Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Perfluorodecalin
Product Code
P9900

Regulatory Identifiers

CAS Number
306-94-5 Check regulations →
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma-Aldrich BVBA

manufacturer

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 3 899 1301

Emergency Contacts

CHEMTREC

+(32)28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Synonyms: Octadecafluorodecahydronaphthalene(cis+trans); Perfluorodecahydronaphthalene(cis+trans). Formula: C10F18. Molecular Weight: 462,08 g/mol. CAS-No.: 306-94-5. EC-No.: 206-192-4.

Chemical Name CAS Number Concentration Hazardous
Octadecafluorodecahydronaphthalene(cis+trans) EC: 206-192-4 306-94-5 --- No

Aldrich - P9900

Notes

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathedin,move personinto fresh air. If not breathing, give artificial respiration.

Skin contact

Wash offwithsoap and plentyofwater.

Eye contact

Flush eyes withwaterasa precaution.

Ingestion

Nevergive anything by mouth to an unconsciousperson.Rinsemouthwithwater.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Specific hazards

Carbon oxides, Hydrogen fluoride

Instructions

Wear self contained breathing apparatus for fire fighting if necessary.

Firefighter Protection

Wear self contained breathing apparatus for fire fighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid breathing vapours, mist or gas.

Environmental

Do not let product enter drains.

Cleanup methods

Keep in suitable, closed containers for disposal.

Materials: suitable, closed containers

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2. Handle and open container with care.

Storage

Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

General industrial hygiene practice.

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Full contact Material: Nitrile rubber Minimum layer thickness: 0,4 mm Break through time: 480 min Material tested:Camatril® (KCL 730 / Aldrich Z677442, Size M) Splash contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 120 min Material tested:Dermatril® (KCL 740 / Aldrich Z677272, Size M) > data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374 If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Respiratory

Respiratory protection not required. For nuisance exposures use type OV/AG (US) or type ABEK (EU EN 14387) respirator cartridges. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
clear, liquid
Colour
colourless
Colour Intensity
---
Form
clear, liquid
Odor
no data available
Odor Threshold
no data available
Ph
no data available
Melting Point
Melting point/range:-10°C - lit.
Boiling Point
142°C - lit.
Flash Point
> 100°C - closedcup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
no data available
Vapor Pressure
no data available
Vapor Density
15,95- (Air= 1.0)
Relative Density
1,908 g/cm3 at 25°C
Bulk Density
---
Density
---
Flammability
no data available
Upper Explosive Limit
no data available
Lower Explosive Limit
no data available
Explosive Limits
---
Auto Ignition Temperature
no data available
Decomposition Temperature
no data available
Solubility
---
Partition Coefficient
no data available
Solubility In Water
no data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommendedstorageconditions.

Reactivity

no data available

Hazardous reactions

no data available

Avoid

no data available

Incompatible

Strong oxidizing agents

Decomposition

Otherdecomposition products -no data available In the event of fire:seesection 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Perfluorodecalin?

The signal word is no signal word.

What is the physical form of Perfluorodecalin?

Perfluorodecalin is a liquid appearing as clear, liquid with colourless color. It has no data available odor.

What is Perfluorodecalin used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Perfluorodecalin?

The melting point is Melting point/range:-10°C - lit. and the boiling point is 142°C - lit..