Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- GM508 CultActive
- Product Form
- Mixture
- Product Code
- 4 GM 508CULT-active1
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
GM508 CultActive is a carbonate buffered reagent designed to investigate oocytes of patients with failed fertilization after previous Intracytoplasmatic Sperm Injection cycles.
Uses advised against
No additional information available.
Manufacturers & Suppliers
Gynemed GmbH & Co. KG
manufacturer
Lübecker Straße 9, D-23738 Lensahn, Germany
Emergency Contacts
Emergency Contact
+49 (0)4363 90 32 90
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ultrapure water EC: 231-791-2 | 7732-18-5 | 90% | No |
| Sodium Chloride EC: 231-598-3 | 7647-14-5 | 1% | No |
| Potassium Chloride EC: 231-211-8 | 7447-40-7 | 1% | No |
| Calcium chloride dihydrate | 10035-04-8 | 1% | Yes |
| Magnesium Sulphate Heptahydrate | 10034-99-8 | 1% | No |
| Sodium Pyruvate EC: 204-024-4 | 113-24-6 | 1% | No |
| Potassium Dihydrogen Phosphate EC: 231-913-4 | 7778-77-0 | 1% | No |
| Glucose anhydrous EC: 200-075-1 | 50-99-7 | 1% | No |
| Sodium lactate EC: 212-762-3 | 867-56-1 | 1% | No |
| Sodium Hydrogen Carbonate EC: 205-633-7 | 144-55-8 | 1% | No |
| EDTA-2Na | 6381-92-6 | 1% | Yes |
| Solution (NON-ESS AA) | --- | 1% | No |
| Solution (NON-ESS + ESS AA) | --- | 1% | No |
| Alanyl-Glutamine EC: 475-290-9 | 39537-23-0 | 1% | No |
| Ca-Ionophore A23187 EC: 258-084-1 | 52665-69-7 | 1% | No |
| Dimethyl sulphoxide (DM5O) | 67-68-5 | 1% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Assure fresh air breathing. Allow the victim to rest.
Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.
Rinse immediately with plenty of water for at least 15 minutes. Obtain medical attention if pain, blinking or redness persist.
Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam. Dry powder. Carbon dioxide. Water spray. Sand.
Do not use a heavy water stream.
Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire-fighting water from entering environment.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Ventilate area.
Prevent entry to sewers and public waters.
Collect spillage.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wash Hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour.
Keep only in the original container in a cool ventilated place away from direct (sun)light. Keep container closed when not in use. Do not freeze. Do not use after expiry date. The product can be safely used up to 7 days after opening the container when sterile conditions are maintained and the products are stored at 2-8°C. Content cannot be resterilized after opening.
Wash Hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle in accordance with good industrial hygiene and safety. Avoid all unnecessary exposure.
Wear protective gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to meet the specifications of EU-directive 89/686/EEC and the standard EN374 derived from it.
Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166 (EU).
Wear appropriate mask. Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Wear fire/flame resistant/retardant clothing. Complete suit protecting against chemicals, flame retardant antistatic protective clothing. The type of protection must be selected according to the concentration and volume of the dangerous substance at the specific workplace.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable for 6 months from date of manufacture.
No additional information available.
Not established.
Direct (sun)light. Extremely high or low temperatures.
Strong acids. Strong bases.
Carbon monoxide. Carbon dioxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for GM508 CultActive?
The signal word is no signal word.
What is the physical form of GM508 CultActive?
GM508 CultActive is a liquid appearing as transparant liquid with transparant color. It has odourless odor.
What is the solubility of GM508 CultActive?
Highly soluble in water.
What is GM508 CultActive used for?
GM508 CultActive is a carbonate buffered reagent designed to investigate oocytes of patients with failed fertilization after previous Intracytoplasmatic Sperm Injection cycles.
What is the melting point of GM508 CultActive?
The melting point is No data available and the boiling point is No data available.