Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Türk's solution for leukocyte counting
- Product Code
- 109277
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- This product is a mixture. REACH Registration Number see section 3.
Identified Uses
In vitro diagnostic reagent, Reagent for analysis
Manufacturers & Suppliers
Merck KGaA
manufacturer
64271 Darmstadt, Germany
+49 6151 72-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Acetic acid solution.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| acetic acid | 64-19-7 | 1 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air.
wash off with plenty of water. Remove contaminated clothing.
rinse out with plenty of water with the eyelid held wide open. Call in ophthalmologist if necessary.
make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Not combustible.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapours, aerosols. Evacuate the danger area, observe emergency procedures, consult an expert.
No special precautionary measures necessary.
Dispose of properly. Clean up affected area.
Related Products
Similar products with comparable safety profiles
CytoLyt® Solution
---
ThinPrep® CytoLyt Solution
---
Papanicolaou's solution 3a polychromatic solution EA 31 for cytological cancer and cycle diagnosis
---
LeucoScreen Reagent 1
---
MULTITEST CD3/CD8/CD45/CD4 CE
---
Papanicolaou's solution 1a Harris' hematoxylin solution for cytological cancer and cycle diagnosis
---
Papanicolaou's solution 2a Orange G solution (OG 6) for cytological cancer and cycle diagnosis
---
CD4 PE-CY7 CE
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Observe label precautions.
Tightly closed. Store at +15°C to +25°C.
Change contaminated clothing. Wash hands after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
full contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. splash contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact).
Safety glasses
Not required; except in case of aerosol formation.
Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
See section 10.3
The generally known reaction partners of water.
no information available
no information available
no information available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Türk's solution for leukocyte counting?
The signal word is no signal word.
What is the physical form of Türk's solution for leukocyte counting?
Türk's solution for leukocyte counting is a liquid with blue color. It has of acetic acid odor.
What is Türk's solution for leukocyte counting used for?
In vitro diagnostic reagent, Reagent for analysis
What is the melting point of Türk's solution for leukocyte counting?
The melting point is No information available. and the boiling point is No information available..