NextSDS Logo
Safety Data Sheet NL

Stuc-Primer

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Stuc-Primer

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Primer

Uses advised against

Geen relevante informatie beschikbaar.

Manufacturers & Suppliers

K

Knauf S.C.S.

manufacturer

Rue du Parc Industriel, 1, B-4480 Engis

+32 (0)4 273.83.11

K

Knauf Technical Competence Center

+32 (0)4 273.83.02

Emergency Contacts

Europees noodnummer

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Precautionary Statements

P102 Buiten bereik van kinderen houden.
P262 Contact met de ogen, huid of kleren vermijden.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Chemische karakterisering: Mengsels

Notes

Gevaarlijke stoffen: Niet van toepassing

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

De persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen. Bij onwel voelen een arts raadplegen.

Skin contact

De huid afspoelen en vervolgens wassen met overvloedig water en zeep. Gebruik geen oplos- of verdunningsmiddelen.

Eye contact

Onmiddellijk en overvloedig spoelen met water. Contactlenzen verwijderen, indien mogelijk. Blijven spoelen. Bij aanhoudende oogirritatie: een arts raadplegen.

Ingestion

De mond spoelen en overvloedig water nadrinken. Arts raadeplegen voor een medische behandeling.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Verneveld water. Schuim. Droog poeder. Koolstofdioxide.

Unsuitable media

Sterke waterstraal.

Specific hazards

Geen bijkomende relevante informatie beschikbaar.

Firefighter Protection

Onafhankelijk werkend ademhalingsapparaat. Volledig beschermende kleding.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Voorkom lozing in het milieu.

Cleanup methods

Met vloeistofbindend materiaal opnemen.

Materials: zand, diatomeeënaarde, zuurbinder of universele binder

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Contact met de huid en de ogen vermijden. Geen gas/rook/damp/aerosol inademen.

Storage

Uitsluitend in de oorspronkelijke verpakking bewaren. Vorstvrij opslaan. Tegen zonlicht beschermen. Op een goed geventileerde plaats bewaren.

Hygiene

Niet eten, drinken of roken tijdens het gebruik van dit product. Verwijderd houden van etens- en drinkwaren, inclusief dierenvoer. Verontreinigde kleding wassen alvorens deze opnieuw te gebruiken. Handen wassen voor pauzes en na het werk.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Beschermende handschoenen. Nitrilrubber (NBR), butylrubber.

Eyes

Veiligheidsbril met zijdelingse bescherming

Respiratory

Niet noodzakelijk.

Skin/Body

Beschermende werkkledij.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
Niet bepaald
Ph
7 – 9 bij 20 °C
Flammability
Niet bepaald
Odor
Zwak
Properties Status
---
Molecular Weight
---
Relative Evaporation Rate
---
Metal Corrosion
---
Freezing Point
---
Colour Intensity
---
Bulk Density
---
Crystallisation Point
---
Appearance
Vloeibaar
Voc Content
≤ 0,1 % (≤ 1 g/l)
Melting Point
0 °C
Solidification Point
---
Explosive Limits
---
Solubility In Fat
---
Vapor Density
Niet bepaald
Density
Niet bepaald
Form
Vloeibaar
Evaporation Rate
Niet bepaald
State Under Standard Conditions
---
Upper Explosive Limit
---
Relative Density
0,98 – 1,02
Decomposition Temperature
Niet bepaald
Cloud Point
---
Physical State Data
liquid
Lower Explosive Limit
---
Softening Point
---
Solubility In Water
Oplosbaar
Dynamic Viscosity
2500 – 3500 mPa*s
Odor Threshold
Niet bepaald
Flash Point
Niet bepaald
Boiling Point
100 °C
Auto Ignition Temperature
Het product is niet zelfontvlambaar
Kinematic Viscosity
---
Physical State
Vloeibaar
Colour
Geel
Solubility
---
Partition Coefficient
Niet bepaald
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabiel onder normale gebruiksomstandigheden.

Reactivity

Het product is onder normale gebruiks-, opslag- en transportcondities niet reactief.

Hazardous reactions

Geen gevaarlijke reacties bekend.

Avoid

Geen aanvullende informatie beschikbaar.

Incompatible

Geen aanvullende informatie beschikbaar

Decomposition

Onder normale opslag- en gebruiksvoorwaarden zullen er geen gevaarlijke ontledingsproducten ontstaan.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Afvalverwijdering conform de wettelijke bepalingen.

Disposal

Afvalverwijdering conform de wettelijke bepalingen.

Waste Codes

08 01 20 waterige oplossing die verf of lak bevat anders dan die vernoemd in 08 01 19 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Geen
Shipping Name
Geen
Transport Class
Geen
Packing Group
Geen
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Bevat geen enkele stof die in Bijlage XIV van REACH staat vermeld

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Stuc-Primer?

The signal word is no signal word.

What is the physical form of Stuc-Primer?

Stuc-Primer is a vloeibaar appearing as vloeibaar with geel color. It has zwak odor.

What is Stuc-Primer used for?

Primer

What is the melting point of Stuc-Primer?

The melting point is 0 °C and the boiling point is 100 °C.