Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SIGMACOVER 295 HARDENER
- Product Form
- Liquid.
- Product Code
- 00249256
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Professional applications, Used by spraying. Coating.; Hardener.
Uses advised against
Product is not intended, labelled or packaged for consumer use.
Manufacturers & Suppliers
PPG Coatings Belgium BV/SRL
undefined
Tweemontstraat 104 B-2100 Deurne Belgium
+32-33606311
Emergency Contacts
Supplier
+31 20 4075210
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section. Xylene: Several REACH registrations cover the REACH registered substance with xylene isomers, ethylbenzene (and toluene). The other REACH Registrations include: 01-2119555267-33 reaction mass of ethylbenzene and m-xylene and p- xylene, 01-2119486136-34 Aromatic hydrocarbons, C8, 01-2119539452-40 reaction mass of ethylbenzene and xylene.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| xylene EC: 215-535-7 | 1330-20-7 | 25 - 49% | Yes |
| Fatty acids, C18-unsatd., dimers, oligomeric reaction products with fatty acids, C16-18 and C18-unsatd., branched and linear and triethylenetetramine EC: 500-381-8 | 157707-72-7 | 10 - 25% | Yes |
| N/A | --- | 5 - 8.7% | Yes |
| 2-methylpropan-1-ol EC: 201-148-0 | 78-83-1 | 5 - 10% | Yes |
| 1-methoxy-2-propanol EC: 203-539-1 | 107-98-2 | 5 - 9.6% | Yes |
| Amines, polyethylenepoly-, triethylenetetramine fraction EC: 292-588-2 | 90640-67-8 | 0.3% | Yes |
| toluene EC: 203-625-9 | 108-88-3 | 0.3% | Yes |
Occupational exposure limits, if available, are listed in Section 8. SUB codes represent substances without registered CAS Numbers.
Notes
Prolonged or repeated contact may dry skin and cause irritation.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.
Symptoms: May cause respiratory irritation. Adverse symptoms may include respiratory tract irritation, coughing.
Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognised skin cleanser.
Symptoms: Causes skin irritation. Defatting to the skin. Adverse symptoms may include pain or irritation, redness, dryness, cracking, blistering may occur.
Check for and remove any contact lenses. Immediately flush eyes with running water for at least 15 minutes, keeping eyelids open. Seek immediate medical attention.
Symptoms: Causes serious eye damage. Adverse symptoms may include pain, watering, redness.
If swallowed, seek medical advice immediately and show the container or label. Keep person warm and at rest. Do NOT induce vomiting.
Symptoms: No known significant effects or critical hazards. Adverse symptoms may include stomach pains.
Immediate Medical Attention
Seek immediate medical attention for eye contact or if swallowed. In case of inhalation of decomposition products in a fire, symptoms may be delayed; the exposed person may need to be kept under medical surveillance for 48 hours.
Medical Treatment
No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical,CO₂,water spray (fog) or foam.
Do not use water jet.
Flammable liquid and vapour. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. This material is harmful to aquatic life with long lasting effects. Fire water contaminated with this material must be contained and prevented from being discharged to any waterway, sewer or drain.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to British standard BS EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Do not breathe vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product. Note: see Section 1 for emergency contact information and Section 13 for waste disposal. Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). Water polluting material. May be harmful to the environment if released in large quantities.
Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container.
Materials: non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth; inert dry material
Related Substances
Similar chemicals with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Do not get in eyes or on skin or clothing. Do not breathe vapour or mist. Do not ingest. Avoid release to the environment. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges. Empty containers retain product residue and can be hazardous. Do not reuse container.
Store between the following temperatures: 0 to 35°C (32 to 95°F). Store in accordance with local regulations. Store in a segregated and approved area. Store in original container protected from direct sunlight in a dry, cool and wellventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Eliminate all ignition sources. Separate from oxidising materials. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled containers. Use appropriate containment to avoid environmental contamination.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures. Materials such as cleaning rags, paper wipes and protective clothing, which are contaminated with the product may spontaneously self-ignite some hours later. To avoid the risks of fires, all contaminated materials should be stored in purpose-built containers or in metal containers with tight-fitting, self-closing lids. Contaminated materials should be removed from the workplace at the end of each working day and be stored outside.
Store and use away from heat, sparks, open flame or any other ignition source. Materials such as cleaning rags, paper wipes and protective clothing, which are contaminated with the product may spontaneously self-ignite some hours later. To avoid the risks of fires, all contaminated materials should be stored in purpose-built containers or in metal containers with tight-fitting, self-closing lids. Contaminated materials should be removed from the workplace at the end of each working day and be stored outside.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
For prolonged or repeated handling, use the following type of gloves: May be used: nitrile rubber Recommended: polyvinyl alcohol (PVA), Viton, butyl rubber Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time greater than 480 minutes according to EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment.
Chemical splash goggles and face shield.
Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Wear a respirator conforming to EN140. Filter type: organic vapour (Type A) and particulate filter P3
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
When exposed to high temperatures may produce hazardous decomposition products.
oxidising agents, strong alkalis, strong acids.
carbon oxides nitrogen oxides
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimised wherever possible.
Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and nonrecyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1263
- Shipping Name
- PAINT RELATED MATERIAL
- Transport Class
- 3
- Packing Group
- III
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SIGMACOVER 295 HARDENER?
The signal word is danger.
What is the physical form of SIGMACOVER 295 HARDENER?
SIGMACOVER 295 HARDENER is a liquid. with colourless. color. It has amine-like. [strong] odor.
What is the solubility of SIGMACOVER 295 HARDENER?
insoluble in water.
What is SIGMACOVER 295 HARDENER used for?
Professional applications, Used by spraying. Coating.; Hardener.
What are the hazard statements for SIGMACOVER 295 HARDENER?
This substance has 5 hazard statements:
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H412: Harmful to aquatic life with long lasting effects.