Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TEFROLITH® FTG-35 Additive Emulsion
- Product Code
- 02082000100000X
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
G. Theodor Freese GmbH
Carl-Benz-Straße 29 28237 Bremen Germany
0421-39608100
www.gtf-freese.de
Emergency Contacts
Emergency Contact
+49 421 39608-0
24 hr.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1,2-benzisothiazol-3(2H)-one; 1,2-benzisothiazolin-3-one EC: 220-120-9 | 2634-33-5 | 0.005% | Yes |
Notes
Full text of H- and EUH-statements: see section 16. Full text of H-phrases: see section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest. In case of irregular breathing or respiratory arrest provide artificial respiration.
Remove contaminated, saturated clothing immediately. After contact with skin, wash immediately with plenty of water and soap.
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Seek medical advice immediately.
If swallowed, rinse mouth with water (only if the person is conscious). Seek medical advice immediately. Keep victim calm. Do NOT induce vomiting.
Immediate Medical Attention
First Aid, decontamination, treatment of symptoms.
Medical Treatment
First Aid, decontamination, treatment of symptoms.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
alcohol resistant foam, Carbon dioxide (CO2), Powder, spray mist, (water)
Do not allow water used to extinguish fire to enter drains, ground or waterways.
Provide a conveniently located respiratory protective device. Do not allow water used to extinguish fire to enter drains, ground or waterways.
Firefighter Protection
Provide a conveniently located respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter into surface water or drains. If the product contaminates lakes, rivers or sewages, inform competent authorities in accordance with local regulations.
Fouled surfaces must be immediately cleaned with suitable solvents.
Materials: suitable solvents
Related Products
Similar products with comparable safety profiles
Interflon Finnoly Additive T251
---
Interflon Finnoly Additive T251
---
HiTEC® 339 Performance Additive
UFI: GUX9-Q8KS-P750-D94Q
FERROCOTE™ 5856 BF T1
---
HiTEC® 55325 Performance Additive
UFI: EEPP-60E4-500S-M9J4
Eastman TXIB(TM) Formulation Additive
---
HiTEC 34022 Performance Additive
UFI: 1D6P-MOMN-K005-UJJU
HiTEC® 11500 Performance Additive
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin, eyes and clothes. Personal protection equipment: see section 8 Always keep in containers that correspond to the material of the original container. Follow the legal protection and safety regulations. Do not inhale vapours or mist.
Storage in accordance with the Ordinance on Industrial Safety and Health (BetrSiVO). Keep container tightly closed. Store carefully closed containers upright to prevent any leaks. Protect from frost and exposure to sun. Store in a dry place. Store in a closed container.
When using do not eat, drink or smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide good ventilation. This can be achieved with local or room suction.
NBR (Nitrile rubber) For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. Observe the instructions and details for use, storage, maintenance and replacement provided by the protective glove manufacturer. Penetration time of glove material depending on intensity and duration of exposure to skin. Recommended glove articles: EN ISO 374
Eye glasses with side protection
Wear breathing apparatus if exposed to vapours/dusts/aerosols.
Wear suitable protective clothing. Barrier creams can help protecting exposed skin areas. In no case should they be used after contact. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.
Do not allow to enter into surface water or drains. If the product contaminates lakes, rivers or sewages, inform competent authorities in accordance with local regulations.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable when applying the recommended regulations for storage and handling.
No known hazardous reactions.
No known hazardous reactions.
Stable when applying the recommended regulations for storage and handling.
No data available
No known hazardous decomposition products,
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TEFROLITH® FTG-35 Additive Emulsion?
The signal word is no signal word.
What is the physical form of TEFROLITH® FTG-35 Additive Emulsion?
TEFROLITH® FTG-35 Additive Emulsion is a liquid with white color. It has characteristic odor.
What is the melting point of TEFROLITH® FTG-35 Additive Emulsion?
The melting point is 0 °C and the boiling point is 100 °C.