NextSDS Logo
Xp

Xpert Omni MTB/RIF Ultra

DANGER Liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Xpert Omni MTB/RIF Ultra
Product Code
GXMTB/RIF-10; GXMTB/RIF-50; GXMTB/RIF-CN-10; GXMTB/RIF-US-10; GXMTB/RIF-JP-10; CGXMTB/RIF-10; CGXMTB/RIF-50; GXMTB/RIF-ULTRA-10; GXMTB/RIF-ULTRA-50; GXMTB/RIF-IN-10; CGXMTB/RIF-IN-50; 900-0772; GXMTB/RIF-ULT-SA50; GXMTB/RIF-MII-10; GXMTB/RIF-MII-50; 900-0779; 900-0811; RMTB/XDR-10; GXMTB-ULTRA-MII-10; GXMTB-ULTRA-MII-50; GXMTB/XDR-10; 900-0888; OMNIMTB/RIF-ULT-10;GXMTBRIF-ULT-CN-10; GXMTBRIF-ULT-CN-50

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory use

Overview

Xpert Omni MTB/RIF Ultra is a beads are solid white components in cartridges; reagents are clear liquids which are primarily buffered in aqueous solutions. components are odorless. substance commonly used laboratory use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (DANGER)

Hazard Classifications

Flam. Liq. Category 3 H226
Skin Corr. Category 1B H314

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapour
  • H314: Causes severe skin burns and eye damage.
  • H318: Causes serious eye damage
  • Suspected of causing genetic defects.
  • Suspected of damaging fertility or the unborn child.
  • May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

  • P210: Keep away from heat, sparks, open flames and/or hot surfaces. - No smoking.
  • P233: Keep container tightly closed.
  • P260: Do not breathe mists, vapours, and/or spray.
  • P264: Wash thoroughly after handling.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
  • P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
  • P304+P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P310: Immediately call a POISON CENTER or doctor/physician.
  • P321: Specific treatment, see supplemental first aid information.
  • P363: Wash contaminated clothing before reuse.
  • P370+P378: In case of fire: Use appropriate media for extinction.
  • P501: Dispose of content and/or container in accordance with local, regional, national, and/or international regulations.
  • Obtain special instructions before use.
  • Do not handle until all safety precautions have been read and understood.
  • Use personal protective equipment as required.
  • IF exposed or concerned: Get medical advice/attention.
  • Get medical advice/attention if you feel unwell.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Cepheid company logo - Safety Data Sheet supplier organization

Cepheid

manufacturer

904 Caribbean Drive Sunnyvale, CA 94089 United States

US

(888) 838-3222 - US Option 2; 1 (408) 541-4191 - Outside of the US

Cepheid AB company logo - Safety Data Sheet supplier organization

Cepheid AB

distributor

Rntgenvgen 5 SE-171 54 Solna Sweden

SE

+33 563 825 319 - EU

Cepheid India Private Limited company logo - Safety Data Sheet supplier organization

Cepheid India Private Limited

distributor

1, SIPCOT Industrial Growth Centre, Oragadam, Kanchipuram, Tamil Nadu - 602 105, India

IN

+91 11 48353010

Cepheid Holdings Pty Ltd company logo - Safety Data Sheet supplier organization

Cepheid Holdings Pty Ltd

distributor

Suite 2, Level 3, Building A 11 Talavera Road Macquarie Park, NSW 2113 Australia

AU

1800 107 884

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

INFOTRAC

1 (800) 535-5053

US

24 hr Emergency

Emergency Contact

1 (352) 323-3500

US

Outside of the US

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

Material does not meet the criteria of a substance in accordance with Regulation (EC) No 1272/2008.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Isopropylique Alcohol
EC: 200-661-7
67-63-0 10-15% Hazardous
Sodium Hydroxide (NaOH)
EC: 215-185-5
1310-73-2 5-8% Hazardous

Additional Information

Safety Data Sheet Effective Date: 2023-06 Supersedes: 2022-4 Xpert MTB/RIF Xpert MTB/RIF Ultra Xpert MTB/XDR Xpert Omni MTB/RIF Ultra

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Remove to fresh air. Administer oxygen if breathing is difficult. Give artificial respiration if victim is not breathing. If signs/symptoms continue, get medical attention.

Skin Contact

Wash skin with soap and water. Get medical attention.

Eye Contact

Hold eye open and rinse slowly and gently with water for 15-20 minutes. Remove contact lenses, if present, after the first five minutes, then continue rinsing eye. Get medical attention.

Ingestion/Swallowing

Rinse mouth. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention Required

All treatments should be based on observed signs and symptoms of distress in the patient.

Medical Treatment

All treatments should be based on observed signs and symptoms of distress in the patient.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Use water spray (fog), foam, dry powder, or carbon dioxide.

Unsuitable Extinguishing Media

No data available

Specific Fire Hazards

This material is classified flammable, however it is in small vials and is unlikely to cause significant flammability hazard in use.

Firefighter Protection Equipment

Fire fighters should wear complete protective clothing including self-contained breathing apparatus.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

No emergency procedures are expected to be necessary if material is used under ordinary conditions as recommended.

Small Spill Procedures

For small spills, wear gloves and absorb spill with paper towel. Do not dispose spilled materials down drain.

Environmental Precautions

Prevent entry into waterways, sewers, basements or confined areas.

Cleanup Methods

absorb spill with paper towel.

Cleanup Materials:

paper towel

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Evaporation Rate
Data lacking
Odor
Data lacking
Form
Not available
Cloud Point
Not available
Metal Corrosion
Not available
Appearance
Beads are solid white components in cartridges; reagents are clear liquids which are primarily buffered in aqueous solutions. Components are odorless.
Ph
> 12.5
Vapor Density
Data lacking
Physical State Data
liquid
Crystallisation Point
Not available
Melting Point
Data lacking
Critical Property
Boiling Point
Data lacking
Critical Property
Solidification Point
Not available
Auto Ignition Temperature
No data available
Odor Threshold
Data lacking
Kinematic Viscosity
Not available
Physical State
Liquid
Critical Property
Density
Not available
Upper Explosive Limit
No data available
Decomposition Temperature
Data lacking
Explosive Limits
Not available
Freezing Point
Data lacking
Molecular Weight
Not available
Properties Status
Not available
Flash Point
Sample Reagent: 20
Critical Property
Voc Content
Not available
Vapor Pressure
Data lacking
Colour
White/clear
State Under Standard Conditions
Not available
Solubility In Water
Data lacking
Dynamic Viscosity
Not available
Lower Explosive Limit
No data available
Bulk Density
Not available
Solubility
Not available
Softening Point
Not available
Colour Intensity
Not available
Solubility In Fat
Not available
Relative Density
Data lacking
Flammability
No data available
Relative Evaporation Rate
Not available
Partition Coefficient
Data lacking
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Use good safety and industrial hygiene practices.

Use appropriate Personal Protective Equipment (PPE).

Avoid contact with skin and eyes.

Storage Conditions

Store according to product labeling.

General Hygiene Measures

Wash thoroughly with soap and water after handling and before eating, drinking, or using tobacco.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Eye Protection

Wear chemical splash safety goggles.

Respiratory Protection

Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or symptoms are experienced.

Skin/Body Protection

Wear protective clothing

Environmental Exposure Controls

Follow best practice for site management and disposal of waste.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stable under normal temperatures and pressures.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous Reactions

Isopropyl alcohol may form explosive mixture in air. For all other ingredients, no potential for hazardous reactions identified.

Conditions to Avoid

Heat, flames, sparks.

Incompatible Materials

Acids, oxidizing agents.

Section 12

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

Toxicity

Sample reagent containing sodium hydroxide > 12.5 pH has the potential for harmful effects in the environment if not properly disposed.
Sample reagent containing sodium hydroxide > 12.5 pH has the potential for harmful effects in the environment if not properly disposed.

Persistence and Degradability

Material data lacking.
Material data lacking.

Bioaccumulative Potential

Material data lacking.
Material data lacking.

Mobility in Soil

Material data lacking.
Material data lacking.

Results of PBT and vPvB assessment

No PBT and vPvB assessment has been conducted.
No PBT and vPvB assessment has been conducted.

Other Adverse Effects

No studies have been found.
No studies have been found.
Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Waste Treatment Methods

Dispose of content and/or container in accordance with local, regional, national, and/or international regulations.

Product Disposal Recommendations

Dispose of content and/or container in accordance with local, regional, national, and/or international regulations.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN2920

Proper Shipping Name

Corrosive liquids, flammable, n.o.s. (sodium hydroxide, isopropanol)

Transport Hazard Class

8,3

Packing Group

II

IMDG Maritime Transport Precautions

None specified.

IATA Air Transport Precautions

None specified.

Section 15

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

Additional Regulatory Information

SARA Hazard Classifications Acute, Chronic, Fire

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Xpert Omni MTB/RIF Ultra?

The signal word for this substance is "danger".

What is the physical form of Xpert Omni MTB/RIF Ultra?

Xpert Omni MTB/RIF Ultra is a liquid appearing as beads are solid white components in cartridges; reagents are clear liquids which are primarily buffered in aqueous solutions. components are odorless. with white/clear color. It has data lacking odor.

What is Xpert Omni MTB/RIF Ultra used for?

Laboratory use

What are the hazard statements for Xpert Omni MTB/RIF Ultra?

This substance has 6 hazard statements: H226: Flammable liquid and vapour H314: Causes severe skin burns and eye damage. H318: Causes serious eye damage Suspected of causing genetic defects. Suspected of damaging fertility or the unborn child. May cause damage to organs through prolonged or repeated exposure.

What is the melting point of Xpert Omni MTB/RIF Ultra?

The melting point is Data lacking and the boiling point is Data lacking.