NextSDS Logo
Safety Data Sheet EN

LOCTITE C 400 96SC 5C 0.5MM G known as 96SC C400 5C 0.5MM 0.25KG RLR

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE C 400 96SC 5C 0.5MM G known as 96SC C400 5C 0.5MM 0.25KG RLR

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Solder Wire

Manufacturers & Suppliers

H

Henkel Belgium N.V.

Esplanade 1 1020 Brussels Belgium

+32 (2) 421 2711

Emergency Contacts

Emergency Contact

+44 (0)1442 278497

24 Hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Solder materials

Chemical Name CAS Number Concentration Hazardous
Tin EC: 231-141-8 7440-31-5 50 - 100% Yes
Silver EC: 231-131-3 7440-22-4 1 - 5% Yes

Notes

For full text of the H - statements and other abbreviations see section 16 "Other information". Substances without classification may have community workplace exposure limits available.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms persist, seek medical advice.

Symptoms: Flux fumes may irritate the nose, throat and lungs and may after prolonged/repeated exposure give an allergic reaction (asthma).

Skin contact

Rinse with running water and soap. Obtain medical attention if irritation persists.

Symptoms: Prolonged or repeated contact may cause skin irritation.

Eye contact

Flush eyes with plenty of water for at least 5 minutes. If irritation persists seek medical attention.

Symptoms: Prolonged or repeated contact may cause eye irritation.

Ingestion

Do not induce vomiting. Seek medical advice.

Immediate Medical Attention

If symptoms persist, seek medical advice. If irritation persists seek medical attention. Obtain medical attention if irritation persists. Seek medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, extinguishing powder, carbon dioxide.

Unsuitable media

Do not use water on fires where molten metal is present.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin and eyes. Wear protective equipment. Ensure adequate ventilation.

Environmental

Do not empty into drains / surface water / ground water.

Cleanup methods

Scrape up spilled material and place in a closed container for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid skin and eye contact. Avoid breathing fumes given out during soldering.

Storage

Ensure good ventilation/extraction. Store in a cool, dry place.

Hygiene

When using do not eat, drink or smoke. Wash hands before breaks and immediately after handling the product. Good industrial hygiene practices should be observed. Do not eat, drink or smoke while working. After handling solder wash hands with soap and water before eating, drinking or smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Extraction is necessary to remove fumes evolved during reflow. Ensure adequate ventilation, especially in confined areas. Ensure good ventilation/extraction.

Hands

Chemical-resistant protective gloves (EN 374). Suitable materials for short-term contact or splashes (recommended: at least protection index 2, corresponding to > 30 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) Suitable materials for longer, direct contact (recommended: protection index 6, corresponding to > 480 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) This information is based on literature references and on information provided by glove manufacturers, or is derived by analogy with similar substances. Please note that in practice the working life of chemical-resistant protective gloves may be considerably shorter than the permeation time determined in accordance with EN 374 as a result of the many influencing factors (e.g. temperature). If signs of wear and tear are noticed then the gloves should be replaced.

Eyes

Safety glasses with sideshields or chemical safety goggles should be worn if there is a risk of splashing. Protective eye equipment should conform to EN166.

Respiratory

Ensure adequate ventilation. An approved mask or respirator fitted with an organic vapour cartridge should be worn if the product is used in a poorly ventilated area In case of aerosol formation, we recommend wearing of appropriate respiratory protection equipment with ABEK P2 filter (EN 14387). This recommendation should be matched to local conditions.

Skin/Body

Wear suitable protective clothing. Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
No data available / Not applicable
Odor Threshold
No data available / Not applicable
Physical State
solid
Lower Explosive Limit
No data available / Not applicable
Density
7,5 g/cm3
Voc Content
---
Kinematic Viscosity
No data available / Not applicable
Relative Density
---
Auto Ignition Temperature
No data available / Not applicable
Freezing Point
---
Crystallisation Point
---
Softening Point
---
Molecular Weight
---
State Under Standard Conditions
---
Solubility In Fat
---
Flammability
No data available / Not applicable
Evaporation Rate
No data available / Not applicable
Cloud Point
---
Ph
Not applicable
Melting Point
217 °C (422.6 °F)
Explosive Limits
---
Properties Status
---
Boiling Point
No data available / Not applicable
Dynamic Viscosity
---
Solubility In Water
Insoluble
Appearance
solid
Bulk Density
No data available / Not applicable
Odor
---
Colour Intensity
---
Solubility
Insoluble
Relative Evaporation Rate
---
Partition Coefficient
No data available / Not applicable
Vapor Pressure
Not applicable
Solidification Point
No data available / Not applicable
Decomposition Temperature
No data available / Not applicable
Flash Point
---
Colour
grey
Physical State Data
solid
Metal Corrosion
---
Form
---
Vapor Density
No data available / Not applicable
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Solder alloy will react with concentrated nitric acid to produce toxic fumes of nitrogen oxides.

Hazardous reactions

See section reactivity

Avoid

Stable under normal conditions of storage and use.

Incompatible

See section reactivity.

Decomposition

Thermal decomposition can lead to release of irritating gases and vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE C 400 96SC 5C 0.5MM G known as 96SC C400 5C 0.5MM 0.25KG RLR?

The signal word is no signal word.

What is the physical form of LOCTITE C 400 96SC 5C 0.5MM G known as 96SC C400 5C 0.5MM 0.25KG RLR?

LOCTITE C 400 96SC 5C 0.5MM G known as 96SC C400 5C 0.5MM 0.25KG RLR is a solid appearing as solid with grey color.

What is the solubility of LOCTITE C 400 96SC 5C 0.5MM G known as 96SC C400 5C 0.5MM 0.25KG RLR?

Insoluble

What is LOCTITE C 400 96SC 5C 0.5MM G known as 96SC C400 5C 0.5MM 0.25KG RLR used for?

Solder Wire

What is the melting point of LOCTITE C 400 96SC 5C 0.5MM G known as 96SC C400 5C 0.5MM 0.25KG RLR?

The melting point is 217 °C (422.6 °F) and the boiling point is No data available / Not applicable.

Compliance Scanner

Scan your compliance