NextSDS Logo
RT

RTD LIQUID

WARNING Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
RTD LIQUID
Product Form
Mixture

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
D1A0-30EW-U008-TA5R

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Industrial use,Professional use, Lubricants, Greases and Release Products

Overview

RTD LIQUID commonly used industrial use,professional use, lubricants, greases and release products.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Lact. H362
Aquatic Acute Category 1 H400
Aquatic Chronic Category 1 H410

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H362: May cause harm to breast-fed children.
  • H410: Very toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P260: Do not breathe dusts or mists.
  • P263: Avoid contact during pregnancy and while nursing.
  • P280: Wear protective clothing, eye protection, face protection.
  • P308+P313: IF exposed or concerned: Get medical advice/attention.
  • P501: Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

ROCOL a division of ITW Ltd company logo - Safety Data Sheet supplier organization

ROCOL a division of ITW Ltd

manufacturer

๐Ÿ“

Rocol House Wakefield Rd, Swillington GB LS26 8BS Leeds West Yorkshire United Kingdom

๐ŸŒ

GB

๐ŸŒ www.rocol.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ROCOL a division of ITW Ltd

๐Ÿ“ž

+44 (0)113 232 2600

๐ŸŒ

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
C14-C17 CHLORINATED PARAFFIN
EC: 287-477-0
85535-85-9 70% โš ๏ธ Hazardous
TERPINEOL
EC: 232-268-1
8000-41-7 0.1-1% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Allow affected person to breathe fresh air. Allow the victim to rest.

๐Ÿ–๏ธ Skin Contact

Wash skin with plenty of water. If skin irritation occurs: Get medical advice/attention.

Symptoms:

skin irritation

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists.

Symptoms:

pain, blinking or redness

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
characteristic
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
No data available
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
- 100 C
Critical Property
๐Ÿ“Š Freezing Point
No data available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
No data available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1.1
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Non flammable
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 200 C
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
insoluble in water
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
insoluble in water
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
0 g/l
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
No data available
๐Ÿ“Š Kinematic Viscosity
110 mm/s
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Wear protective gloves. Nitrile rubber gloves

๐Ÿ‘๏ธ Eye Protection

Chemical goggles or safety glasses

๐Ÿ˜ท Respiratory Protection

Not required for normal conditions of use. In case of insufficient ventilation, wear suitable respiratory equipment. Wear a respirator conforming to EN140 with Type A filter or better

๐ŸŒ Environmental Exposure Controls

Avoid contact during pregnancy/while nursing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 3082

๐Ÿ“ฆ Proper Shipping Name

ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

Special provisions for carriage - Packages (ADR) : V12; Special provisions for carriage - Loading, unloading and handling (ADR) : CV13

๐Ÿšข IMDG Maritime Transport Precautions

Stowage category (IMDG) : A

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for RTD LIQUID?

The signal word for this substance is "warning".

What is the physical form of RTD LIQUID?

RTD LIQUID is a liquid with brown color. It has characteristic odor.

What is the solubility of RTD LIQUID?

insoluble in water

What is RTD LIQUID used for?

Industrial use,Professional use, Lubricants, Greases and Release Products

What are the hazard statements for RTD LIQUID?

This substance has 2 hazard statements: H362: May cause harm to breast-fed children. H410: Very toxic to aquatic life with long lasting effects.

What is the melting point of RTD LIQUID?

The melting point is No data available and the boiling point is No data available.