Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AQUALON® CELLULOSE GUM (CMC PURIFIED)
- Chemical Name
- sodium carboxymethylcellulose; cellulose, carboxymethyl ether, sodium salt
Regulatory Identifiers
- CAS Number
- 9004-32-4 Check regulations →
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Notes
This product is considered hazardous according to the OSHA Hazard Communication Standard 29CFR1910.1200 due to flammable dust potential. Hercules Incorporated has not determined the safety of this product for parenteral or medical implant uses.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Get medical attention if nasal, throat or lung irritation develops.
Symptoms: nasal, throat or lung irritation
Wash thoroughly with soap and water. Get medical attention if irritation develops or persists.
Symptoms: irritation
Remove contact lenses. Hold eyelids apart. Immediately flush eyes with plenty of low-pressure water for at least 15 minutes. Get medical attention if irritation persists.
No adverse health effects are expected from accidental ingestion of small amounts of this product. For ingestion of large amounts: If conscious, drink one to two glasses of water (8-16 oz.). Do not induce vomiting. Get immediate medical attention. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Get immediate medical attention (for ingestion of large amounts).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, dry chemical, foam, carbon dioxide or clean extinguishing agents may be used on fires involving this product.
Wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH approved (or equivalent) and full protective gear when fighting fires involving this product.
Firefighter Protection
Wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH approved (or equivalent) and full protective gear when fighting fires involving this product.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ventilate area. Clean up spills immediately. If product is contaminated, scoop into containers, and dispose appropriately. If product is not contaminated, scoop into clean containers for use. In case of accidental spill or release, refer to Section 8, Personal Protective Equipment and General Hygiene Practices.
Clean up spills immediately. If product is contaminated, scoop into containers, and dispose appropriately. If product is not contaminated, scoop into clean containers for use.
Materials: containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ground operator and pour material slowly into conductive, grounded chute. Keep container closed when not in use. Avoid emptying package in or near flammable vapors; static charges may cause flash fire.
Store in a cool, dry, well ventilated area.
Ground all equipment. Keep away from heat, flame, sparks and other ignition sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation.
Impervious gloves
Safety glasses
If upper respiratory tract irritation occurs, use an approved dust/mist respirator to minimize exposure. Wear approved dust/mist respirator if user operations create dust/mist that causes irritation.
Appropriate protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended handling and storage conditions.
Not anticipated under normal or recommended handling and storage conditions.
None known
None known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Landfilling in a permitted solid or hazardous waste facility is recommended.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AQUALON® CELLULOSE GUM (CMC PURIFIED)?
The signal word is warning.
What is the physical form of AQUALON® CELLULOSE GUM (CMC PURIFIED)?
AQUALON® CELLULOSE GUM (CMC PURIFIED) is a granular powder with white to off-white color. It has odorless odor.
What are the hazard statements for AQUALON® CELLULOSE GUM (CMC PURIFIED)?
This substance has 8 hazard statements:
- EUH014: May form flammable dust-air mixtures.
- EUH208: Static charges generated by emptying package in or near flammable vapors may cause flash fire.
- H317: Repeated ingestion may cause an allergic reaction in susceptible individuals.
- H317: Repeated or prolonged skin contact may cause allergic dermatitis in susceptible individuals.
- H319: May cause mild eye irritation.
- H335: Inhalation of dust may cause respiratory tract irritation.
- May cause skin irritation by mechanical abrasion.
- Surfaces subject to spills may become slippery.