Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Drgersorb 800 Plus / CLIC Absorber 800+ / Infinity ID CLIC Absorber 800+ commonly used absorber for carbon dioxide in anesthesia equipment/devices..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Drger Medical GmbH
manufacturer
Moislinger Allee 53-55 D-23560 Lbeck
DE
+49 451/882-0
+49 451/882-2080
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+49 451/882-2395
DE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Drger soda lime containing calcium dihydroxide, sodium hydroxide, 14-18 % water and the indicator ethyl violet.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Calcium dihydroxide (Ca(OH) 2 ) EC: 215-137-3 | 1305-62-0 | 78-84% | โ ๏ธ Hazardous |
| Sodium hydroxide EC: 215-185-5 | 1310-73-2 | 2-4% | โ ๏ธ Hazardous |
| Ethylviolet EC: 219-231-5 | 2390-59-2 | 0.1% | โ ๏ธ Hazardous |
Composition Notes
Drger soda lime contents no ozone-depleting chemicals and no volatile organic chemicals (VOCs). During the manufacturing process for Drger soda lime no ozone-depleting chemicals and no volatile organic chemicals (VOCs) were used.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Fresh air. Consult physician.
๐๏ธ Skin Contact
Wash with plenty of water, then treat with polyethylene glycol 400. Discard any shoes or clothing items that cannot be decontaminated.
๐๏ธ Eye Contact
Immediately flush eyes with plenty of water (for at least 15 minutes), while holding eyelids open. Seek medical advice at once.
Symptoms:
Danger of corneal clouding.
๐ฝ๏ธ Ingestion/Swallowing
Administer lemon juice and afterwards plenty of water. Do not induce vomiting (Danger of perforation).
Symptoms:
Danger of perforation (oesophagus and stomach).
๐จ Immediate Medical Attention Required
Consult physician/seek medical advice at once. After ingestion there is a danger of the oesophagus and the stomach becoming perforated.
Medical Treatment
After ingestion there is a danger of the oesophagus and the stomach becoming perforated.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Handling according to the Instructions for Use.
๐งค Hand Protection
Prophylactic skin protection is recommended. Wash thoroughly after handling. Skin care. In case of accidents use suitable protective gloves made from Latex or Polychloropren (nitrile, butyl, Viton). Please observe the glove manufacturers instructions on permeability and rupture times as well as the specific workplace conditions.
๐๏ธ Eye Protection
Safety goggles necessary.
๐ท Respiratory Protection
Not necessary as Drger soda lime is delivered in pelletform. When dust occur, use a dust mask with FFP2 filter.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Drgersorb 800 Plus / CLIC Absorber 800+ / Infinity ID CLIC Absorber 800+?
The signal word for this substance is "no signal word".
What is the solubility of Drgersorb 800 Plus / CLIC Absorber 800+ / Infinity ID CLIC Absorber 800+?
1 g/l
What is Drgersorb 800 Plus / CLIC Absorber 800+ / Infinity ID CLIC Absorber 800+ used for?
Absorber for carbon dioxide in anesthesia equipment/devices.