Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Atellica™ CH Conditioner
Product Code
11099302

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Diagnostic agents.

Uses advised against

For professional users only.

Manufacturers & Suppliers

S

Siemens Healthcare Diagnostics Limited

manufacturer

Park View, Watchmoor Park, Camberley, Surrey, GU15 3YL, United Kingdom

+44 (0) 345 600 1955

Emergency Contacts

NHS Direct

0845 4647

NHS Direct

111

NHS 24

08454 24 24 24

Poison Control (Republic of Ireland)

01 809 2166

CHEMTREC

0870-8200418

CHEMTREC

+(353)-19014670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Eye Dam. Cat. 1 H318

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H318 Causes serious eye damage.

Precautionary Statements

P280 Wear protective gloves/protective clothing/eye protection/face protection.
P305 IF IN EYES:
P310 Immediately call a POISON CENTER or physician.
P338 Remove contact lenses, if present and easy to do. Continue rinsing.
P351 Rinse cautiously with water for several minutes.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture
Chemical Name CAS Number Concentration Hazardous
citric acid EC: 201-069-1 77-92-9 10% Yes
Alcohols, C11-15-secondary, ethoxylated 68131-40-8 5% Yes

Notes

See Section 16 for the full text of the H statements declared above. Occupational exposure limits, if available, are listed in Section 8.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Get medical attention immediately. Call a poison center or physician. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No specific data.

Skin contact

Get medical attention immediately. Call a poison center or physician. Wash contaminated skin with soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Chemical burns must be treated promptly by a physician. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: Adverse symptoms may include the following: pain or irritation redness blistering may occur

Eye contact

Get medical attention immediately. Call a poison center or physician. Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Chemical burns must be treated promptly by a physician.

Symptoms: Adverse symptoms may include the following: pain watering redness

Ingestion

Get medical attention immediately. Call a poison center or physician. Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Chemical burns must be treated promptly by a physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: Adverse symptoms may include the following: stomach pains

Immediate Medical Attention

Get medical attention immediately. Call a poison center or physician. Chemical burns must be treated promptly by a physician. If unconscious, place in recovery position and get medical attention immediately. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

None known.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Do not breathe vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. The spilled material may be neutralized with sodium carbonate, sodium bicarbonate or sodium hydroxide. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth.

Materials: water; inert dry material; non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not get in eyes or on skin or clothing. Do not breathe vapour or mist. Do not ingest. If during normal use the material presents a respiratory hazard, use only with adequate ventilation or wear appropriate respirator. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Keep away from alkalis. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Separate from alkalis. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled containers. Use appropriate containment to avoid environmental contamination. See Section 10 for incompatible materials before handling or use.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

If user operations generate dust, fumes, gas, vapour or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Wear suitable gloves tested to EN374. Impervious gloves (e.g. butyl, nitrile, etc.) are recommended if skin contact is possible and for processing operations. Protective gloves must meet the standards in accordance with CEN EN374, ASTM F1001 or international equivalent.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles and/or face shield. If inhalation hazards exist, a full-face respirator may be required instead. Recommended: safety glasses with side-shields Use eye protection according to EN 166.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Use appropriate containment to avoid environmental contamination. Keep container closed. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Dispose of waste in accordance with environmental legislation.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Boiling Point
Not relevant/applicable due to nature of the product.
Odor
Not relevant/applicable due to nature of the product.
Voc Content
---
Physical State Data
liquid
Molecular Weight
Not relevant/applicable due to nature of the product.
Melting Point
Not relevant/applicable due to nature of the product.
Crystallisation Point
---
Solubility In Fat
---
Odor Threshold
Not relevant/applicable due to nature of the product.
Appearance
---
Solubility In Water
Not relevant/applicable due to nature of the product.
Auto Ignition Temperature
Not relevant/applicable due to nature of the product.
Colour Intensity
---
Dynamic Viscosity
---
State Under Standard Conditions
---
Relative Density
1.0007
Vapor Pressure
Not relevant/applicable due to nature of the product.
Softening Point
Not relevant/applicable due to nature of the product.
Metal Corrosion
---
Density
Not relevant/applicable due to nature of the product.
Flammability
Not relevant/applicable due to nature of the product.
Cloud Point
---
Relative Evaporation Rate
---
Form
---
Properties Status
---
Kinematic Viscosity
Not relevant/applicable due to nature of the product.
Partition Coefficient
Not relevant/applicable due to nature of the product.
Lower Explosive Limit
Not relevant/applicable due to nature of the product.
Evaporation Rate
Not relevant/applicable due to nature of the product.
Upper Explosive Limit
Not relevant/applicable due to nature of the product.
Explosive Limits
---
Ph
2 [Conc. (% w/w): 6.4%]
Bulk Density
---
Colour
Colourless.
Physical State
Liquid.
Solidification Point
---
Decomposition Temperature
Not relevant/applicable due to nature of the product.
Vapor Density
---
Flash Point
[Product does not sustain combustion.]
Freezing Point
Not relevant/applicable due to nature of the product.
Solubility
Miscible with water
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

No specific data.

Incompatible

Attacks many metals producing extremely flammable hydrogen gas which can form explosive mixtures with air. Reactive or incompatible with the following materials: alkalis

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimised wherever possible.

Disposal

Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and nonrecyclable products via a licensed waste disposal contractor.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
No.
Shipping Name
Not regulated.
Transport Class
Not regulated.
Packing Group
Not regulated.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Atellica™ CH Conditioner?

The signal word is danger.

What is the physical form of Atellica™ CH Conditioner?

Atellica™ CH Conditioner is a liquid. with colourless. color. It has not relevant/applicable due to nature of the product. odor.

What is the solubility of Atellica™ CH Conditioner?

Miscible with water

What is Atellica™ CH Conditioner used for?

Diagnostic agents.

What are the hazard statements for Atellica™ CH Conditioner?

This substance has 1 hazard statement:

  • H318: Causes serious eye damage.

What is the melting point of Atellica™ CH Conditioner?

The melting point is Not relevant/applicable due to nature of the product. and the boiling point is Not relevant/applicable due to nature of the product..