Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CRC(NZ) Multilube
- Chemical Name
- Not Applicable
- Synonyms
- Not Available
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Application is by spray atomisation from a hand held aerosol pack Use according to manufacturer's directions.
Manufacturers & Suppliers
CRC Industries (CRC Industries New Zealand)
manufacturer
10 Highbrook Drive East Tamaki Auckland New Zealand
+64 9 272 2700
http://www.crc.co.nz
CRC Industries (CRC Industries New Zealand)
manufacturer
Emergency Contacts
NZ Poisons Centre
0800 764 766
NZ Emergency Services
111
CHEMWATCH EMERGENCY RESPONSE (24/7)
+64 800 700 112
CHEMWATCH EMERGENCY RESPONSE (24/7)
+61 3 9573 3188
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
See section below for composition of Mixtures
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Solvent | --- | 30 - 60% | No |
| lubricant | --- | 30 - 60% | No |
| butane | --- | 10 - 30% | No |
| propane | 74-98-6 | 10 - 30% | No |
Notes
Legend: 1. Classified by Chemwatch; 2. Classification drawn from CCID EPA NZ; 3. Classification drawn from Regulation (EU) No 1272/2008 - Annex VI; 4. Classification drawn from C&L " EU IOELVs available
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Lay patient down. Keep warm and rested. Prostheses such as false teeth, which may block airway, should be removed, where possible, prior to initiating first aid procedures.
Flush skin and hair with running water (and soap if available). Remove any adhering solids with industrial skin cleansing cream. DO NOT use solvents. Seek medical attention in the event of irritation.
Immediately hold the eyelids apart and flush the eye continuously for at least 15 minutes with fresh running water. Ensure complete irrigation of the eye by keeping eyelids apart and away from eye and moving the eyelids by occasionally lifting the upper and lower lids. Transport to hospital or doctor without delay. Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.
Immediate Medical Attention
Transport to hospital or doctor without delay (for eye contact). Seek medical attention in the event of irritation (for skin contact).
Medical Treatment
Patients with inadequate tidal volumes or poor arterial blood gases (pO2 50 mm Hg) should be intubated. Arrhythmias complicate some hydrocarbon ingestion and/or inhalation and electrocardiographic evidence of myocardial injury has been reported; intravenous lines and cardiac monitors should be established in obviously symptomatic patients. The lungs excrete inhaled solvents, so that hyperventilation improves clearance. Inhaled cardioselective bronchodilators (e.g. Alupent, Salbutamol) are the preferred agents, with aminophylline a second choice. Lavage is indicated in patients who require decontamination; ensure use of cuffed endotracheal tube in adult patients.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Small fire: Water spray, dry chemical or CO2. Large fire: Water spray or fog.
Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine bleaches, pool chlorine etc. as ignition may result
Alert Fire Brigade and tell them location and nature of hazard. May be violently or explosively reactive. Prevent, by any means available, spillage from entering drains or water course.
Firefighter Protection
Wear breathing apparatus plus protective gloves.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
See section 8
Clean up all spills immediately. Avoid breathing vapours and contact with skin and eyes. Wear protective clothing, impervious gloves and safety glasses. Shut off all possible sources of ignition and increase ventilation.
Clear area of personnel and move upwind. Alert Fire Brigade and tell them location and nature of hazard. May be violently or explosively reactive.
See section 12
Clean up all spills immediately.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
DO NOT allow clothing wet with material to stay in contact with skin. Avoid all personal contact, including inhalation. Wear protective clothing when risk of exposure occurs. Use in a well-ventilated area. Prevent concentration in hollows and sumps.
Keep dry to avoid corrosion of cans. Corrosion may result in container perforation and internal pressure may eject contents of can. Store in original containers in approved flammable liquid storage area. DO NOT store in pits, depressions, basements or areas where vapours may be trapped. No smoking, naked lights, heat or ignition sources. Keep containers securely sealed.
No smoking, naked lights, heat or ignition sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
CARE: Use of a quantity of this material in confined space or poorly ventilated area, where rapid build up of concentrated atmosphere may occur, could require increased ventilation and/or protective gear Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed engineering controls can be highly effective in protecting workers and will typically be independent of worker interactions to provide this high level of protection. The basic types of engineering controls are: Process controls which involve changing the way a job activity or process is done to reduce the risk. Enclosure and/or isolation of emission source which keeps a selected hazard "physically" away from the worker and ventilation that strategically "adds" and "removes" air in the work environment.
▶ Neoprene rubber gloves ▶ No special equipment needed when handling small quantities. ▶ OTHERWISE: ▶ For potentially moderate exposures: ▶ Wear general protective gloves, eg. light weight rubber gloves. ▶ For potentially heavy exposures: ▶ Wear chemical protective gloves, eg. PVC. and safety footwear. Recommended material(s) (CPI - Chemwatch Performance Index): NITRILE+PVC (A), HYPALON (B), NITRILE (B), NATURAL RUBBER (C), NEOPRENE (C), PVC (C).
▶ No special equipment for minor exposure i.e. when handling small quantities. ▶ OTHERWISE: For potentially moderate or heavy exposures: ▶ Safety glasses with side shields. ▶ NOTE: Contact lenses pose a special hazard; soft lenses may absorb irritants and ALL lenses concentrate them.
Type AX Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent). Where the concentration of gas/particulates in the breathing zone, approaches or exceeds the "Exposure Standard" (or ES), respiratory protection is required. Degree of protection varies with both face-piece and Class of filter; the nature of protection varies with Type of filter. Cartridge respirators should never be used for emergency ingress or in areas of unknown vapour concentrations or oxygen content. The wearer must be warned to leave the contaminated area immediately on detecting any odours through the respirator. Cartridge performance is affected by humidity.
See Hand protection below. See Other protection below.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Product is considered stable.
See section 7
Hazardous polymerisation will not occur. See section 7
Elevated temperatures. Presence of open flame. See section 7
See section 7
See section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Not Applicable
63 190 277 327 344 381 959
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is CRC(NZ) Multilube known by?
CRC(NZ) Multilube is also known as: Not Available
What is the hazard signal word for CRC(NZ) Multilube?
The signal word is danger.
What is the physical form of CRC(NZ) Multilube?
CRC(NZ) Multilube is a aerosol appearing as clear colourless odourless flammable liquid. supplied as an aerosol pack. contents under pressure. contains highly flammable hydrocarbon propellant. with colourless color. It has odourless odor.
What is CRC(NZ) Multilube used for?
Application is by spray atomisation from a hand held aerosol pack Use according to manufacturer's directions.
What are the hazard statements for CRC(NZ) Multilube?
This substance has 2 hazard statements:
- H222: Extremely flammable aerosol. Pressurized container: may burst if heated.