NextSDS Logo
DE

DETECTEUR DE FUITES "PLUS" 400 ML

WARNING Aérosol contenant un gaz liquéfié SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DETECTEUR DE FUITES "PLUS" 400 ML
Product Code
0890 27

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
U86G-C0E3-E00E-RA1D

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Pénétrant. Utilisation professionnelle du produit
Uses Advised Against
Non applicable

Overview

DETECTEUR DE FUITES "PLUS" 400 ML commonly used pénétrant. utilisation professionnelle du produit.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Aerosol Category 3 H229

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H229: Récipient sous pression: peut éclater sous l’effet de la chaleur.

Precautionary Statements

  • P210: Tenir à l’écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d’inflammation. Ne pas fumer.
  • P251: Ne pas perforer, ni brûler, même après usage.
  • P410 + P412: Protéger du rayonnement solaire. Ne pas exposer à une température supérieure à 50 °C/ 122 °F.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Würth Belux N.V - S.A.

distributor

Everdongenlaan 29 2300 Turnhout

BE

+32 (0)14 44 55 66

+32 (0)14 44 55 67

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32 (0)70 245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Amides de coco, N-[(diméthylamino)-3 propyl]
EC: 268-771-8
68140-01-2 0.0002-0.0025% Hazardous
Dioxyde de carbone
EC: 204-696-9
124-38-9 1-10% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

déplacer à l'air frais.

Skin Contact

Laver à l'eau et au savon par précaution.

Eye Contact

Rincer les yeux à l'eau par mesure de précaution.

Ingestion/Swallowing

En cas d'ingestion, NE PAS faire vomir. Rincer soigneusement la bouche avec de l'eau.

Immediate Medical Attention Required

Faire appel à une assistance médicale si des symptômes apparaissent.

Medical Treatment

Effectuer un traitement symptomatique et d'appoint.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Eau pulvérisée, Mousse résistant à l'alcool, Dioxyde de carbone (CO2), Poudre chimique sèche

Unsuitable Extinguishing Media

Jet d'eau à grand débit

Specific Fire Hazards

Une exposition aux produits de combustion peut être dangereuse pour la santé. En cas de hausse de température, risque d'éclatement des récipients en raison de la pression de vapeur élevée.

Fire Fighting Instructions

Utiliser des moyens d'extinction appropriés aux conditions locales et à l'environnement proche. Les récipients fermés peuvent être refroidis par eau pulvérisée. Eloigner les contenants de la zone de feu si cela peut se faire sans risque. Évacuer la zone.

Firefighter Protection Equipment

Porter un appareil de protection respiratoire autonome pour la lutte contre l'incendie, si nécessaire. Utiliser un équipement de protection individuelle.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Suivez les conseils de manipulation (voir chapitre 7) et les recommandations en matière d'équipement de protection (voir chapitre 8).

Large Spill Procedures

Pour les déversements importants, installer des digues ou d'autres méthodes de confnement pour empêcher la propagation du produit. Si le produit endigué peut être pompé, entreposer le produit récupéré dans un récipient approprié.

Environmental Precautions

Éviter le rejet dans l'environnement. Éviter tout déversement ou fuite supplémentaire, si cela est possible en toute sécurité. Empêcher l’épandage sur une vaste zone (p. ex., par confinement ou par des barrières anti-huile). Retenir l'eau de lavage contaminée et l'éliminer.

Cleanup Methods

Enlever avec un absorbant inerte. Nettoyer les substances résiduelles du déversement à l'aide d'un absorbant approprié.

Cleanup Materials:

absorbant inerte; absorbant approprié

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Partition Coefficient
Non applicable
Kinematic Viscosity
Non applicable
Evaporation Rate
Non applicable
Bulk Density
Not available
Solubility In Fat
Not available
Physical State
Aérosol contenant un gaz liquéfié
Critical Property
Odor
caractéristique
Appearance
Not available
Voc Content
Not available
Melting Point
Donnée non disponible
Critical Property
Colour Intensity
Not available
Relative Density
Donnée non disponible
Freezing Point
Donnée non disponible
Properties Status
Not available
Upper Explosive Limit
12,6 % (v)
Crystallisation Point
Not available
Density
1,03 g/cm³
Critical Property
Lower Explosive Limit
2,6 % (v)
Vapor Pressure
Non applicable
Flammability
Non classé comme danger d'inflammabilité
State Under Standard Conditions
Not available
Auto Ignition Temperature
Donnée non disponible
Molecular Weight
Not available
Softening Point
Not available
Odor Threshold
Donnée non disponible
Solubility In Water
légèrement soluble
Vapor Density
Not available
Relative Evaporation Rate
Not available
Ph
9 (20 °C)
Cloud Point
Not available
Explosive Limits
Not available
Solubility
Not available
Decomposition Temperature
Donnée non disponible
Flash Point
113 °C
Critical Property
Solidification Point
Not available
Boiling Point
100 °C
Critical Property
Metal Corrosion
Not available
Physical State Data
aerosol
Form
Not available
Colour
incolore
Dynamic Viscosity
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

A manipuler conformément aux normes d'hygiène industrielle et aux consignes de sécurité, sur la base des résultats de l'évaluation de l'exposition du lieu de travail.

Tenir à l’écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d’inflammation.

Ne pas fumer.

Storage Conditions

Conserver dans un endroit frais et bien ventilé.

Stocker en tenant compte des législations nationales spécifiques.

Ne pas percer ou brûler même après usage.

Tenir au frais.

Protéger du rayonnement solaire.

General Hygiene Measures

Si une exposition aux produits chimiques est probable pendant l'utilisation typique, fournir des systèmes de nettoyage occulaire et des douches de sécurité proches du lieu de travail. Ne pas manger, ne pas boire et ne pas fumer pendant l'utilisation. Laver les vêtements contaminés avant de les remettre.

Fire Prevention Measures

Tenir à l’écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d’inflammation. Ne pas fumer.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Assurer une ventilation adéquate, surtout dans les endroits clos. Réduire au minimum les concentrations d'exposition au travail.

Hand Protection

Matériel: Caoutchouc nitrile Délai de rupture: 480 min Épaisseur du gant: 0,45 mm Ligne directrice: L'équipement doit être conforme à la norme EN NBN 374 Remarques: Le choix du type de gants de protection contre les produits chimiques doit être effectué en fonction de la concentration et de la quantité des substances dangereuses propres aux postes de travail. Dans le cas d'applications spéciales, il est recommandé de se renseigner auprès du fabricant de gants sur la résistance aux produits chimiques des gants de protection indiqués ci-dessus. Se laver les mains avant les pauses et à la fin de la journée de travail.

Eye Protection

Veillez à respecter toutes les exigences locales et/ou nationales applicables en sélectionnant des mesures de protection destinées à un travail spécifique. Porter les équipements de protection individuelle suivants: Lunettes de sécurité Veuillez toujours porter des lunettes de protection lorsqu'on ne peut exclure un risque de contact du produit avec les yeux par inadvertance. L'équipement doit être conforme à la norme EN NBN 166

Respiratory Protection

Si une ventilation locale par aspiration adéquate n'est pas disponible ou si l'évaluation de l'exposition démontre des expositions au-delà des lignes directrices recommandées, utiliser une protection respiratoire. L'équipement doit être conforme à la norme EN NBN 137 Appareil respiratoire autonome

Skin/Body Protection

Nettoyer soigneusement la peau après tout contact avec le produit.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stable dans des conditions normales.

Reactivity

Non classé comme danger de réactivité.

Hazardous Reactions

En cas de hausse de température, risque d'éclatement des récipients en raison de la pression de vapeur élevée. Peut réagir avec les agents oxydants forts.

Conditions to Avoid

Aucun(e) à notre connaissance.

Incompatible Materials

Oxydants

Hazardous Decomposition Products

On ne connaît pas de produits de décomposition dangereux.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Waste Treatment Methods

Eliminer le produit conformément à la réglementation locale en vigueur.

Product Disposal Recommendations

Eliminer le produit conformément à la réglementation locale en vigueur. Le code de déchet doit être attribué par l'utilisateur, si possible en accord avec les autorités responsables pour l'élimination des déchets.

Waste Classification Codes

16 05 04* gaz en récipients à pression (y compris les halons) contenant des substances dangereuses EWC
16 05 04* gaz en récipients à pression (y compris les halons) contenant des substances dangereuses EWC
15 01 10* emballages contenant des résidus de substances dangereuses ou contaminés par de tels résidus EWC
Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN 1950

Proper Shipping Name

AÉROSOLS

Transport Hazard Class

2

Packing Group

Non réglementé

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DETECTEUR DE FUITES "PLUS" 400 ML?

The signal word for this substance is "warning".

What is the physical form of DETECTEUR DE FUITES "PLUS" 400 ML?

DETECTEUR DE FUITES "PLUS" 400 ML is a aérosol contenant un gaz liquéfié with incolore color. It has caractéristique odor.

What is DETECTEUR DE FUITES "PLUS" 400 ML used for?

Pénétrant. Utilisation professionnelle du produit

What are the hazard statements for DETECTEUR DE FUITES "PLUS" 400 ML?

This substance has 1 hazard statements: H229: Récipient sous pression: peut éclater sous l’effet de la chaleur.

What is the melting point of DETECTEUR DE FUITES "PLUS" 400 ML?

The melting point is Donnée non disponible and the boiling point is 100 °C.