NextSDS Logo
Safety Data Sheet EN

ELATUR® CH

CAS 166412-78-8
EC 431-890-2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ELATUR® CH

Regulatory Identifiers

CAS Number
166412-78-8 Check regulations →
EC Number
431-890-2 Check regulations →
REACH No.
01-0000017810-74

Identified Uses

Plasticizer, Construction chemicals, Raw materials for coatings, Lubricant, Adhesives

Manufacturers & Suppliers

W

Will & Co. B.V.

manufacturer

Dellaertlaan 24, 1171 HG Badhoevedorp, Netherlands

+31 20 659 75 01

Emergency Contacts

The National Poisons Information Service, Birmingham

(+44) (0)121 507 4123

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Cyclohexane-1,2-dicarboxylic acid, diisononyl ester EC: 431-890-2 166412-78-8 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Take affected persons into fresh air and keep quiet. Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

Eye contact

Make sure to remove any contact lenses from the eyes before rinsing. Rinse opened eye for several minutes under running water. Seek medical treatment. Protect unharmed eye.

Ingestion

If affected person is conscious: Rinse mouth with water. Seek immediate medical advice.

Immediate Medical Attention

Seek immediate medical advice.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Unsuitable media

Water with full jet

Specific hazards

Carbon monoxide (CO), Carbon dioxide (CO2).

Instructions

Cool endangered receptacles with water spray.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with the eyes and skin. Wear protective equipment. Keep unprotected persons away. Ensure adequate ventilation

Environmental

Do not allow product to reach sewage system or any water course.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Pick up mechanically. Fill into labelled, sealable containers.

Materials: liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use personal protection equipment. Avoid contact with skin, eyes or clothing.

Storage

Store only in the original receptacle. Store in a cool location. Store under clean dry conditions. Keep container tightly sealed.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Chemicals-resistant protection gloves towards DIN EN 374. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

Use suitable respiratory protective device in case of insufficient ventilation. Filter A/P2

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colourless
Colour
Colourless
Colour Intensity
---
Form
Liquid
Odor
Nearly odourless
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Undetermined.
Boiling Point
394 °C
Flash Point
224 °C
Freezing Point
-54 °C
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
<0.00001 hPa
Vapor Density
---
Relative Density
0.95 g/cm³
Bulk Density
---
Density
0.95 g/cm³
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
330 °C
Decomposition Temperature
>278 °C
Solubility
---
Partition Coefficient
10 log POW
Solubility In Water
<0.02 mg/L
Solubility In Fat
---
Molecular Weight
424.66 g/Mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
52.24 mPa·s
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Hazardous reactions

Reacts with strong oxidizing agents.

Avoid

To avoid thermal decomposition do not overheat. No further relevant information available.

Incompatible

Strong oxidizing agents

Decomposition

Carbon monoxide and carbon dioxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ELATUR® CH?

The signal word is no signal word.

What is the physical form of ELATUR® CH?

ELATUR® CH is a liquid appearing as colourless with colourless color. It has nearly odourless odor.

What is ELATUR® CH used for?

Plasticizer, Construction chemicals, Raw materials for coatings, Lubricant, Adhesives

What is the melting point of ELATUR® CH?

The melting point is Undetermined. and the boiling point is 394 °C.