SU3 Industriële toepassingen Uiteindelijke toepassingen van substanties als zodanig of preparaten op industriële lokaties SU22 Professionele toepassingen openbaar domein (overheid, onderwijs, entertainment, dienstverlening, vakmensen)

Manufacturers & Suppliers

V

VEIDEC

VEIDEC AB logo

VEIDEC AB

manufacturer

Videvågen 9, 247 64 Veberöd

+46 46 23 89 00

http://www.veidec.com

Emergency Contacts

Alarmnummer

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aerosol Cat. 1 H229

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H222 Zeer licht ontvlambare aerosol.
H229 Houder onder druk: kan open barsten bij verhitting.

Precautionary Statements

P102 Buiten het bereik van kinderen houden.
P210 Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
P211 Niet in een open vuur of op andere ontstekingsbronnen spuiten.
P251 Ook na gebruik niet doorboren of verbranden.
P410 + P412 Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 °C/122°F.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Butaan EC: 203-448-7 106-97-8 70 - 80% Yes
Isobutaan EC: 200-857-2 75-28-5 20 - 30% Yes
Propaan EC: 200-827-9 74-98-6 1% Yes

Notes

De volledige tekst voor alle R-zinnen en gevarenzinnen wordt weergegeven in Sectie 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frisse lucht.

Skin contact

Met water afspoelen.

Eye contact

Onmiddellijk met water uitspoelen.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Waternevel, poeder of CO2.

Unsuitable media

Gebruik bij het blussen van brand geen waterstraal, aangezien die de brand verspreidt.

Specific hazards

Bij sterke verhitting ontstaat overdruk, die kan leiden tot explosief openspringen van de spuitbus.

Instructions

Volg de algemene gedragsregels van het bedrijf op.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Geen advies gegeven.

Environmental

Niet naar riool, grond of aquatisch milieu afvoeren.

Cleanup methods

Geen advies gegeven.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Voor goede ventilatie zorgen. Maatregelen treffen tegen ontladingen van statische elektriciteit.

Storage

Spuitbussen: mogen niet worden blootgesteld aan direct zonlicht of aan temperaturen boven 50°C. In oorspronkelijke houder bewaren.

Fire prevention

Verwijderd houden van warmte/vonken/open vuur/hete oppervlakken. — Niet roken.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Onder normale omstandigheden zijn handschoenen niet nodig.

Respiratory

Onder normale omstandigheden is het gebruik van ademhalingsbescherming niet nodig.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Aerosol.
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
---
Colour
Kleurloos.
Colour Intensity
---
Form
---
Odor
Karakteristiek.
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
---
Flash Point
Waarde: -60 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Waarde: 3500 hPa
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
Waarde: 0,581 g/ml
Flammability
---
Upper Explosive Limit
Waarde: 1,5-8,5 Vol%
Lower Explosive Limit
Waarde: 1,5-8,5 Vol%
Explosive Limits
---
Auto Ignition Temperature
Waarde: 365 °C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
580 g/l
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabiel onder normale temperatuuromstandigheden en aanbevolen gebruik.

Reactivity

Er zijn geen specifieke omstandigheden die mogelijk leiden tot een gevaarlijke situatie.

Hazardous reactions

Geen gegevens vermeld.

Avoid

Aerosolbussen niet blootstellen aan hoge temperaturen of direct zonlicht.

Incompatible

Geen gegevens vermeld.

Decomposition

Geen onder normale omstandigheden.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
SPUITBUSSEN (AÉROSOLEN)
Transport Class
2.1
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Lighter Refill?

The signal word is danger.

What is the physical form of Lighter Refill?

Lighter Refill is a aerosol. with kleurloos. color. It has karakteristiek. odor.

What is Lighter Refill used for?

SU3 Industriële toepassingen Uiteindelijke toepassingen van substanties als zodanig of preparaten op industriële lokaties SU22 Professionele toepassingen openbaar domein (overheid, onderwijs, entertainment, dienstverlening, vakmensen)

What are the hazard statements for Lighter Refill?

This substance has 2 hazard statements:

  • H222: Zeer licht ontvlambare aerosol.
  • H229: Houder onder druk: kan open barsten bij verhitting.