NextSDS Logo
Safety Data Sheet EN

HiTEC® 12320 Performance Additive

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HiTEC® 12320 Performance Additive
Product Form
Liquid.

Regulatory Identifiers

CAS Number
N/A
UFI Code
PYRJ-562V-9871-2CYD

Identified Uses

Formulation of additive packages, lubricants and greases - Industrial General use of lubricants and greases in vehicles or machinery - Industrial General use of lubricants and greases in vehicles or machinery - Professional

Manufacturers & Suppliers

A

Afton Chemical Limited

manufacturer

Euro-Tech Centre London Road, Bracknell, RG12 2UW, England

+44 1344 304141

A

Afton Chemical S.R.L. (Woluwe)

national supplier

Alma Court, Lenneke Marelaan, 8 B-1932 St-Stevens-Woluwe Belgium

+32 2 715 2211

A

Afton Chemical S.R.L. (Feluy Plant)

national supplier

Rue de Scoufflény, 50 B-7191 Ecaussinnes Lalaing, Belgium

+32 67 286211

Emergency Contacts

Austria

+43-13649237

24 hours a day, 7 days a week

Portugal

+351-308801773

24 hours a day, 7 days a week

Belgium

+32-28083237

24 hours a day, 7 days a week

Slovakia

+421-233057972

24 hours a day, 7 days a week

Bulgaria

+359-32570104

24 hours a day, 7 days a week

Slovenia

+38-618888016

24 hours a day, 7 days a week

Croatia

+385-17776920

24 hours a day, 7 days a week

Swedish

+46-852503403

24 hours a day, 7 days a week

Czech Republic

+420-228880039

24 hours a day, 7 days a week

Switzerland

+41-435082011

24 hours a day, 7 days a week

Denmark

+45-69918573

24 hours a day, 7 days a week

Ukraine

+380-947101374

24 hours a day, 7 days a week

Finland

+358-942419014

24 hours a day, 7 days a week

UK

+44-8708200418

24 hours a day, 7 days a week

France

+33-975181407

24 hours a day, 7 days a week

International

+1-703-527-3887

24 hours a day, 7 days a week

Germany

+49-69-6435-08409

24 hours a day, 7 days a week

Asia Pacific

+65 3163 8374

24 hours a day, 7 days a week

Hungary

+36-18088425

24 hours a day, 7 days a week

Australia

+61-290372994

24 hours a day, 7 days a week

Ireland

+353-19014670

24 hours a day, 7 days a week

China

4001-204937

24 hours a day, 7 days a week

Italy

+39-0245557031

24 hours a day, 7 days a week

India

+(91)-22-3354 3594

24 hours a day, 7 days a week

Luxembourg

+352-20202416

24 hours a day, 7 days a week

Japan

+81-345209637

24 hours a day, 7 days a week

The Netherlands

+31-858880596

24 hours a day, 7 days a week

Singapore

+65-3158-1349

24 hours a day, 7 days a week

Norway

+47-21930678

24 hours a day, 7 days a week

South Korea

00-308-13-2549

24 hours a day, 7 days a week

Poland

+48-223988029

24 hours a day, 7 days a week

Spanish language

+1-703-741-5979

24 hours a day, 7 days a week

ES

US & Canada

1-800-424-9300

24 hours a day, 7 days a week

Austria Poison Centre

+43 1 406 43 43

Belgium Poison Centre

+32 (0)70 245 245

Bulgaria Poison Centre

+359 2 9154 233

Croatia Poison Centre

+3851 2348 342

Cyprus Poison Centre

+357 1401

Czechia Poison Centre

+420 224 91 92 93

Denmark Poison Centre

+45 8212 1212

Estonia Poison Centre

+372 16662

France Poison Centre

+33 (0)1 45 42 59 59

Greece Poison Centre

+30 210 779 3777

Latvia Poison Centre

+371 67042473

Lithuania Poison Centre

+370 (85) 236 2052

Luxembourg Poison Centre

+352 8002 5500

Netherlands Poison Centre

+31 (0)88 755 8000

Norway Poison Centre

+47 22 59 13 00

Portugal Poison Centre

+351 800 250 250

Romania Poison Centre

+40 (0)21 318 36 06

8am – 3pm

Slovakia Poison Centre

+421 2 5477 4166

Slovenia Poison Centre

+386 112

Hungary Poison Centre

+36 80 201 199

Iceland Poison Centre

+354 112

Italy Poison Centre (Bergamo)

+39 800 883 300

Italy Poison Centre (Florence)

+39 055 794 7819

Italy Poison Centre (Foggia)

+39 800 183 459

Italy Poison Centre (Milan)

+39 02 6610 1029

Italy Poison Centre (Naples)

+39 081 545 3333

Italy Poison Centre (Pavia)

+39 0382 24444

Italy Poison Centre (Rome)

+39 06 305 4343

Italy Poison Centre (Rome)

+39 06 4997 8000

Italy Poison Centre (Rome)

+39 06 6859 3726

Italy Poison Centre (Verona)

+39 800 011 858

Spain Poison Centre

+34 91 562 04 20

Sweden Poison Centre

+46 112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Chronic Cat. 3 H412

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

Avoid release to the environment.
Store in a well-ventilated place.
Dispose of contents and container in accordance with all local, regional, national and international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Afton HiTEC® 12320 Performance Additive. The mineral oils in the product contain < 3% DMSO extract (IP 346).

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 64742-65-0 10 - 15% Yes
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 10 - 15% No
N/A --- 5 - 10% Yes
Distillates (petroleum), solvent-refined heavy paraffinic EC: 265-090-8 64741-88-4 5 - 10% No
Phenol, dodecyl-, sulfurized, carbonates, calcium salts, overbased EC: 701-251-5 122384-87-6 5 - 10% Yes
Phosphorodithioic acid, mixed O,O-bis (1,3-dimethylbutyl and iso-Pr) esters, zinc salts EC: 283-392-8 84605-29-8 1 - 3% Yes
Phosphorodithioic acid, mixed O,O-bis(2-ethylhexyl and iso-Bu and iso-Pr) esters, zinc salts EC: 288-917-4 85940-28-9 1 - 3% Yes
phenol, (tetrapropenyl) derivatives EC: 616-100-8 74499-35-7 0.1 - 0.3% Yes
Alcohols, C12-14, ethoxylated EC: 500-213-3 68551-12-2 0.1 - 0.3% Yes

[1] Substance classified with a physical, health or environmental hazard [2] Substance with a workplace exposure limit [3] Substance of equivalent concern

Notes

See Section 16 for the full text of the H statements declared above. There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs or vPvBs or have been assigned a workplace exposure limit and hence require reporting in this section. If REACH registration numbers do not appear the substance is either exempt from registration, does not meet the minimum volume threshold for registration, the registration date has not yet come due or this information is proprietary. If a dash (-) is shown in the CAS number field, please contact an Afton representative for information about the CAS and other chemical identity numbers used for global regulatory compliance. The EC substance definition and related classification & labelling have been developed in the framework of the regulation (EC) No. 1907/2006 (REACH). The related CAS number (*) is used for the purposes of the international inventories present in Section 15 of the SDS. Please note some GHS hazard classifications listed above may not be applicable in your country or region and are shown for informational purposes only. Occupational exposure limits, if available, are listed in Section 8.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.

Symptoms: No known significant effects or critical hazards.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: No known significant effects or critical hazards.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards.

Ingestion

Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No known significant effects or critical hazards.

Immediate Medical Attention

Get medical attention if irritation occurs (eye), if adverse health effects persist or are severe (inhalation, ingestion), or if symptoms occur (skin). If unconscious, place in recovery position and get medical attention immediately. In case of inhalation of decomposition products in a fire, symptoms may be delayed, and the exposed person may need to be kept under medical surveillance for 48 hours.

Medical Treatment

No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water spray (fog), foam, dry chemical or CO₂.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst. This material is harmful to aquatic life with long lasting effects.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment. If specialized clothing is required to deal with the spillage, take note of any information in Section 8 on suitable and unsuitable materials. See also the information in "For non-emergency personnel".

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). Water polluting material. May be harmful to the environment if released in large quantities.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.

Materials: water, inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapor or mist. Avoid release to the environment. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective threshold limit value.

Hands

Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Softening Point
---
Relative Density
Not available.
Odor
Not available.
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Evaporation Rate
Not available.
Ph
Not available.
Crystallisation Point
---
State Under Standard Conditions
---
Appearance
---
Vapor Density
Not available.
Boiling Point
Not available.
Kinematic Viscosity
Kinematic (40°C): 2710 mm²/s (2710 cSt) 127 cSt at 100°C
Vapor Pressure
Not available.
Odor Threshold
Not available.
Physical State Data
liquid
Solubility
Not available.
Flash Point
135°C
Flammability
Not applicable (liquid).
Cloud Point
---
Colour
Not available.
Freezing Point
Not available.
Decomposition Temperature
Not available.
Form
---
Partition Coefficient
Not applicable.
Molecular Weight
---
Relative Evaporation Rate
---
Solubility In Water
---
Explosive Limits
---
Solidification Point
---
Physical State
Liquid.
Density
0.954 g/cm³
Solubility In Fat
---
Upper Explosive Limit
Not available.
Bulk Density
---
Melting Point
Not available.
Lower Explosive Limit
Not available.
Auto Ignition Temperature
Not available.
Properties Status
---
Colour Intensity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

High temperatures, sparks and open flames.

Incompatible

Strong oxidizing and reducing agents.

Decomposition

Hydrogen sulfide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HiTEC® 12320 Performance Additive?

The signal word is no signal word.

What is the physical form of HiTEC® 12320 Performance Additive?

HiTEC® 12320 Performance Additive is a liquid. with not available. color. It has not available. odor.

What is the solubility of HiTEC® 12320 Performance Additive?

Not available.

What is HiTEC® 12320 Performance Additive used for?

Formulation of additive packages, lubricants and greases - Industrial General use of lubricants and greases in vehicles or machinery - Industrial General use of lubricants and greases in vehicles or machinery - Professional

What are the hazard statements for HiTEC® 12320 Performance Additive?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of HiTEC® 12320 Performance Additive?

The melting point is Not available. and the boiling point is Not available..

Compliance Scanner