NextSDS Logo
Safety Data Sheet EN

HiTEC® 1933X Performance Additive

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HiTEC® 1933X Performance Additive
Product Form
Liquid.

Regulatory Identifiers

CAS Number
N/A
UFI Code
7KJH-Y6QF-A75C-91F8

Identified Uses

Petrochemical industry: Lubricating Oil Additive.

Manufacturers & Suppliers

A

Afton Chemical Limited

manufacturer

Euro-Tech Centre London Road, Bracknell, RG12 2UW, England

+44 1344 304141

A

Afton Chemical S.R.L. (Woluwe)

manufacturer

Alma Court, Lenneke Marelaan, 8 B-1932 St-Stevens-Woluwe Belgium

+32 2 715 2211

A

Afton Chemical S.R.L. (Feluy Plant)

manufacturer

Rue de Scoufflény, 50 B-7191 Ecaussinnes Lalaing, Belgium

+32 67 286211

Emergency Contacts

Emergency Contact

+43-13649237

24 hours a day, 7 days a week

Emergency Contact

+32-28083237

24 hours a day, 7 days a week

Emergency Contact

+359-32570104

24 hours a day, 7 days a week

Emergency Contact

+385-17776920

24 hours a day, 7 days a week

Emergency Contact

+420-228880039

24 hours a day, 7 days a week

Emergency Contact

+45-69918573

24 hours a day, 7 days a week

Emergency Contact

+358-942419014

24 hours a day, 7 days a week

Emergency Contact

+33-975181407

24 hours a day, 7 days a week

Emergency Contact

+49-69-6435-08409

24 hours a day, 7 days a week

Emergency Contact

+36-18088425

24 hours a day, 7 days a week

Emergency Contact

+353-19014670

24 hours a day, 7 days a week

Emergency Contact

+39-0245557031

24 hours a day, 7 days a week

Emergency Contact

+352-20202416

24 hours a day, 7 days a week

Emergency Contact

+31-858880596

24 hours a day, 7 days a week

Emergency Contact

+47-21930678

24 hours a day, 7 days a week

Emergency Contact

+48-223988029

24 hours a day, 7 days a week

Emergency Contact

+351-308801773

24 hours a day, 7 days a week

Emergency Contact

+421-233057972

24 hours a day, 7 days a week

Emergency Contact

+38-618888016

24 hours a day, 7 days a week

Emergency Contact

+46-852503403

24 hours a day, 7 days a week

Emergency Contact

+41-435082011

24 hours a day, 7 days a week

Emergency Contact

+380-947101374

24 hours a day, 7 days a week

Emergency Contact

+44-8708200418

24 hours a day, 7 days a week

Emergency Contact

+1-703-527-3887

24 hours a day, 7 days a week

Emergency Contact

+65 3163 8374

24 hours a day, 7 days a week

Emergency Contact

+61-290372994

24 hours a day, 7 days a week

Emergency Contact

4001-204937

24 hours a day, 7 days a week

Emergency Contact

+(91)-22-3354 3594

24 hours a day, 7 days a week

Emergency Contact

+81-345209637

24 hours a day, 7 days a week

Emergency Contact

+65-3158-1349

24 hours a day, 7 days a week

Emergency Contact

00-308-13-2549

24 hours a day, 7 days a week

Emergency Contact

+1-703-741-5979

24 hours a day, 7 days a week

Emergency Contact

1-800-424-9300

24 hours a day, 7 days a week

Emergency Contact

+43 1 406 43 43

Emergency Contact

+32 (0)70 245 245

Emergency Contact

+359 2 9154 233

Emergency Contact

+3851 2348 342

Emergency Contact

+357 1401

Emergency Contact

+420 224 91 92 93

Emergency Contact

+45 8212 1212

Emergency Contact

+372 16662

Emergency Contact

+33 (0)1 45 42 59 59

Emergency Contact

+30 210 779 3777

Emergency Contact

+36 80 201 199

Emergency Contact

+354 112

Emergency Contact

+39 800 883 300

Emergency Contact

+39 055 794 7819

Emergency Contact

+39 800 183 459

Emergency Contact

+39 02 6610 1029

Emergency Contact

+39 081 545 3333

Emergency Contact

+39 0382 24444

Emergency Contact

+39 06 305 4343

Emergency Contact

+39 06 4997 8000

Emergency Contact

+39 06 6859 3726

Emergency Contact

+39 800 011 858

Emergency Contact

+371 67042473

Emergency Contact

+370 (85) 236 2052

Emergency Contact

+352 8002 5500

Emergency Contact

+31 (0)88 755 8000

Emergency Contact

+47 22 59 13 00

Emergency Contact

+351 800 250 250

Emergency Contact

+40 (0)21 318 36 06

8am – 3pm

Emergency Contact

+421 2 5477 4166

Emergency Contact

+386 112

Emergency Contact

+34 91 562 04 20

Emergency Contact

+46 112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

No known significant effects or critical hazards.

Precautionary Statements

P403 Store in a well-ventilated place.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 64742-65-0 15 - 25% Yes
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 15 - 25% No
Distillates (petroleum), solvent-refined heavy paraffinic EC: 265-090-8 64741-88-4 5 - 10% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.

Symptoms: No known significant effects or critical hazards. No specific data.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes.

Symptoms: No known significant effects or critical hazards. No specific data.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses.

Symptoms: No known significant effects or critical hazards. No specific data.

Ingestion

Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel.

Symptoms: No known significant effects or critical hazards. No specific data.

Immediate Medical Attention

Get medical attention if irritation occurs (eye). Get medical attention if symptoms occur (inhalation, skin, ingestion).

Medical Treatment

No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water spray (fog), foam, dry chemical or CO₂.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant.

Materials: sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective threshold limit value.

Hands

Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Brown
Colour Intensity
Dark
Form
---
Odor
Not available.
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
Closed cup: 150°C [Pensky-Martens Minimum]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
Not available.
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
Not available.
Relative Density
0.925
Bulk Density
---
Density
0.925 g/cm³ [15.6°C]
Flammability
Not applicable (liquid).
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Not available.
Partition Coefficient
Not applicable.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
600 cSt @ 100°C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

High temperatures, sparks and open flames.

Incompatible

Strong oxidizing and reducing agents.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.4 Mobility in soil

Soil/water partition : Not available. coefficient (Koc) Mobility : Not available.

12.5 Results of PBT and vPvB assessment

This mixture does not contain any substances that are assessed to be a PBT or a vPvB.

The mixture does not contain any substances that are assessed to be a PBT or a vPvB.

12.6 Endocrine disrupting properties

Based on available data, the classification criteria are not met.

Based on available data, the classification criteria are not met.

12.7 Other adverse effects

No known significant effects or critical hazards.

No known significant effects or critical hazards.

12.1 Toxicity

| Product/ingredient name | Result | Species | Exposure | Remarks | | --- | --- | --- | --- | --- | | Distillates (petroleum), solvent-dewaxed heavy paraffinic | Acute EL50 >10000 mg/l | Daphnia - Daphnia magna | 48 hours | Based on data for a similar substance. | | | Acute LL50 >100 mg/l | Fish - Pimephales promelas | 96 hours | Based on data for a similar substance. | | | Chronic NOEL ≥100 mg/l | Algae - Pseudokirchneriella subcapitata | 72 hours | Based on data for a similar substance. | | | Chronic NOEL 10 mg/l | Daphnia - Daphnia magna | 21 days | Based on data for a similar substance. | | | Chronic NOEL 1000 mg/l | Fish - Oncorhynchus mykiss | 14 days | QSAR result. |

12.1 Toxicity

| Product/ingredient name | Result | Species | Exposure | Remarks | | --- | --- | --- | --- | --- | | Distillates (petroleum), hydrotreated heavy paraffinic | Acute EL50 >10000 mg/l | Daphnia - Daphnia magna | 48 hours | Based on data for a similar substance. | | | Acute LL50 >100 mg/l | Fish - Pimephales promelas | 96 hours | Based on data for a similar substance. | | | Chronic NOEL ≥100 mg/l | Algae - Pseudokirchneriella subcapitata | 72 hours | Based on data for a similar substance. | | | Chronic NOEL 10 mg/l | Daphnia - Daphnia magna | 21 days | Based on data for a similar substance. | | | Chronic NOEL 1000 mg/l | Fish - Oncorhynchus mykiss | 14 days | QSAR result. |

12.1 Toxicity

| Product/ingredient name | Result | Species | Exposure | Remarks | | --- | --- | --- | --- | --- | | Distillates (petroleum), solvent-refined heavy paraffinic | Acute EL50 >10000 mg/l | Daphnia - Daphnia magna | 48 hours | Based on data for a similar substance. | | | Acute LL50 >100 mg/l | Fish - Pimephales promelas | 96 hours | Based on data for a similar substance. | | | Chronic NOEL ≥100 mg/l | Algae - Pseudokirchneriella subcapitata | 72 hours | Based on data for a similar substance. | | | Chronic NOEL 10 mg/l | Daphnia - Daphnia magna | 21 days | Based on data for a similar substance. | | | Chronic NOEL 1000 mg/l | Fish - Oncorhynchus mykiss | 14 days | QSAR result. |

12.2 Persistence and degradability

| Product/ingredient name | Test | Result | Remarks | | --- | --- | --- | --- |

12.2 Persistence and degradability

| Product/ingredient name | Test | Result | Remarks | | --- | --- | --- | --- | | Distillates (petroleum), solvent-dewaxed heavy paraffinic | OECD 301F Ready Biodegradability - Manometric | 31 % - Not readily - 28 days | Based on data for a similar substance. |

12.2 Persistence and degradability

| Product/ingredient name | Test | Result | Remarks | | --- | --- | --- | --- | | Distillates (petroleum), hydrotreated heavy paraffinic | OEC D 301F Ready Biodegradability - Manometric | 31 % - Not readily - 28 days | Based on data for a similar substance. |

12.2 Persistence and degradability

Product/ingredient name: Distillates (petroleum), solvent-refined heavy paraffinic | Test: OEC D 301F Ready Biodegradability - Manometric | Result: 31 % - Not readily - 28 days | Remarks: Based on data for a similar substance.

12.3 Bioaccumulative potential

Conclusion/Summary : Not available. | Product/ingredient name | LogPow | BCF | Potential | | --- | --- | --- | --- |

12.3 Bioaccumulative potential

| Product/ingredient name | LogPow | BCF | Potential | | --- | --- | --- | --- | | Distillates (petroleum), solvent-refined heavy paraffinic | 3.9 to 6 | - | high |
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

13 02 05* mineral-based non-chlorinated engine, gear and lubricating oils EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3257
Shipping Name
Elevated temperature liquid, n.o.s. (Petroleum distillates; Polyolefin amide alkyleneamine)
Transport Class
9
Packing Group
III
ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU) 2020/878 and United Kingdom

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HiTEC® 1933X Performance Additive?

The signal word is no signal word.

What is the physical form of HiTEC® 1933X Performance Additive?

HiTEC® 1933X Performance Additive is a liquid with brown color. It has not available. odor.

What is the solubility of HiTEC® 1933X Performance Additive?

Not available.

What is HiTEC® 1933X Performance Additive used for?

Petrochemical industry: Lubricating Oil Additive.

What are the hazard statements for HiTEC® 1933X Performance Additive?

This substance has 1 hazard statement:

  • No known significant effects or critical hazards.

What is the melting point of HiTEC® 1933X Performance Additive?

The melting point is Not available. and the boiling point is Not available..