NextSDS Logo
AL

ALUMINUM WELDING WIRE AND METALLIZING WIRE

NO SIGNAL WORD Solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ALUMINUM WELDING WIRE AND METALLIZING WIRE

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Welding, Filler Metal, Metallizing, Brazing

Overview

ALUMINUM WELDING WIRE AND METALLIZING WIRE is a solid substance commonly used welding, filler metal, metallizing, brazing.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Flam. Sol. Category 1
Water-react. Category 1
Self-heat Category 1
Eye Irrit. Category 2
Skin Irr. Category 2
Skin Sens. Category 1
Resp. Sens. Category 1
Skin Corr./Eye Dam. Category 1B
Carc. Category 1A
Carc. Category 2
Repr. Category 1A
Repr. Category 2
Muta. Category 2
STOT SE Category 1
STOT SE Category 3
STOT RE Category 1
STOT RE Category 2

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

AlcoTec Wire Corporation

manufacturer

๐Ÿ“

2750 Aero Park Drive, Traverse City, MI 49686-9263 USA

๐ŸŒ

US

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Aluminum alloys containing various elements (Si, Fe, Cu, Mn, Mg, Cr, Ni, Zn, Ti, others) in specified ranges or maximums by weight percent. Aluminum is typically the remainder or minimum.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Titanium N/A 0.002-0.3% โœ“ Non-hazardous
Aluminum N/A 99-99.99% โœ“ Non-hazardous
Silicon N/A 0.006-13% โœ“ Non-hazardous
Iron N/A 0.006-0.8% โœ“ Non-hazardous
Copper N/A 0.005-6.8% โœ“ Non-hazardous
Manganese N/A 0.002-1% โœ“ Non-hazardous
Magnesium N/A 0.01-5.5% โœ“ Non-hazardous
Chromium N/A 0.01-0.35% โœ“ Non-hazardous
Nickel N/A 0.05% โœ“ Non-hazardous
Zinc N/A 0.03-0.25% โœ“ Non-hazardous
Beryllium N/A 0.0003% โœ“ Non-hazardous
Gallium N/A 0.03% โœ“ Non-hazardous
Boron N/A 0.05% โœ“ Non-hazardous
Vanadium N/A 0.15% โœ“ Non-hazardous
Zirconium N/A 0.1-0.25% โœ“ Non-hazardous
Tin N/A 0.05% โœ“ Non-hazardous

Additional Information

See notes for additional minor constituents and maximum allowable concentrations for trace elements.

Composition Notes

Alloy ingredients are listed as percent by weight (maximum or range), except for Aluminum, which is a minimum percent by weight. Rmnd = remainder. See notes for trace elements.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. Check for clear airway, breathing, and presence of pulse. Provide CPR for persons without pulse or respirations. Consult a physician immediately.

๐Ÿ–๏ธ Skin Contact

Wash thoroughly with soap and water. Consult a physician if irritation persists.

๐Ÿ‘๏ธ Eye Contact

Flush eyes with plenty of water or saline for at least 15 minutes. Consult a physician.

๐Ÿšจ Immediate Medical Attention Required

Consult a physician immediately for inhalation exposure. Consult a physician for eye contact. Consult a physician if skin irritation persists.

Medical Treatment

Provide CPR for persons without pulse or respirations.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Solid
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Solid
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not applicable
๐Ÿงช Ph
Not applicable
๐ŸงŠ Melting Point
970 -1215 F (521 -657 C)
Critical Property
๐Ÿ’จ Boiling Point
Not applicable
Critical Property
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
970 -1215 F (521 -657 C)
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not applicable
๐Ÿ“Š Vapor Density
Not applicable
๐Ÿ“Š Relative Density
Not determined
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Approximately 0.1 lb/in3
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not applicable
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use with adequate explosion-proof ventilation. Welding or cutting operations involving beryllium-containing base or filler metals shall be done using local exhaust ventilation.

๐Ÿงค Hand Protection

Wear impervious gloves to avoid any skin injury.

๐Ÿ‘๏ธ Eye Protection

Welders should use appropriate equipment (e.g. welder's helmet, face shield, filter lens) to prevent eye irritation or flash burns.

๐Ÿ˜ท Respiratory Protection

Use NIOSH-approved respiratory protection [dust, fume, high efficiency dust/fume mask for lead, or other (organic vapor)] as specified by an Industrial Hygienist or other qualified professional if concentrations exceed the limits. Welding or cutting operations involving beryllium-containing base or filler metals shall be done using airline respirators unless atmospheric tests under the most adverse conditions have established that the workers' exposures is within the acceptable concentrations defined by 29 CFR 1910.1000. In all cases, workers in the immediate vicinity of the welding or cutting operations shall be protected as necessary by local exhaust ventilation or airline respirators.

๐Ÿฆบ Skin/Body Protection

Wear impervious gloves to avoid any skin injury. Adequate protective clothing should be provided to prevent contamination of personal clothing where employees are exposed to beryllium above the PEL or where excessive contamination of clothing with beryllium is possible.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ALUMINUM WELDING WIRE AND METALLIZING WIRE?

The signal word for this substance is "no signal word".

What is the physical form of ALUMINUM WELDING WIRE AND METALLIZING WIRE?

ALUMINUM WELDING WIRE AND METALLIZING WIRE is a solid appearing as solid .

What is ALUMINUM WELDING WIRE AND METALLIZING WIRE used for?

Welding, Filler Metal, Metallizing, Brazing

What is the melting point of ALUMINUM WELDING WIRE AND METALLIZING WIRE?

The melting point is 970 -1215 F (521 -657 C) and the boiling point is Not applicable.