NextSDS Logo
Safety Data Sheet EN

Reducing Agent D p

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Reducing Agent D p
Product Code
101190

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industry sector : Textile processing industry Type of use : Textile auxiliary

Manufacturers & Suppliers

A

Archroma Management GmbH

manufacturer

Neuhofstrasse 11, 4153 Reinach, Switzerland

+41 61 716 3401

Emergency Contacts

Emergency Contact

+49 69 2222 5285

24 h

Emergency Contact

+33 1 7211 0003

24 h

Emergency Contact

+39 0236 042 884

24 h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Chemical characterization glucose derivative

Chemical Name CAS Number Concentration Hazardous
glucose derivative --- --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air.

Skin contact

In case of contact, immediately flush skin with plenty of water.

Eye contact

Rinse immediately with plenty of water for at least 15 minutes.

Ingestion

If swallowed, call a poison control centre or doctor immediately.

Immediate Medical Attention

If skin irritation occurs: Get medical advice/ attention. If swallowed, call a poison control centre or doctor immediately.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

all

Unsuitable media

No restrictions

Specific hazards

Carbon oxides

Firefighter Protection

Self-contained breathing apparatus, Full protective suit

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear suitable protective equipment. Ventilate the area.

Environmental

Collect contaminated fire extinguishing water separately. This must not be discharged into drains. The product should not be allowed to enter drains, water courses or the soil.

Cleanup methods

Wash with plenty of water.

Materials: Water

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures necessary.

Storage

Keep containers tightly closed in a cool, well-ventilated place. Do not freeze.

Hygiene

This substance is classified as non-hazardous. However the usual precautions for handling chemicals must be observed to avoid contact with the skin, eyes and respiratory tract. In case of contact with the product, wash the eye immediately with running water and the skin with water and soap.

Fire prevention

Potential dust explosion hazard.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Local ventilation recommended - mechanical ventilation may be used.

Hands

Protective gloves. Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).

Eyes

Safety glasses

Respiratory

in case of dust, use dust-mask.

Skin/Body

working clothes

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Freezing Point
---
Softening Point
---
Bulk Density
600 - 700 kg/m3
Odor Threshold
not available
Dynamic Viscosity
not available
Relative Density
not applicable
Appearance
---
Solubility In Fat
---
Relative Evaporation Rate
---
Solidification Point
---
Colour Intensity
---
Explosive Limits
---
State Under Standard Conditions
---
Decomposition Temperature
not available
Flammability
---
Ph
5 - 6 (20 °C, 50 g/l)
Form
powder
Physical State Data
solid
Voc Content
---
Crystallisation Point
---
Lower Explosive Limit
not available
Odor
---
Metal Corrosion
---
Cloud Point
---
Vapor Pressure
not available
Physical State
solid
Auto Ignition Temperature
not available
Solubility
---
Flash Point
not applicable
Partition Coefficient
not available
Colour
white
Density
not available
Solubility In Water
approximately 100 g/l (20 °C) soluble
Boiling Point
not applicable
Evaporation Rate
not available
Melting Point
approximately 146 °C
Kinematic Viscosity
not available
Upper Explosive Limit
not available
Vapor Density
not available
Properties Status
---
Molecular Weight
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

See section 10.3. "Possibility of hazardous reactions"

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

None known.

Incompatible

not known

Decomposition

When used and handled as intended, none.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Reducing Agent D p?

The signal word is no signal word.

What is the physical form of Reducing Agent D p?

Reducing Agent D p is a solid with white color.

What is Reducing Agent D p used for?

Industry sector : Textile processing industry Type of use : Textile auxiliary

What is the melting point of Reducing Agent D p?

The melting point is approximately 146 °C and the boiling point is not applicable.