NextSDS Logo
We

Weller Pyropen Refill, 75 ml / 42g

DANGER samengeperst gas SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Weller Pyropen Refill, 75 ml / 42g
Product Code
No. T005 16 160 99 / 49

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
burning gas / Brenngas / gaz combustible / gas combustibile / O gs combustivel / brandstof gas / brnslegas / braendselsgas / brenngass / polttoaine kaasu / paliwo gazowe / kttegaasi / deggazes / Kuro dujos / vykurovaci plyn / gorivo plin / gaz

Overview

Weller Pyropen Refill, 75 ml / 42g commonly used burning gas / brenngas / gaz combustible / gas combustibile / o gs combustivel / brandstof gas / brnslegas / braendselsgas / brenngass / polttoaine kaasu / paliwo gazowe / kttegaasi / deggazes / kuro dujos / vykurovaci plyn / gorivo plin / gaz.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Flam. Gas Category 1 H220
Press. Gas (Comp.) H280

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS04 GHS Hazard Pictogram: Compressed gas hazard - Pressurized gases that may explode if heated

GHS04

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H220: Zeer licht ontvlambaar gas.
  • H280: Bevat gas onder druk; kan ontploffen bij verwarming.

Precautionary Statements

  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P377: Brand door lekkend gas: niet blussen, tenzij het lek veilig gedicht kan worden.
  • P381: Alle ontstekingsbronnen wegnemen als dat veilig gedaan kan worden.
  • P403: Op een goed geventileerde plaats bewaren.
  • P410 + P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 C/122 F.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Weller Tools GmbH

global supplier

๐Ÿ“

Carl-Benz-Strae 2 Germany-74354 Besigheim

๐ŸŒ

DE

๐Ÿ“ž

+49 7143 580-0

๐Ÿ“ 

+49 7143 580-108

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

GIZ Mainz

๐Ÿ“ž

+49 6131 - 19240

๐ŸŒ

DE

๐Ÿ—ฃ๏ธ

Languages: DE, EN, FR

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
opaan
EC: 200-827-9
74-98-6 10-25% โš ๏ธ Hazardous
Isobutne
EC: 200-857-2
75-28-5 25-50% โš ๏ธ Hazardous
butane substance with national workplace exposure limit(s) (AT, BE, BG, DE, DK, ET, FI, FR, GB, GR, HU, IE, IT, LV. PL, PT)
EC: 203-448-7
106-97-8 50-100% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Voor frisse lucht zorgen. Bij irritatie van de ademhalingswegen arts consulteren.

๐Ÿ–๏ธ Skin Contact

Na aanraking met de huid onmiddellijk wassen met veel water en zeep.

๐Ÿ‘๏ธ Eye Contact

Als het product in de ogen komt, direct bij geopende oogspleet met veel water minstens 5 minuten spoelen. Aansluitend oogarts consulteren.

๐Ÿšจ Immediate Medical Attention Required

Geen gegevens beschikbaar

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
samengeperst gas
Critical Property
๐Ÿ“Š Physical State Data
gas
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
kleurloos
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
karakteristiek
๐Ÿ“Š Odor Threshold
niet bepaald
๐Ÿงช Ph
niet bepaald
๐ŸงŠ Melting Point
niet bepaald
Critical Property
๐Ÿ’จ Boiling Point
-44 C
Critical Property
๐Ÿ”ฅ Flash Point
-97 C
Critical Property
๐Ÿ“Š Freezing Point
niet bepaald
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
niet bepaald
๐Ÿ’จ Vapor Pressure
2 - 3,5 bar
๐Ÿ“Š Vapor Density
niet bepaald
๐Ÿ“Š Relative Density
ca.0,56 g/cm
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
niet bepaald
๐Ÿ“Š Upper Explosive Limit
10,9 Vol-%
๐Ÿ“Š Lower Explosive Limit
1,5 Vol-%
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
365 C
๐Ÿ“Š Decomposition Temperature
niet bepaald
๐Ÿ’ง Solubility
niet bepaald
๐Ÿ“Š Partition Coefficient
niet bepaald
๐Ÿ“Š Solubility In Water
niet mengbaar
๐Ÿ“Š Solubility In Fat
niet bepaald
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
100%
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Geschikt materiaal: NBR (Nitrilrubber) EN374 vereiste eigenschappen: gasdicht Doordringtijd (maximale draagduur) >480 min Opmerking Beschermingshandschoenen tegen chemicalin moeten in hun uitvoering afhankelijk van de concentatie van de gevaarlijke en hoeveelheid speciaal voor de werkplek uitgekozen worden.

๐Ÿ‘๏ธ Eye Protection

Oogbescherming: niet vereist.

๐Ÿ˜ท Respiratory Protection

Adembescherming is noodzakelijk bij: onvoldoende ventilatie

๐ŸŒ Environmental Exposure Controls

Technische maatregelen ter voorkoming van blootstelling zie hoofdstuk 7. Er zijn geen overtreffende maatregelen noodzakelijk.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

2037

๐Ÿ“ฆ Proper Shipping Name

RECEPTACLES, SMALL, CONTAINING GAS

โš ๏ธ Transport Hazard Class

2

๐Ÿšข IMDG Maritime Transport Precautions

Limited Quantities (LQ) 120 ml

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Weller Pyropen Refill, 75 ml / 42g?

The signal word for this substance is "danger".

What is the physical form of Weller Pyropen Refill, 75 ml / 42g?

Weller Pyropen Refill, 75 ml / 42g is a samengeperst gas with kleurloos color. It has karakteristiek odor.

What is the solubility of Weller Pyropen Refill, 75 ml / 42g?

niet bepaald

What is Weller Pyropen Refill, 75 ml / 42g used for?

burning gas / Brenngas / gaz combustible / gas combustibile / O gs combustivel / brandstof gas / brnslegas / braendselsgas / brenngass / polttoaine kaasu / paliwo gazowe / kttegaasi / deggazes / Kuro dujos / vykurovaci plyn / gorivo plin / gaz

What are the hazard statements for Weller Pyropen Refill, 75 ml / 42g?

This substance has 2 hazard statements: H220: Zeer licht ontvlambaar gas. H280: Bevat gas onder druk; kan ontploffen bij verwarming.

What is the melting point of Weller Pyropen Refill, 75 ml / 42g?

The melting point is niet bepaald and the boiling point is -44 C.