01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE C 511 96SC 3C 0.23MM GN

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Solder Wire

Manufacturers & Suppliers

H

Henkel Belgium N.V.

Esplanade 1 1020 Brussels Belgium

+32 (2) 421 2711

Emergency Contacts

Emergency Contact

+44 (0)1442 278497

24 Hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Tin EC: 231-141-8 7440-31-5 90 - 100% Yes
Silver EC: 231-131-3 7440-22-4 1 - 5% Yes

Notes

For full text of the H - statements and other abbreviations see section 16 "Other information". Substances without classification may have community workplace exposure limits available.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms persist, seek medical advice.

Symptoms: Flux fumes may irritate the nose, throat and lungs and may after prolonged/repeated exposure give an allergic reaction (asthma).

Skin contact

Rinse with running water and soap. Obtain medical attention if irritation persists.

Eye contact

Flush eyes with plenty of water for at least 5 minutes. If irritation persists seek medical attention.

Ingestion

Do not induce vomiting. Seek medical advice.

Immediate Medical Attention

If symptoms persist, seek medical advice. Obtain medical attention if irritation persists. Seek medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide, foam, powder Fine water spray

Unsuitable media

Do not use water on fires where molten metal is present.

Specific hazards

High temperatures may produce heavy metal dust, fumes or vapours. The flux medium will give rise to irritating fumes.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment.

Environmental

Do not empty into drains / surface water / ground water.

Cleanup methods

Scrape up spilled material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid skin and eye contact.

Storage

Ensure good ventilation/extraction. Store in a cool, dry place.

Hygiene

When using do not eat, drink or smoke. Wash hands before breaks and immediately after handling the product. Good industrial hygiene practices should be observed. Do not eat, drink or smoke while working. After handling solder wash hands with soap and water before eating, drinking or smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Extraction is necessary to remove fumes evolved during reflow. Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction. Ensure good ventilation/extraction.

Hands

Chemical-resistant protective gloves (EN 374). Suitable materials for short-term contact or splashes (recommended: at least protection index 2, corresponding to > 30 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) Suitable materials for longer, direct contact (recommended: protection index 6, corresponding to > 480 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) This information is based on literature references and on information provided by glove manufacturers, or is derived by analogy with similar substances. Please note that in practice the working life of chemical-resistant protective gloves may be considerably shorter than the permeation time determined in accordance with EN 374 as a result of the many influencing factors (e.g. temperature). If signs of wear and tear are noticed then the gloves should be replaced.

Eyes

Safety glasses with sideshields or chemical safety goggles should be worn if there is a risk of splashing.

Respiratory

Ensure adequate ventilation. An approved mask or respirator fitted with an organic vapour cartridge should be worn if the product is used in a poorly ventilated area In case of aerosol formation, we recommend wearing of appropriate respiratory protection equipment with ABEK P2 filter. This recommendation should be matched to local conditions.

Skin/Body

Wear suitable protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Boiling Point
No data available / Not applicable
Auto Ignition Temperature
No data available / Not applicable
Form
---
Solubility
Insoluble (Solvent: Water)
Molecular Weight
---
Relative Evaporation Rate
---
Lower Explosive Limit
---
Solubility In Fat
---
Physical State Data
solid
Odor
---
Cloud Point
---
Solidification Point
No data available / Not applicable
Decomposition Temperature
No data available / Not applicable
Flammability
No data available / Not applicable
Vapor Density
No data available / Not applicable
Partition Coefficient
No data available / Not applicable
Crystallisation Point
---
Upper Explosive Limit
---
Melting Point
218 - 227 °C (424.4 - 440.6 °F), 217 °C (422.6 °F)
Relative Density
---
Vapor Pressure
Not applicable
Evaporation Rate
No data available / Not applicable
Softening Point
---
Explosive Limits
---
Density
7,5 g/cm3
Odor Threshold
No data available / Not applicable
Properties Status
---
State Under Standard Conditions
---
Flash Point
---
Freezing Point
---
Bulk Density
No data available / Not applicable
Appearance
solid material grey
Solubility In Water
Insoluble
Metal Corrosion
---
Kinematic Viscosity
No data available / Not applicable
Colour Intensity
---
Voc Content
---
Colour
grey
Physical State
solid material
Ph
Not applicable
Dynamic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Solder alloy will react with concentrated nitric acid to produce toxic fumes of nitrogen oxides.

Hazardous reactions

See section reactivity

Avoid

No decomposition if stored and applied as directed.

Incompatible

None if used properly.

Decomposition

Thermal decomposition can lead to release of irritating gases and vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE C 511 96SC 3C 0.23MM GN?

The signal word is no signal word.

What is the physical form of LOCTITE C 511 96SC 3C 0.23MM GN?

LOCTITE C 511 96SC 3C 0.23MM GN is a solid material appearing as solid material grey with grey color.

What is the solubility of LOCTITE C 511 96SC 3C 0.23MM GN?

Insoluble (Solvent: Water)

What is LOCTITE C 511 96SC 3C 0.23MM GN used for?

Solder Wire

What is the melting point of LOCTITE C 511 96SC 3C 0.23MM GN?

The melting point is 218 - 227 °C (424.4 - 440.6 °F), 217 °C (422.6 °F) and the boiling point is No data available / Not applicable.