NextSDS Logo
Safety Data Sheet EN

Sivex Filters

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Sivex Filters
Product Code
05002 - SVX

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Ceramic foam filter.

Uses advised against

Not fit for use in anything related to human consumption.

Manufacturers & Suppliers

P

Pyrotek CZ, s.r.o.

Prazska 5, 678 01 Blansko, Czech Republic

(420) (0)516-428-111

P

Pyrotek Inc

9503 E. Montgomery Avenue, Spokane Valley, WA 99206 USA

(509) 926-6212

Emergency Contacts

Chemtrec North America

(800) 424-9300

Chemtrec Outside North America

+1 703 527 3887

Europe

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Aluminium phosphate EC: 232-056-9 7784-30-7 10 - 30% No
Aluminum Oxide EC: 215-691-6 1344-28-1 70% No
Bentonite EC: 215-108-5 1302-78-9 0.5 - 1.5% No

Notes

This product may be used with a gasket. Please refer to the appropriate SDS sheet for information.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms persist, call a physician.

Skin contact

Wash off with soap and water. If skin irritation persists, call a physician.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If symptoms persist, call a physician.

Ingestion

Not a normal route of exposure. Consult a physician if necessary.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding fire

Unsuitable media

None known.

Specific hazards

None known

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand and complete protective equipment for fire-fighting as per European standard EN 469

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment.

Environmental

No information available.

Cleanup methods

Soak up with inert absorbent material

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid dust formation

Storage

Keep in a dry, cool and well-ventilated place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Mechanical ventilation and local exhaust is recommended.

Hands

Protective gloves.

Eyes

In case of dust, use: Tightly fitting safety goggles.

Respiratory

Respiratory protection is not necessary for normal handling of material which does not release dust. If exposure limits are exceeded or irritation is experienced, the user must determine if any locally approved respiratory protection must be worn. Positive-pressure supplied air respirators may be required for high airborne contaminant concentrations.

Skin/Body

Long sleeved clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
---
Physical State
Solid
Solubility
---
Relative Evaporation Rate
---
Colour
Cream
Crystallisation Point
---
Cloud Point
---
Partition Coefficient
Not Determined
Ph
Not Applicable
Freezing Point
>1200 °C
Bulk Density
---
Odor Threshold
---
Density
---
Metal Corrosion
---
Melting Point
>1200 °C
Decomposition Temperature
---
Molecular Weight
---
State Under Standard Conditions
---
Form
---
Flammability
---
Appearance
Foam
Voc Content
---
Solidification Point
---
Vapor Density
---
Physical State Data
solid
Flash Point
---
Evaporation Rate
---
Lower Explosive Limit
---
Odor
Odourless
Boiling Point
Not determined
Softening Point
---
Properties Status
---
Relative Density
---
Explosive Limits
---
Solubility In Water
Insoluble in water
Vapor Pressure
Not determined
Auto Ignition Temperature
Not determined
Dynamic Viscosity
---
Kinematic Viscosity
---
Solubility In Fat
---
Colour Intensity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable.

Hazardous reactions

Hazardous polymerization does not occur.

Avoid

Avoid dust formation

Incompatible

Water. Exposure to moisture.

Decomposition

No dangerous reaction known under conditions of normal use.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Sivex Filters?

The signal word is no signal word.

What is the physical form of Sivex Filters?

Sivex Filters is a solid appearing as foam with cream color. It has odourless odor.

What is Sivex Filters used for?

Ceramic foam filter.

What is the melting point of Sivex Filters?

The melting point is >1200 °C and the boiling point is Not determined.

Compliance Scanner