Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
FIBROUS MASTIC FILL BIO SW 607 HT and FILL BIO SW PLUS is a light gray paste substance commonly used high density biosoluble fibrous mastic for elevated temperatures, useful for grouting or gluing on refractory products in general, such as: - refractory bricks (dense and/or insulating); - cavities created between the carpentry and the insulation of thermal plants (industrial furnaces, boilers, etc.). specific for repairing industrial heating systems (furnaces, boilers, etc.) with conduction at maximum temperatures of 1100c for plus and 1200c for ht.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
SIM s.r.l. Socio unico
manufacturer
REFRATTARI GENERALI S.r.l.
distributor
Via Giovanni XXIII 19 20014 Nerviano (MI), Italy
IT
+39 0331 58.56.82
+39 0331 58.43.63
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
118
IT
SIM s.r.l. Socio unico
+39 02.97.25.03.29
IT
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
substanceGeneral Composition
biosoluble flock, marking Thermal Ceramics (Cas.436083-99-7) colloidal silica (Cas. n. EEC n. non-dangerous) disinfectant, water.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| biosoluble flock | 436083-99-7 | Not specified | โ Non-hazardous |
| colloidal silica | N/A | Not specified | โ Non-hazardous |
| disinfectant | N/A | Not specified | โ Non-hazardous |
| water | N/A | Not specified | โ Non-hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
take the person outdoors, give water to drink to clear the throat and let blow the nose.
๐๏ธ Skin Contact
rinse the affected areas with soap and water thoroughly. Do not use detergents.
๐๏ธ Eye Contact
rinse thoroughly with water and have a special eye drops available. Don't rub your eyes.
๐ฝ๏ธ Ingestion/Swallowing
drink plenty of water.
๐จ Immediate Medical Attention Required
It is not required the immediate medical assistance. Consult a doctor if symptoms persist. If possible, show this Safety Data Sheet to the doctor in attendance.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐งค Hand Protection
Wear industrial leather gloves
๐๏ธ Eye Protection
As necessary, wear goggles or safety glasses with side shields.
๐ท Respiratory Protection
For dust concentrations below the applicable exposure limit value, RPE is not required but FFP2 respirators should be provided for use on a voluntary basis. For short term operations where excursions are less than ten times the applicable limit value, use FFP2 respirators. In case of higher concentrations or where the concentration is not known, please contact our company and/or your supplier REFRATTARI GENERALI (manufactured by SIM S.r.l.).
๐ฆบ Skin/Body Protection
Wear work clothes, which are loose fitting at the neck and wrists.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for FIBROUS MASTIC FILL BIO SW 607 HT and FILL BIO SW PLUS?
The signal word for this substance is "no signal word".
What is the solubility of FIBROUS MASTIC FILL BIO SW 607 HT and FILL BIO SW PLUS?
Less than 1 mg/l
What is FIBROUS MASTIC FILL BIO SW 607 HT and FILL BIO SW PLUS used for?
High density biosoluble fibrous mastic for elevated temperatures, useful for grouting or gluing on refractory products in general, such as: - refractory bricks (dense and/or insulating); - cavities created between the carpentry and the insulation of thermal plants (industrial furnaces, boilers, etc.). Specific for repairing industrial heating systems (furnaces, boilers, etc.) with conduction at maximum temperatures of 1100C for PLUS and 1200C for HT
What is the melting point of FIBROUS MASTIC FILL BIO SW 607 HT and FILL BIO SW PLUS?
The melting point is SW PLUS > 1200C / SW 607 HT > 1300 C and the boiling point is Not applicable.