowed and enters airways.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H413: May cause long lasting harmful effects to aquatic life.

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor.
  • P331: Do NOT induce vomiting.
  • P370+P378: In case of fire: Use sand, carbon dioxide or powder extinguisher to extinguish.
  • P403+P233: Store in a well-ventilated place. Keep container tightly closed.
  • P403+P235: Store in a well-ventilated place. Keep cool.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

SCHARR FUELS GmbH company logo - Safety Data Sheet supplier organization

SCHARR FUELS GmbH

national supplier

๐Ÿ“

Gubener Strae 15 86156 Augsburg Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 821 242272-10

๐Ÿ“ 

+49 821 242272-50

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Description of the mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Naphtha (petroleum), full range alkylate, butane contg.
EC: 271-267-0
68527-27-5 50-75% โš ๏ธ Hazardous
Hydrocarbons, C5, C5-6 rich
EC: 270-690-8
68476-50-6 25-50% โš ๏ธ Hazardous
2 Takt l N/A 1-5% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. In case of respiratory tract irritation, consult a physician. Provide fresh air.

Symptoms:

Respiratory tract irritation, breathing difficulties, headache, vertigo.

๐Ÿ–๏ธ Skin Contact

Wash with plenty of soap and water.

๐Ÿ‘๏ธ Eye Contact

Remove contact lenses, if present and easy to do. Continue rinsing. Irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth with water (only if the person is conscious). Do NOT induce vomiting. Call a physician immediately.

๐Ÿšจ Immediate Medical Attention Required

If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. Call a physician immediately (for ingestion). Subsequent observance for pneumonia and pulmonary oedema. Supervise the blood circulation.

Medical Treatment

Subsequent observance for pneumonia and pulmonary oedema.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
greenish-blue
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
characteristic
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
not determined
๐ŸงŠ Melting Point
<-60 C
Critical Property
๐Ÿ’จ Boiling Point
30 200 C at 1.013 hPa
Critical Property
๐Ÿ”ฅ Flash Point
<0 C
Critical Property
๐Ÿ“Š Freezing Point
<-60 C
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
not determined
๐Ÿ’จ Vapor Pressure
50 65 kPa at 38 C
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
0,68 0,72 at 15 C (water = 1)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
not determined
Critical Property
๐Ÿ”ฅ Flammability
flammable liquid in accordance with GHS criteria
๐Ÿ“Š Upper Explosive Limit
7,6 vol%
๐Ÿ“Š Lower Explosive Limit
1,4 vol%
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
400 C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
>6
๐Ÿ“Š Solubility In Water
<50 [mg] / l at 20 C
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
<1 [mm] / s at 38 C
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

General ventilation.

๐Ÿงค Hand Protection

Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. Check leaktightness/impermeability prior to use. In the case of wanting to use the gloves again, clean them before taking off and air them well. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. type of material PE: polyethylene, CR: chloroprene (chlorobutadiene) rubber, IIR: isobutene-isoprene (butyl) rubber - material thickness - 0,35 mm - breakthrough times of the glove material 0,4 mm >120 minutes (permeation: level 4)

๐Ÿ‘๏ธ Eye Protection

Wear eye/face protection.

๐Ÿ˜ท Respiratory Protection

[In case of inadequate ventilation] wear respiratory protection. Combination filtering device (EN 141).

๐Ÿฆบ Skin/Body Protection

Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended. Wash hands thoroughly after handling.

๐ŸŒ Environmental Exposure Controls

Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 1203

๐Ÿ“ฆ Proper Shipping Name

GASOLINE

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

II

๐Ÿš› ADR Transport Precautions

Provisions for dangerous goods (ADR) should be complied within the premises.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for CLEANLIFE Gertebenzin 2-Takt?

The signal word for this substance is "danger".

What is the physical form of CLEANLIFE Gertebenzin 2-Takt?

CLEANLIFE Gertebenzin 2-Takt is a liquid with greenish-blue color. It has characteristic odor.

What is CLEANLIFE Gertebenzin 2-Takt used for?

Propellant Fuels

What are the hazard statements for CLEANLIFE Gertebenzin 2-Takt?

This substance has 5 hazard statements: H224: Extremely flammable liquid and vapour. H304: May be fatal if swallowed and enters airways. H315: Causes skin irritation. H336: May cause drowsiness or dizziness. H413: May cause long lasting harmful effects to aquatic life.

What is the melting point of CLEANLIFE Gertebenzin 2-Takt?

The melting point is <-60 C and the boiling point is 30 200 C at 1.013 hPa.