NextSDS Logo
UN

UNICUT MF-Spezial Frsen

NO SIGNAL WORD Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
UNICUT MF-Spezial Frsen
Product Code
37100

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Metal working lubricant for minimum lubrication

Overview

UNICUT MF-Spezial Frsen is a liquid, dark yellow substance commonly used metal working lubricant for minimum lubrication.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Void)

Hazard Classifications

Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P273: Avoid release to the environment.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

UNICUT Wahl GmbH company logo - Safety Data Sheet supplier organization

UNICUT Wahl GmbH

manufacturer

๐Ÿ“

Feld-Vorstmann-Str. 14 D-56170 Bendorf / Rh

๐ŸŒ

DE

๐Ÿ“ 

0049 (0) 2622 / 2603

๐ŸŒ www.unicut-wahl.de

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

0049 (0) 2622 / 4266

๐ŸŒ

DE

๐Ÿ•’

Mon-Thu: 8.30 a.m. - 4:30 p.m Fri: 8:30 a.m. - 12:30 p.m.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Fatty alcohol derivates with AW-and EP-additves

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Talgalkylamin ethoxylat 61791-26-2 0.1-0.5% โš ๏ธ Hazardous

Additional Information

For the wording of the listed hazard phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting; call for medical help immediately.

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Liquid, Dark yellow
๐ŸŽจ Colour
Dark yellow
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
0 C
Critical Property
๐Ÿ’จ Boiling Point
324 C
Critical Property
๐Ÿ”ฅ Flash Point
190 C
Critical Property
๐Ÿ“Š Freezing Point
0 C
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
1 hPa
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0.85 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Product is not selfigniting.
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
n-octanol/water: Not determined.
๐Ÿ“Š Solubility In Water
Not miscible or difficult to mix.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
32 mm/s
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see item 7.

๐Ÿงค Hand Protection

Oil resistant gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Nitrile rubber, NBR. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact gloves made of the following materials are suitable: Nitrile rubber, NBR.

๐Ÿ‘๏ธ Eye Protection

Goggles recommended during refilling

๐Ÿ˜ท Respiratory Protection

Not required.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for UNICUT MF-Spezial Frsen?

The signal word for this substance is "no signal word".

What is the physical form of UNICUT MF-Spezial Frsen?

UNICUT MF-Spezial Frsen is a liquid appearing as liquid, dark yellow with dark yellow color. It has characteristic odor.

What is UNICUT MF-Spezial Frsen used for?

Metal working lubricant for minimum lubrication

What are the hazard statements for UNICUT MF-Spezial Frsen?

This substance has 1 hazard statements: H412: Harmful to aquatic life with long lasting effects.

What is the melting point of UNICUT MF-Spezial Frsen?

The melting point is 0 C and the boiling point is 324 C.