Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Multi Solver
- Product Code
- 60106
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen) SU3: Industrial uses: Uses of substances as such or in preparations at industrial sites. SU21 Consumer uses: Private households / general public / consumers. PC 35 Washing and cleaning products (including solvent based products). PROC11: Non industrial spraying. PROC7: Industrial spraying. Application of the substance/mixture: Cleaner solvent
Manufacturers & Suppliers
Ropamate International BVBA
manufacturer
Rouwbergskens 3/2, B-2340, Beerse, Belgium
+32 (0)14 41 50 55
http://www.ropamate.com
Emergency Contacts
Emergency Contact
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Ingredients according to detergents guideline 648/2004/EC
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C9-C11, n-alkanes, isoalkanes, cyclics, <2% aromatics EC: 919-857-5 | --- | 75 - 100% | Yes |
| propan-2-ol EC: 200-661-7 | 67-63-0 | 10 - 25% | Yes |
| xylene (mix) EC: 215-535-7 | 1330-20-7 | 2.5 - 10% | Yes |
| carbon dioxide EC: 204-696-9 | 124-38-9 | 2.5 - 10% | Yes |
Ingredients according to detergents guideline 648/2004/EC: Aliphatic hydrocarbons ≥30%, Aromatic hydrocarbons <5%
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Generally the product does not irritate the skin.
Rinse opened eye for several minutes under running water. Then consult a doctor.
Do not induce vomiting; call for medical help immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water haze, fire-extinguishing powder, carbon dioxide, alcohol resistant foam.
Water with full jet.
Mount respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep unprotected persons away.
Do not allow product to reach sewage system or any water course. Do not allow to enter sewers/surface or ground water.
Do not flush with water or aqueous cleansing agents.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Open and handle receptacle with care.
Store in a cool location. Observe official regulations on storing packagings with pressurized containers. Keep receptacle tightly sealed. Do not seal receptacle gas tight. Store in cool, dry conditions in well-sealed receptacles. Protect from heat and direct sunlight.
Do not spray onto a naked flame or any incandescent material. Keep ignition sources away – Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Solvent resistant gloves. Wear gloves for the protection against chemicals according to EN 374. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR. Recommended thickness of the material: >0,5mm. Penetration time of glove material: For continuous contact we recommend gloves with breakthrough time of at least 240 minutes, with the preference given to a breakthrough time greater than 480 minutes. For short-term or splash guard we recommend the same. We are aware that suitable gloves that offer this level of protection may not be available. In that case, a shorter breakthrough time is acceptable as long as the procedures governing maintenance and timely replacement are followed. The thickness of the gloves is not a good measure of the resistance of the gloves against a chemical substance, because this depends on the exact composition of the material from which the gloves are made. The exact breakthrough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses. Tightly sealed goggles.
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Filter AX/P2. Use suitable respiratory protective device in case of insufficient ventilation. Filter A/P2
Use protective suit (EN-13034/6)
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
Must not be disposed together with household garbage.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Void
Warning: Gases
Warning: Gases
Warning: Gases
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Multi Solver?
The signal word is danger.
What is the physical form of Multi Solver?
Multi Solver is a aerosol. with according to product specification. color. It has characteristic. odor.
What is Multi Solver used for?
SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen) SU3: Industrial uses: Uses of substances as such or in preparations at industrial sites. SU21 Consumer uses: Private households / general public / consumers. PC 35 Washing and cleaning products (including solvent based products). PROC11: Non industrial spraying. PROC7: Industrial spraying. Application of the substance/mixture: Cleaner solvent
What are the hazard statements for Multi Solver?
This substance has 3 hazard statements:
- H222: Extremely flammable aerosol. Pressurized container: May burst if heated.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of Multi Solver?
The melting point is Undetermined. and the boiling point is 82 °C.