NextSDS Logo
Safety Data Sheet NL

SIGMA SILICATE MC SET

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SIGMA SILICATE MC SET
Product Form
Viskeuze vloeistof

Regulatory Identifiers

CAS Number
N/A
02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Ethanol 000064-17-5 1% Yes
Methanol 000067-56-1 1% Yes
Xyleen 001330-20-7 5 - 10% Yes
Tetraethylsilikaat 000078-10-4 1 - 5% Yes
Zinkpoeder 007440-66-6 30 - 60% Yes
1-Methoxy-2-propanol 000107-98-2 5 - 10% Yes
Trimethylboraat 000121-43-7 1% Yes
Propyleen-1-glycol-2-methylether 001589-47-5 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In de frisse lucht brengen. Bij ademhalingsmoeilijkheden arts waarschuwen.

Skin contact

Verontreinigde kleding uittrekken en laten reinigen. Overtollig materiaal met doek verwijderen, reinigen met een geschikt reinigingsmiddel en/of wassen met water en zeep.

Eye contact

Spoelen met veel schoon water gedurende 15 minuten. Ogen openhouden. Bij aanhoudende irritatie arts raadplegen.

Ingestion

Mond spoelen en water laten drinken. Geen braken opwekken. Onmiddellijk arts waarschuwen of naar ziekenhuis vervoeren.

Immediate Medical Attention

Bij ademhalingsmoeilijkheden arts waarschuwen. Bij aanhoudende irritatie arts raadplegen. Onmiddellijk arts waarschuwen of naar ziekenhuis vervoeren.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Verneveld water, kooldioxyde, poeder of schuim.

Unsuitable media

Geen waterstraal gebruiken.

Specific hazards

Bij brand kunnen koolstof- en siliciumoxiden ontstaan.

Firefighter Protection

In besloten ruimten persluchtmasker dragen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Verwijderen van alle personen die geen geschikte beschermingsmiddelen dragen.

Environmental

Mag niet geloosd worden in rioleringssystemen en op oppervlaktewateren.

Cleanup methods

opnemen met inert, absorberend materiaal

Materials: inert, absorberend materiaal

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Contact met de huid, ogen en ademhalingswegen vermijden.

Storage

Goed gesloten verpakkingen bewaren in een koele en goed geventileerde ruimte.

Fire prevention

Verwijderd houden van ontstekingsbronnen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

MINIMALE HOEVEELHEID TE VENTILEREN LUCHT DIE NODIG IS VOOR 1 LITER PRODUKT OM MAC TE BEREIKEN : 2194 M3/L; OM 10% OEG TE BEREIKEN : 76 M3/L. WERKOMGEVINGEN VEREISEN GEFORCEERD VENTILATIE, BEPERKTE NATUURLIJK VENTILATIE OF BEPERKTE VENTILATIE.

Hands

Nitrilrubber handschoenen

Eyes

Veiligheidsbril

Respiratory

Halfmasker filter A, Verse lucht halfmasker, Verse lucht volgelaatsmasker, Verse lucht kap

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Evaporation Rate
> 1
Softening Point
---
Ph
---
Decomposition Temperature
---
Crystallisation Point
---
Relative Density
---
Dynamic Viscosity
---
Odor
---
Melting Point
---
Form
---
Solubility In Fat
---
Appearance
---
Upper Explosive Limit
19,0 VOL.%
Freezing Point
---
Density
2,31 G/ML
State Under Standard Conditions
---
Lower Explosive Limit
1,0 VOL.%
Vapor Pressure
0,670 - 5,600 KPA
Cloud Point
---
Physical State
---
Vapor Density
> 1
Properties Status
---
Partition Coefficient
---
Colour Intensity
---
Solubility In Water
Fractioneel
Bulk Density
---
Flammability
---
Boiling Point
78 - 143 °C
Physical State Data
---
Metal Corrosion
---
Solubility
---
Kinematic Viscosity
---
Auto Ignition Temperature
> 270 °C
Flash Point
16 °C
Solidification Point
---
Voc Content
---
Odor Threshold
---
Molecular Weight
---
Explosive Limits
---
Colour
---
Relative Evaporation Rate
> 1
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

verbranden in een geschikte en goedgekeurde verbrandingsoven

Disposal

Afval verwerken volgens wettelijke voorschriften van locale-, provinciale-, en centrale overheid

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

15.1 EEG: SYMBOOL F, R-ZINNEN: Licht ontvlambaar. 15.2 INDELING VOLGENS CPR-RICHTLIJNEN KLASSE : K1. 15.3 BESLUIT AANWIJZING GEVAARLIJKE AFVALSTOFFEN: STOFNUMMER C.14 : 75,67 GEW.%, STOFNUMMER D.6 : 0,37 GEW.%

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SIGMA SILICATE MC SET?

The signal word is no signal word.