Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Cooling medium for recooling (Chiller) systems 1:4 Standard
- Product Code
- 3301960 / 3301965 / 3301967
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 8T3N-W0UX-A00P-E9XM
Identified Uses
Anti-freezing agents
Manufacturers & Suppliers
Rittal GmbH & Co. KG
manufacturer
Auf dem Stützelberg, D-35745 Herborn
+49 2772 505 9052
Emergency Contacts
Germany
+49 800 5121 5121
24 h
National Toxicology Center
+359 2 9154 409
7/5
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanediol EC: 203-473-3 | 107-21-1 | 20 - 30% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If symptoms call a physician.
Wash off immediately with plenty of water. If symptoms call a physician.
Rinse thoroughly with plenty of water, also under the eyelids. Consult a physician.
Rinse mouth with water. Immediately give plenty of water (if possible charcoal slurry). Never give anything by mouth to an unconscious person. If a person vomits when lying on his back, place him in the recovery position. Call a physician immediately.
Immediate Medical Attention
Call a physician immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water spray, Carbon dioxide (CO2), Alcohol-resistant foam, Dry powder
High volume water jet
Combustible liquid. Vapors may produce explosive mixtures with air at temperatures over the flash point. Keep containers cool by spraying with water if exposed to fire, Heating will cause a pressure rise - with risk of bursting, Heating or fire can release toxic gas.
Cool closed containers exposed to fire with water spray.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Provide adequate ventilation. Keep away from heat and sources of ignition. Avoid contact with the skin and the eyes.
Do not flush into surface water or sanitary sewer system. Avoid subsoil penetration. Local authorities should be advised if significant spillages cannot be contained.
Absorb with liquid-binding material. Flush away residuals with plenty of water.
Materials: liquid-binding material (sand, diatomite, acid binders, universal binders)
Related Products
Similar products with comparable safety profiles
Coolant VCS ready mixed mix 40/60
---
Refrigerants Standard Mix in Methanol
---
Triple QX Blue Coolant Ready Mix -36°C
---
MPM Coolant Premium Longlife -40°C G13 Ready to Use
UFI: QSKQ-5GAP-320Q-7KES
-40°C Acwel Organic Acid Coolant
---
REFRIGERANT R424A
---
Cooling spray Medicool
---
High-performance cooling lubricant concentrate E-COLL
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep container tightly closed. Handle and open container with care. Provide sufficient air exchange and/or exhaust in work rooms. Emergency eye wash fountains and emergency showers should be available in the immediate vicinity.
Keep container tightly closed. Keep in a well-ventilated place. Keep away from heat. Store in cool place. Keep in a dry place. Product is hygroscopic. Keep in an area equipped with solvent resistant flooring.
Take off all contaminated clothing immediately. Do not breathe gas/fumes/vapour/spray. Avoid contact with the skin and the eyes. Smoking, eating and drinking should be prohibited in the application area. Keep away from food, drink and animal feedingstuffs. Wash hands before breaks and at the end of workday.
Combustible liquid. Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Refer to protective measures listed in sections 7 and 8.
Protective gloves complying with EN 374. Recommended Material: butyl-rubber. Break through time: >= 480 min. Glove thickness: 0,7 mm. Protective gloves should be replaced at first signs of wear.
Tightly fitting safety goggles
In case of insufficient ventilation, wear suitable respiratory equipment. Required, if exposure limit is exceeded (e.g. OEL). Required if vapours or aerosol are released. In case of brief exposure or low pollution use breathing filter apparatus. In case of intensive or longer exposure use breathing apparatus that is independent of circulating air. Recommended Filter type: Combination filter: A-P2
Wear personal protective equipment.
Do not flush into surface water or sanitary sewer system. Avoid subsoil penetration. Local authorities should be advised if significant spillages cannot be contained.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No decomposition if stored and applied as directed.
Reacts with alkalies. Incompatible with oxidizing agents.
Keep away from heat and sources of ignition. Keep away from direct sunlight.
Oxidizing agents, Strong acids and strong bases
Carbon oxides, Under certain fire conditions, traces of other toxic products cannot be excluded.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Can be incinerated, when in compliance with local regulations.
Disposal together with normal waste is not allowed. Do not let product enter drains.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not applicable.
- Shipping Name
- Not applicable.
- Transport Class
- Not applicable.
- Packing Group
- Not applicable.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product, delivered to the European Economic Area, is compliant with Regulation (EC) 1907/2006 (REACH) as every substance/monomer it is composed of is excluded from regulation or exempted from registration or have been registered in the supply chain.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Cooling medium for recooling (Chiller) systems 1:4 Standard?
The signal word is warning.
What is the physical form of Cooling medium for recooling (Chiller) systems 1:4 Standard?
Cooling medium for recooling (Chiller) systems 1:4 Standard is a liquid with light yellow color. It has characteristic odor.
What is Cooling medium for recooling (Chiller) systems 1:4 Standard used for?
Anti-freezing agents
What are the hazard statements for Cooling medium for recooling (Chiller) systems 1:4 Standard?
This substance has 1 hazard statement:
- H373: May cause damage to organs (Kidney) through prolonged or repeated exposure.