NextSDS Logo
RE

REFINAL 352XF

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
REFINAL 352XF

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Manufacture of basic metals, including alloys. Manufacture of fabricated metal products, except machinery and equipment.

Overview

REFINAL 352XF commonly used manufacture of basic metals, including alloys. manufacture of fabricated metal products, except machinery and equipment..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P280: Wear protective gloves/ eye protection/ face protection.
  • P501: Dispose of contents/container in accordance with local regulation.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

ACT LIMITED

national supplier

๐Ÿ“

Grosvenor House 11 St Paul's Square, Birmingham B3 1RB

๐ŸŒ

GB

๐Ÿ“ž

+44 (0) 121 684 0175

๐Ÿ“ 

+44 (0) 121 242 6422

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

112

๐Ÿ•’

24 hours per day, 7 days per week.

ACT LIMITED

๐Ÿ“ž

+44 (0) 121 247 9447

๐ŸŒ

GB

๐Ÿ•’

24 hours per day, 7 days per week.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

Mixture of KCl, MgCl2, CaF2 and NaCl

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Magnesium chloride
EC: 232-094-6
7786-30-3 33-38% โš ๏ธ Hazardous
Sodium chloride
EC: 231-598-3
7647-14-5 23-29% โš ๏ธ Hazardous
Potassium chloride
EC: 231-211-8
7447-40-7 19-23% โš ๏ธ Hazardous
Calcium fluoride
EC: 238-575-7
14542-23-5 2-18% โš ๏ธ Hazardous

Composition Notes

For the full text of the R-phrases mentioned in this Section, see Section 16. For the full text of the H-Statements mentioned in this Section, see Section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air. If symptoms persist, call a physician.

๐Ÿ–๏ธ Skin Contact

Carefully and gently brush the contaminated body surfaces in order to remove all traces of product. Wash affected area immediately with plenty of water. Remove contaminated clothing. Consult a physician

๐Ÿ‘๏ธ Eye Contact

In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Rinse thoroughly with plenty of water, also under the eyelids. Consult a physician

๐Ÿฝ๏ธ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician

๐Ÿšจ Immediate Medical Attention Required

When symptoms persist or in all cases of doubt, seek medical advice. Follow the advice given in section 4.1.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
grey
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
solid
๐Ÿ‘ƒ Odor
slight
๐Ÿ“Š Odor Threshold
Not applicable
๐Ÿงช Ph
Follow up studies are ongoing.
๐ŸงŠ Melting Point
380 - 480 C
Critical Property
๐Ÿ’จ Boiling Point
Not applicable (solid with a melting point > 450C)
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable
๐Ÿ’จ Vapor Pressure
Not applicable
๐Ÿ“Š Vapor Density
Not applicable
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
0,9 - 1,1 g/cm3
โš–๏ธ Density
1,7 - 2,6 g/cm3; Calculation method
Critical Property
๐Ÿ”ฅ Flammability
The product is not flammable.
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not applicable
๐Ÿ“Š Decomposition Temperature
Not applicable
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
no data available
๐Ÿ“Š Solubility In Water
soluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not applicable
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Handling systems should preferably be enclosed or suitable ventilation installed to maintain atmospheric dust below the OES, if not wear suitable protective equipment.

๐Ÿงค Hand Protection

Heat resistant gloves

๐Ÿ‘๏ธ Eye Protection

Safety glasses with side-shields Do not wear contact lenses.

๐Ÿ˜ท Respiratory Protection

Use appropriate respiratory protection against particles according to the risk level. Recommended Filter type: P2 filter

๐Ÿฆบ Skin/Body Protection

Use clothing fully covering skin, full length pants, long sleeved overalls, with close fittings at openings. Footwear resistant to caustics and avoiding dust penetration.

๐ŸŒ Environmental Exposure Controls

All ventilation systems should be filtered before discharge to atmosphere.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

not regulated

๐Ÿ“ฆ Proper Shipping Name

not regulated

โš ๏ธ Transport Hazard Class

not regulated

๐Ÿ“‹ Packing Group

not regulated

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for REFINAL 352XF?

The signal word for this substance is "no signal word".

What is REFINAL 352XF used for?

Manufacture of basic metals, including alloys. Manufacture of fabricated metal products, except machinery and equipment.

What is the melting point of REFINAL 352XF?

The melting point is 380 - 480 C and the boiling point is Not applicable (solid with a melting point > 450C).