NextSDS Logo
Di

Diethylene glycol

WARNING liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Diethylene glycol

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial use

Overview

Diethylene glycol is a clear, transparent substance commonly used industrial use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning

Hazard Classifications

Acute Tox. Category 4 H302
STOT RE Category 2 H373

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Harmful if swallowed.
  • H373: May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

  • P260: Do not breathe dust/fume/gas/mist/vapors/spray.
  • P264: Wash thoroughly after handling.
  • P270: Do not eat, drink or smoke when using this product.
  • P314: Get medical advice/attention if you feel unwell.
  • P330: Rinse mouth.
  • P501: Dispose of contents/container to industrial combustion plant.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Industrias Derivadas del Etileno S.A. de C.V. company logo - Safety Data Sheet supplier organization

Industrias Derivadas del Etileno S.A. de C.V.

manufacturer

๐Ÿ“

Km. 4.2 Blvd. Morelos, Col. Complejo Petroqumico Morelos, 96400 Coatzacoalcos, Veracruz Mexico

๐ŸŒ

MX

๐Ÿ“ž

+52 921-211-9000 / +52 921-268-2036

๐ŸŒ www.grupoidesa.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

SETIQ

๐Ÿ“ž

01-800-00-21400

๐ŸŒ

MX

CHEMTREC

๐Ÿ“ž

800-424-930

๐ŸŒ

US

CANUTEC

๐Ÿ“ž

613-996-66660

๐ŸŒ

CA

Emergency Contact

๐Ÿ“ž

(55) 5559 1588

๐ŸŒ

MX

๐Ÿ’ก

Cd. de Mxico.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
DIETHYLENE GLYCOL 111-46-6 Not specified โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. Provide fresh air.

๐Ÿ–๏ธ Skin Contact

Wash with plenty of soap and water.

๐Ÿ‘๏ธ Eye Contact

Remove contact lenses, if present and easy to do. Continue rinsing. Irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth with water (only if the person is conscious). Do NOT induce vomiting.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Clear, Transparent
๐ŸŽจ Colour
Clear, Transparent
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Practically Odorless
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
6 8 (200 [g] / l, 20 C)
๐ŸงŠ Melting Point
-6 C
Critical Property
๐Ÿ’จ Boiling Point
244 C at 760 mmHg
Critical Property
๐Ÿ”ฅ Flash Point
138 C at 760 mmHg
Critical Property
๐Ÿ“Š Freezing Point
-6 C
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
not determined
๐Ÿ’จ Vapor Pressure
0.008 hPa at 25 C
๐Ÿ“Š Vapor Density
this information is not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.12 [g] / cm at 25 C
Critical Property
๐Ÿ”ฅ Flammability
not relevant (fluid)
๐Ÿ“Š Upper Explosive Limit
10.8 vol%
๐Ÿ“Š Lower Explosive Limit
1.6 vol%
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
228 C (ECHA)
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
- n-octanol/water (log KOW) (ECHA) - Soil organic carbon/water (log KOC) 0 (ECHA)
๐Ÿ“Š Solubility In Water
miscible in any proportion Hygroscopic Liquid.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
30 mPa s at 25 C
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

General ventilation.

๐Ÿงค Hand Protection

Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. Check leaktightness/impermeability prior to use. In the case of wanting to use the gloves again, clean them before taking off and air them well. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves.

๐Ÿ‘๏ธ Eye Protection

Wear eye/face protection.

๐Ÿ˜ท Respiratory Protection

In case of inadequate ventilation wear respiratory protection.

๐ŸŒ Environmental Exposure Controls

Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

โš ๏ธ Transport Hazard Class

Class

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Diethylene glycol?

The signal word for this substance is "warning".

What is the physical form of Diethylene glycol?

Diethylene glycol is a liquid appearing as clear, transparent with clear, transparent color. It has practically odorless odor.

What is Diethylene glycol used for?

Industrial use

What are the hazard statements for Diethylene glycol?

This substance has 2 hazard statements: H302: Harmful if swallowed. H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of Diethylene glycol?

The melting point is -6 C and the boiling point is 244 C at 760 mmHg.